Effect of pore size and layers on filtration performance of coalescing filters with different wettabilities

被引:37
作者
Chen, Feng [1 ]
Ji, Zhongli [1 ]
Qi, Qiangqiang [1 ]
机构
[1] China Univ Petr, Coll Mech & Transportat Engn, Beijing Key Lab Proc Fluid Filtrat & Separat, Beijing 102249, Peoples R China
基金
中国国家自然科学基金;
关键词
Filtration; Aerosol; Pore size; Wettability; Coalescing filters; LIQUID AEROSOLS; VERTICAL FIBERS; DRAINAGE LAYER; PRESSURE-DROP; MIST;
D O I
10.1016/j.seppur.2018.03.004
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The effect of pore size on filtration performance of coalescing filters was investigated experimentally, using four oleophilic and three oleophobic glass-fiber filter materials. The filters were fabricated into sandwiches composed of a varying number of layers, each of the same filter materials. The results showed that both trend and extent of variation of the excess channel pressure drop with number of layers were dominated by the pore size. As the pore size decreased, the excess channel pressure drop exhibited the increasing, stable, and decreasing trends with increasing number of layers for oleophobic filters, respectively, while it kept growing with number of layers for oleophilic filters. The jump pressure drop controlled by liquid film was inversely proportional to the mean pore size, with an empirical fit equation established to allow quantitative analysis of relationship between film thickness and mean pore size for oleophilic filters. The pore size was a dominant factor in improving steady-state filtration efficiency, as a large-mean-pore-size filter was unable to efficiently separate sub-micrometer-sized droplets even with a high number of layers. Conversely, it was found that re-entrainment of micrometer-sized droplets was prone to occur in small-mean-pore-size oleophobic and large-mean-pore-size oleophilic filters, resulting in the pronounced reduction of steady-state filtration efficiency. Based on quality factors at steady state, a filter with large mean pore size was much superior in separation of micrometer-sized droplets, while a filter with moderate rather than smallest mean pore size, should be applied to separate sub-micrometer-sized droplets.
引用
收藏
页码:71 / 78
页数:8
相关论文
共 23 条
[1]  
Agranovski IE, 1998, AICHE J, V44, P2775, DOI 10.1002/aic.690441218
[2]   Filtration of liquid aerosols on nonwettable fibrous filters [J].
Agranovski, IE ;
Braddock, RD .
AICHE JOURNAL, 1998, 44 (12) :2784-2790
[3]  
Agranovski IE, 2001, CHEM ENG TECHNOL, V24, P287, DOI 10.1002/1521-4125(200103)24:3<287::AID-CEAT287>3.0.CO
[4]  
2-P
[5]  
Brown R. C., 1993, J AEROSOL SCI, DOI DOI 10.1016/0021-8502(95)90072-1
[6]   The effect of a drainage layer on the saturation of coalescing filters in the filtration process [J].
Chang, Cheng ;
Ji, Zhongli ;
Liu, Jialin .
CHEMICAL ENGINEERING SCIENCE, 2017, 160 :354-361
[7]   The effect of a drainage layer on filtration performance of coalescing filters [J].
Chang, Cheng ;
Ji, Zhongli ;
Zeng, Fanyong .
SEPARATION AND PURIFICATION TECHNOLOGY, 2016, 170 :370-376
[8]   Clogging of fibre filters by submicron droplets.: Phenomena and influence of operating conditions [J].
Contal, P ;
Simao, J ;
Thomas, D ;
Frising, T ;
Callé, S ;
Appert-Collin, JC ;
Bémer, D .
JOURNAL OF AEROSOL SCIENCE, 2004, 35 (02) :263-278
[9]  
Davies CharlesNorman., 1973, Air filtration
[10]   Detachment of droplets from cylinders in flow using an experimental analogue [J].
Hotz, C. J. ;
Mead-Hunter, R. ;
Becker, T. ;
King, A. J. C. ;
Wurster, S. ;
Kasper, G. ;
Mullins, B. J. .
JOURNAL OF FLUID MECHANICS, 2015, 771 :327-340