Guidance of cardiac pacemaker leads using real time 3D ultrasound: Feasibility studies

被引:4
作者
Smith, SW [1 ]
Booi, RC [1 ]
Light, ED [1 ]
Merdes, CL [1 ]
Wolf, PD [1 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
关键词
pacemaker implantation; two-dimensional array; volumetric ultrasound imaging;
D O I
10.1177/016173460202400205
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
We investigated the feasibility of the guidance of pacemaker lead implantation using the pacemaker lead stylet as an acoustic wave-guide combined with real time 3D ultrasound imaging. In one approach, with a 2.5 MHz transducer coupled to a stylet of a pacemaker lead, we used the stylet as a transmitter to track the vibrating tip in a 3D ultrasound scan. In another approach, we connected the stylet to a piezo-electric actuator vibrating in the range 0.5-5 kHz so that the tip of the stylet was imaged using the color Doppler feature of the real time 3D ultrasound scanner. In both approaches, tracking of the isolated stylet showed good accuracy. However, neither approach offered sufficient signal-to-noise ratio to detect the vibration within the lumen of an intact pacemaker lead.
引用
收藏
页码:119 / 128
页数:10
相关论文
共 18 条
  • [1] Real-time three-dimensional dobutamine stress echocardiography in assessment of ischemia: Comparison with two-dimensional dobutamine stress echocardiography
    Ahmad, M
    Xie, TR
    McCulloch, M
    Abreo, G
    Runge, M
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (05) : 1303 - 1309
  • [2] Localization of needle tip with color Doppler during pericardiocentesis: In vitro validation and initial clinical application
    Armstrong, G
    Cardon, L
    Vilkomerson, D
    Lipson, D
    Wong, J
    Rodriguez, LL
    Thomas, JD
    Griffin, BP
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2001, 14 (01) : 29 - 37
  • [3] BEYER B, 1984, MED BIOL ENG COMPUT, V22, P268
  • [4] Firek B, 2000, EUR HEART J, V21, P580
  • [5] ULTRASONIC STYLETS FOR NEEDLES AND CATHETERS
    MCDICKEN, WN
    ANDERSON, T
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1984, 10 (04) : L499 - L507
  • [6] Echocardiographic transponder-guided catheter ablation feasibility and accuracy
    Menz, V
    Vilkomerson, D
    Ren, JF
    Michele, JJ
    Schwartzman, D
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2001, 5 (02) : 203 - 209
  • [7] Locating a catheter transducer in a three-dimensional ultrasound imaging field
    Merdes, CL
    Wolf, PD
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2001, 48 (12) : 1444 - 1452
  • [8] A comparison of coupling horns for waveguides used in medical ultrasonics
    Nicholson, NC
    McDicken, WN
    [J]. ULTRASONICS, 1996, 34 (07) : 747 - 755
  • [9] Validation of real-time three-dimensional echocardiography for quantifying left ventricular volumes in the presence of a left ventricular aneurysm: In vitro and in vivo studies
    Qin, JX
    Jones, M
    Shiota, T
    Greenberg, NL
    Tsujino, H
    Firstenberg, MS
    Gupta, PC
    Zetts, AD
    Xu, Y
    Sun, JP
    Cardon, LA
    Odabashian, JA
    Flamm, SD
    White, RD
    Panza, JA
    Thomas, JD
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (03) : 900 - 907
  • [10] Ramaswami G, 1999, J ENDOVASC SURG, V6, P52, DOI 10.1583/1074-6218(1999)006<0052:AOLLAS>2.0.CO