Relevance of Swept-Source Anterior Segment Optical Coherence Tomography for Corneal Imaging in Patients With Flap-Related Complications After LASIK

被引:16
作者
Abdelazeem, Khaled [1 ,2 ]
Sharaf, Mohamed [1 ,2 ]
Saleh, Mohamed G. A. [1 ,2 ]
Fathalla, Ahmed M. [1 ,2 ]
Soliman, Wael [1 ,2 ]
机构
[1] Assiut Univ, Dept Ophthalmol, Fac Med, Assiut, Egypt
[2] Alforsan Eye Ctr, LASIK Unit, Assiut, Egypt
关键词
swept-source anterior segment optical coherence tomography; laser in situ keratomileusis; flap complications; IN-SITU KERATOMILEUSIS; SOURCE OCT; EYE; MANAGEMENT; MYOPIA; VIVO;
D O I
10.1097/ICO.0000000000001773
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the role of swept-source anterior segment optical coherence tomography (AS-OCT) in the diagnosis and management of laser in situ keratomileusis (LASIK) flap-related complications. Methods: This prospective study included 25 eyes with LASIK flap-related complications imaged using swept-source AS-OCT between February and August 2016 at Alforsan Eye Centre, Assiut, Egypt. The images were acquired using a 6-mm line scan. Results: Imaging of flap-related LASIK complications using ASOCT revealed specific and nonspecific findings. Of note, epithelial ingrowth appeared as highly reflective lesions below the LASIK flap in the form of islands, nests, or a continuous sheet with or without changes in the overlying flap. Macrostriae manifested as domeshaped irregularities on the stromal surface with regular overlying epithelium, whereas microstriae appeared as corrugations on the stromal surface with regular overlying epithelium. Less common complications included multiple flap macrostriae accompanied by a traumatic folded flap with a flap edge at the interface. Interface debris appeared as a highly reflective interface lesion with or without a surrounding reaction. One eye with a flap that was torn and lost intraoperatively showed epithelialization over a thin residual stroma underlying a contact lens with no stromal infiltration on the second postoperative day. AS-OCT was useful for the assessment of flap thickness and planning of the new flap thickness in the event of an incomplete cut. Conclusions: Swept-source AS-OCT is useful not only for diagnosis but also for management of eyes with LASIK flaprelated complications by allowing noninvasive, noncontact, realtime acquisition of cross-sectional AS images.
引用
收藏
页码:93 / 97
页数:5
相关论文
共 19 条
  • [1] Value of optical coherence tomography for anterior segment surgery
    Doors, Muriel
    Berendschot, Tos T. J. M.
    de Brabander, John
    Webers, Carroll A. B.
    Nuijts, Rudy M. M. A.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (07) : 1213 - 1229
  • [2] Esquenazi S, 1999, J REFRACT SURG, V15, P648
  • [3] Laser in situ keratomileusis: Literature review of a developing technique
    Farah, SG
    Azar, DT
    Gurdal, C
    Wong, J
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (07) : 989 - 1006
  • [4] Ultra high-speed swept source OCT imaging of the anterior segment of human eye at 200 kHz with adjustable imaging range
    Gora, Michalina
    Karnowski, Karol
    Szkulmowski, Maciej
    Kaluzny, Bartlomiej J.
    Huber, Robert
    Kowalczyk, Andrzej
    Wojtkowski, Maciej
    [J]. OPTICS EXPRESS, 2009, 17 (17): : 14880 - 14894
  • [5] Helmy SA, 1996, J REFRACT SURG, V12, P417
  • [6] OPTICAL COHERENCE TOMOGRAPHY
    HUANG, D
    SWANSON, EA
    LIN, CP
    SCHUMAN, JS
    STINSON, WG
    CHANG, W
    HEE, MR
    FLOTTE, T
    GREGORY, K
    PULIAFITO, CA
    FUJIMOTO, JG
    [J]. SCIENCE, 1991, 254 (5035) : 1178 - 1181
  • [7] MICROMETER-SCALE RESOLUTION IMAGING OF THE ANTERIOR EYE IN-VIVO WITH OPTICAL COHERENCE TOMOGRAPHY
    IZATT, JA
    HEE, MR
    SWANSON, EA
    LIN, CP
    HUANG, D
    SCHUMAN, JS
    PULIAFITO, CA
    FUJIMOTO, JG
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1994, 112 (12) : 1584 - 1589
  • [8] Corneal topography with high-speed swept source OCT in clinical examination
    Karnowski, Karol
    Kaluzny, Bartlomiej J.
    Szkulmowski, Maciej
    Gora, Michalina
    Wojtkowski, Maciej
    [J]. BIOMEDICAL OPTICS EXPRESS, 2011, 2 (09): : 2709 - 2720
  • [9] Management of long-standing partially torn and flipped laser in situ keratomileusis flaps
    Kim, Jin Sun
    Chung, Byunghoon
    Lee, Taekjune
    Kim, Woon Cho
    Kim, Tae-im
    Kim, Eung Kweon
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (02) : 464 - 467
  • [10] Knorz MC, 1996, J REFRACT SURG, V12, P575