On-line monitoring of solvent emission rates using an open path FTIR analyser

被引:3
作者
Räisänen, J [1 ]
Niemelä, R [1 ]
机构
[1] Finnish Inst Occupat Hlth, FIN-01620 Vantaa, Finland
关键词
open path FTIR; on-line monitoring; emission rates; solvent;
D O I
10.1093/annhyg/mef069
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Solvent mixture concentrations in paint and resin manufacture were on-line monitored using a portable open path Fourier transform infrared (OP-FTIR) analyser in order to determine solvent emission rates into workspaces. The mean solvent emission rate was 0.46 kg/h in paint production and 0.35 kg/h in resin manufacture. Expressed as emission factor, i.e. evaporated portion of the total solvent mass used, the corresponding values were 0.01% for paint production and 0.1% for resin manufacture. The OP-FTIR instrument together with advanced spectra analysis software facilitated a rapid identification of solvent mixtures and on-line concentration monitoring with good temporal resolution. The analyser seems to be particularly useful in industrial hygiene applications where spatial average concentrations are needed. The further benefit of the open path instrument is that no sampling lines, pumps or sample cells are needed.
引用
收藏
页码:501 / 506
页数:6
相关论文
共 17 条
  • [1] Farhat S K, 2000, Appl Occup Environ Hyg, V15, P911
  • [2] *FINN MIN SOC AFF, 1988, OCC EXP LIM VAL
  • [3] *FINN STAND ASS, 1978, MEAS ORG VAP WORKPL
  • [4] OPTICAL REMOTE MEASUREMENT OF TOXIC GASES
    GRANT, WB
    KAGANN, RH
    MCCLENNY, WA
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1992, 42 (01): : 18 - 30
  • [5] HERGET WF, 1982, AM LAB, V14, P72
  • [6] *ISO, 1977, MEAS FLUID FLOW CLOS
  • [7] On-line analysis of stack gas composition by a low resolution FT-IR gas analyzer
    Jaakkola, PT
    Vahlman, TA
    Roos, AA
    Saarinen, PE
    Kauppinen, JK
    [J]. WATER AIR AND SOIL POLLUTION, 1998, 101 (1-4) : 79 - 92
  • [8] The evaluation of a low resolution Fourier transform infrared (FTIR) gas analyser for monitoring of solvent emission rates under field conditions
    Räisänen, J
    Niemelä, R
    [J]. JOURNAL OF ENVIRONMENTAL MONITORING, 1999, 1 (06): : 549 - 552
  • [9] SAARINEN P, 1991, APPL SPECTROSC, V45, P935
  • [10] Mapping air contaminants indoors using a prototype computed tomography system
    Samanta, A