A NEW SYSTEM FOR MEASUREMENT OF THE PULSE TRANSIT TIME, THE PULSE WAVE VELOCITY AND ITS ANALYSIS

被引:7
|
作者
Bereksi-Reguig, Anes. [1 ]
Bereksi-Reguig, F. [1 ]
Ali, A. Nait [2 ]
机构
[1] Univ Tlemcen, Fac Technol, Dept Biomed Engn, Biomed Engn Res Lab, Chetouane, Algeria
[2] Univ Paris Est, LISSI Lab, Creteil, France
关键词
Pulse wave velocity; heart rate variability; electrocardiogram; photoplethysmogram; regression models; HEART-RATE;
D O I
10.1142/S0219519417500105
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Arterial stiffness is a strong determinant of cardiovascular risk. Pulse wave velocity (PWV) is an index of arterial stiffness, and its prognostic value has been repeatedly emphasized. The work presented in this paper is concerned with the design of a new system for measurement of the PWV and analysis. It is in fact related to the description of the hardware setup and the software development in order to measure and analyze the PWV. In the proposed system, the determination of the PWV is carried out through the measurement of the pulse wave transit time (PWTT) using the electrocardiogram (ECG) and the photoplethysmogram (PPG) and the distance separating the site of ejection of the systolic pulse and the site of measuring the PPG signal. The hardware setup therefore consists of an optical device to detect the PPG and electrodes to detect ECG, and different boards to process and digitalize these signals to be acquired in the PC and analyzed. The developed software is concerned with first, the acquisition and processing of both ECG and PPG signals then the determination of the PWV and finally its analysis for different subjects and conditions. The analysis of the PWV is carried out for subjects of different ages in different physiological conditions according to heart activity. The obtained results show that there is a high correlation (r = 0.88), between heart rate variability (HRV) and PWV. They also show that PWV increases with age. The analysis of the PWV variations with age is also carried out through different regression models. The obtained result shows that the cubic regression model best fits these variations.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] Parametric estimation of pulse arrival time: a robust approach to pulse wave velocity
    Sola, Josep
    Vetter, Rolf
    Renevey, Philippe
    Chetelat, Olivier
    Sartori, Claudio
    Rimoldi, Stefano F.
    PHYSIOLOGICAL MEASUREMENT, 2009, 30 (07) : 603 - 615
  • [32] Comparison of arterial stiffness indices measured by pulse wave velocity and pulse wave analysis
    Zhu, Hongyan
    Gao, Yuan
    Cheng, Huiling
    Lu, Yichao
    Cheang, IokFai
    Xu, Dongxu
    Yao, Wenming
    Xu, Tianbao
    Zhou, Fang
    Zhou, Yanli
    Xu, Fang
    Kong, Xiangqing
    Li, Xinli
    Zhang, Haifeng
    BLOOD PRESSURE, 2019, 28 (03) : 206 - 213
  • [33] Reproducibility of pulse wave analysis and pulse wave velocity in patients with type 2 diabetes
    Laugesen, Esben
    Rossen, Niklas B.
    Hoyem, Pernille
    Christiansen, Jens S.
    Knudsen, Soren T.
    Hansen, Klavs W.
    Hansen, Troels K.
    Poulsen, Per L.
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2013, 73 (05): : 428 - 435
  • [34] Increased pulse wave velocity and shortened pulse wave propagation time in young patients with rheumatoid arthritis
    Yildiz, M
    Soy, M
    Kurum, T
    Ozbay, G
    CANADIAN JOURNAL OF CARDIOLOGY, 2004, 20 (11) : 1097 - 1100
  • [35] Improved pressure contour analysis for estimating cardiac stroke volume using pulse wave velocity measurement
    Kamoi, Shun
    Pretty, Christopher
    Balmer, Joel
    Davidson, Shaun
    Pironet, Antoine
    Desaive, Thomas
    Shaw, Geoffrey M.
    Chase, J. Geoffrey
    BIOMEDICAL ENGINEERING ONLINE, 2017, 16
  • [36] A New Noninvasive System for Clinical Pulse Wave Velocity Assessment: The Athos Device
    Buraioli, Irene
    Lena, Davide
    Sanginario, Alessandro
    Leone, Dario
    Mingrone, Giulia
    Milan, Alberto
    Demarchi, Danilo
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2021, 15 (01) : 133 - 142
  • [37] Measurement of pulse wave velocity using magnetic resonance imaging
    Gang, G
    Mark, P
    Cockshott, P
    Foster, J
    Martin, T
    Blyth, K
    Steedman, T
    Elliott, A
    Dargie, H
    Groenning, B
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 3684 - 3687
  • [38] The Method for Pulse Wave Velocity Measurement Based on Chaotic Oscillator
    Deng Chen
    Song WanQing
    2009 INTERNATIONAL CONFERENCE ON ARTIFICIAL INTELLIGENCE AND COMPUTATIONAL INTELLIGENCE, VOL III, PROCEEDINGS, 2009, : 340 - 344
  • [39] Aortic pulse wave velocity measurement in systemic sclerosis patients
    Colaci, M.
    Giuggioli, D.
    Manfredi, A.
    Sebastiani, M.
    Coppi, F.
    Rossi, R.
    Richeldi, L.
    Ferri, C.
    REUMATISMO, 2012, 64 (06) : 360 - 367
  • [40] Pulse Transit Time-Pulse Wave Analysis Fusion Based on Wearable Wrist Ballistocardiogram for Cuff-Less Blood Pressure Trend Tracking
    Yousefian, Peyman
    Shin, Sungtae
    Mousavi, Azin Sadat
    Tivay, Ali
    Kim, Chang-Sei
    Mukkamala, Ramakrishna
    Jang, Dae-Geun
    Ko, Byung Hoon
    Lee, Jongwook
    Kwon, Ui-Kun
    Kim, Youn Ho
    Hahn, Jin-Oh
    IEEE ACCESS, 2020, 8 : 138077 - 138087