Determination of acid phosphatase activity in a double injection flow system with electrochemical detection

被引:8
|
作者
Castanón-Fernández, J [1 ]
Fernández-Abedul, MT [1 ]
Costa-García, A [1 ]
机构
[1] Univ Oviedo, Dept Quim Fis & Analit, Asturias, Spain
关键词
acid phosphatase; double-injection; stopped-flow; FIA-ECD;
D O I
10.1016/S0003-2670(99)00772-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An enzyme assay for the measurement of total and prostatic acid phosphatase activity by flow injection analysis with electrochemical detection has been developed. The substrate (alpha-naphthyl phosphate) and enzyme are simultaneously injected to the system by means of a double injection valve. The alpha-naphtol produced after stopping the flow is amperometrically quantified. The calibration curve is linear from 0.01 to 1.3 u/l with a limit of detection of 0.006 u/l. Results were compared with that obtained spectrophotometrically. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:225 / 232
页数:8
相关论文
共 50 条
  • [21] Flow injection analysis determination of ascorbic acid with spectrofluorimetric detection
    Ensafi, AA
    Rezaei, B
    ANALYTICAL LETTERS, 1998, 31 (02) : 333 - 342
  • [22] Flow injection determination of sialic acid based on amperometric detection
    Marzouk, Sayed A. M.
    Haddow, Jody D.
    Amin, Amr
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 157 (02) : 647 - 653
  • [23] Determination of esterase activity by flow injection analysis with amperometric detection
    Takamura, K
    Fuse, T
    Kusu, F
    ANALYTICAL SCIENCES, 1996, 12 (02) : 343 - 347
  • [24] Potentiometric flow-injection system for determination of alkaline phosphatase in human serum
    Ogonczyk, Dominika
    Koncki, Robert
    ANALYTICA CHIMICA ACTA, 2007, 600 (1-2) : 194 - 198
  • [25] Flow injection electrochemical determination of apomorphine
    Garrido, JMPJ
    Delerue-Matos, C
    Borges, F
    Macedo, TRA
    Oliveira-Brett, AM
    ANALYTICAL LETTERS, 2003, 36 (10) : 2199 - 2210
  • [26] DETERMINATION OF L-ASCORBIC-ACID BY A FLOW-INJECTION ANALYSIS WITH COPPER(II)-MEDIATED ELECTROCHEMICAL DETECTION
    SANO, A
    KUWAYAMA, T
    FURUKAWA, M
    TAKITANI, S
    NAKAMURA, H
    ANALYTICAL SCIENCES, 1995, 11 (03) : 405 - 409
  • [27] DETERMINATION OF THE FREE FATTY-ACID CONTENT IN FATS AND OILS BY FLOW-INJECTION ANALYSIS WITH ELECTROCHEMICAL DETECTION
    TAKAMURA, K
    FUSE, T
    KUSU, F
    ANALYTICAL SCIENCES, 1995, 11 (06) : 979 - 982
  • [28] Process monitoring of acetic acid in Escherichia coli cultivation using electrochemical detection in a flow injection system
    Tang, XJ
    Tocaj, A
    Holst, O
    Johansson, G
    BIOTECHNOLOGY TECHNIQUES, 1997, 11 (09) : 683 - 687
  • [29] Simultaneous flow injection determination of ascorbic acid and cysteine using double flow cell
    Teshima, N
    Nobuta, T
    Sakai, T
    ANALYTICA CHIMICA ACTA, 2001, 438 (1-2) : 21 - 29
  • [30] Optimization of a flow injection system with amperometric detection for arsenic determination
    Lolic, Aleksandar
    Nikolic, Snezana
    Mutic, Jelena
    ANALYTICAL SCIENCES, 2008, 24 (07) : 877 - 880