共 49 条
CFD modeling of a pilot-scale countercurrent spray drying tower for the manufacture of detergent powder
被引:33
作者:
Ali, Muzammil
[1
]
Mahmud, Tariq
[1
]
Heggs, Peter John
[1
]
Ghadiri, Mojtaba
[1
]
Bayly, Andrew
[1
]
Ahmadian, Hossein
[2
]
de Juan, Luis Martin
[2
]
机构:
[1] Univ Leeds, Sch Chem & Proc Engn, Inst Particle Sci & Engn, Leeds LS2 9JT, W Yorkshire, England
[2] P&G Tech Ctr Ltd, Newcastle Upon Tyne, Tyne & Wear, England
关键词:
Countercurrent spray drying;
heat and mass transfer;
multiphase CFD modeling;
spray drying kinetics;
COMPUTATIONAL FLUID-DYNAMICS;
TURBULENT FLOWS;
MASS-TRANSFER;
DEPOSITION;
DRYER;
HEAT;
SIMULATION;
PATTERNS;
2D;
D O I:
10.1080/07373937.2016.1163576
中图分类号:
TQ [化学工业];
学科分类号:
0817 ;
摘要:
A steady-state, three-dimensional, multiphase computational fluid dynamics (CFD) modeling of a pilot-plant countercurrent spray drying tower is carried out to study the drying behavior of detergent slurry droplets. The software package ANSYS Fluent is employed to solve the heat, mass, and momentum transfer between the hot gas and the polydispersed droplets/particles using the Eulerian-Lagrangian approach. The continuous-phase turbulence is modeled using the differential Reynolds stress model. The drying kinetics is modeled using a single-droplet drying model, which is incorporated into the CFD code using user-defined functions (UDFs). Heat loss from the insulated tower wall to the surrounding is modeled by considering thermal resistances due to deposits on the inside surface, wall, insulation, and outside convective film. For the particle-wall interaction, the restitution coefficient is specified as a constant value as well as a function of particle moisture content. It is found that the variation in the value of restitution coefficient with moisture causes significant changes in the velocity, temperature, and moisture profiles of the gas as well as the particles. Overall, a reasonably good agreement is obtained between the measured and predicted powder temperature, moisture content, and gas temperature at the bottom and top outlets of the tower; considering the complexity of the spray drying process, simplifying assumptions made in both the CFD and droplet drying models and the errors associated with the measurements.
引用
收藏
页码:281 / 299
页数:19
相关论文
共 49 条