Bleeding Rate for Ultrasound-Guided Paracentesis in Thrombocytopenic Patients

被引:23
|
作者
Kurup, A. Nicholas [1 ]
Lekah, Alexander [1 ]
Reardon, Scott T. [4 ]
Schmit, Grant D. [1 ]
McDonald, Jennifer S. [1 ]
Carter, Rickey E. [3 ]
Kamath, Patrick S. [2 ]
Callstrom, Matthew R. [1 ]
Atwell, Thomas D. [1 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
[2] Mayo Clin, Div Gastroenterol & Hepatol, Dept Internal Med, Rochester, MN 55905 USA
[3] Mayo Clin, Dept Biomed Stat & Informat, Rochester, MN 55905 USA
[4] Essentia Hlth, Dept Radiol, Fargo, ND USA
关键词
complications; paracentesis; thrombocytopenia; ultrasound-guided paracentesis; RISK; PATHOPHYSIOLOGY; MANAGEMENT; ASCITES;
D O I
10.7863/ultra.14.10034
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives-The purpose of this study was to determine the rate of major bleeding complications for ultrasound-guided paracentesis performed in thrombocytopenic patients. Methods-We retrospectively reviewed the electronic medical records of patients with platelet counts of less than 50,000/mu L who had ultrasound-guided paracenteses performed in the Department of Radiology without correcting preprocedural platelet transfusions between 2005 and 2011. Medical records were evaluated for evidence of major bleeding complications (grade 3 or higher as defined by the National Institutes of Health's Common Terminology Criteria for Adverse Events, version 4.03) and their clinical sequelae. Platelet count and bleeding complications were evaluated for an association, and a sensitivity analysis was performed to determine whether analysis of a control group of patients without thrombocytopenia would yield added confidence in this assessment. Results-Among 304 procedures in 205 thrombocytopenic patients (69% male; mean age +/- SD, 56.6 +/- 11.9 years), the mean platelet count was 38,400 +/- 9300/mu L (range, 9000-49,000/mu L). Three major bleeding complications requiring red blood cell transfusion were observed in patients with platelet counts of 41,000 to 46,000/mu L, for a complication rate of 0.99% (95% confidence interval, 0.3%-2.9%). No patient required an additional procedure or died because of the bleeding complication. There was no association of platelet count with bleeding complications. The sensitivity analysis showed that further evaluation of patients with normal platelet counts would not add to the conclusion. Conclusions-The risk of major bleeding after ultrasound-guided paracentesis in thrombocytopenic patients is very low. In most patients, routine assessment of the preprocedural serum platelet concentration is not necessary, and correction of such an abnormal laboratory value is not indicated.
引用
收藏
页码:1833 / 1838
页数:6
相关论文
共 50 条
  • [41] Ultrasound-guided bursal injections
    McGill, Kevin C.
    Patel, Rina
    Chen, David
    Okwelogu, Nikki
    SKELETAL RADIOLOGY, 2023, 52 (05) : 967 - 978
  • [42] Ultrasound-guided percutaneous tracheostomy
    Plata, Piotr
    Gaszynski, Tomasz
    ANAESTHESIOLOGY INTENSIVE THERAPY, 2019, 51 (02) : 126 - 132
  • [43] Ultrasound-Guided Hip Injections
    Lynch, T. Sean
    Oshlag, Benjamin L.
    Bottiglieri, Thomas S.
    Desai, Natasha N.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2019, 27 (10) : E451 - E461
  • [44] Ultrasound-guided percutaneous laser ablation is safe and effective in the treatment of small renal tumors in patients at increased bleeding risk
    Sartori, Sergio
    Mauri, Giovanni
    Tombesi, Paola
    Di Vece, Francesca
    Bianchi, Lara
    Pacella, Claudio Maurizio
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2018, 35 (01) : 19 - 25
  • [45] Ultrasound-guided renal biopsy
    Rivera Gorrin, M.
    NEFROLOGIA, 2010, 30 (05): : 490 - 492
  • [46] Ultrasound-guided percutaneous tracheostomy in critically ill obese patients
    Guinot, Pierre-Gregoire
    Zogheib, Elie
    Petiot, Sandra
    Marienne, Jean-Pierre
    Guerin, Anne-Marie
    Monet, Pauline
    Zaatar, Rody
    Dupont, Herve
    CRITICAL CARE, 2012, 16 (02):
  • [47] Safety of ultrasound-guided percutaneous suprapubic catheter insertion in spinal cord injury patients
    Tiburtius, Christian
    Fiebag, Kai
    Kowald, Birgitt
    Balzer, Oliver
    Hirschfeld-Araujo, Sven
    Thietje, Roland
    Boethig, Ralf
    SPINAL CORD SERIES AND CASES, 2024, 10 (01):
  • [48] Risk of Bleeding with Endoscopic Ultrasound-Guided Tissue Acquisition in Patients on Antithrombotic Therapy: A Systematic Review and Meta-Analysis
    Giri, Suprabhat
    Afzalpurkar, Shivaraj
    Anirvan, Prajna
    Angadi, Sumaswi
    Kasturi, Sunil
    Varghese, Jijo
    Sundaram, Sridhar
    DIGESTIVE DISEASES AND SCIENCES, 2023, 68 (05) : 1950 - 1958
  • [49] Safety and effectiveness of ultrasound-guided percutaneous transhepatic biliary drainage: a multicenter experience
    Giurazza, Francesco
    Corvino, Fabio
    Contegiacomo, Andrea
    Marra, Paolo
    Lucarelli, Nicola Maria
    Calandri, Marco
    Silvestre, Mattia
    Corvino, Antonio
    Lucatelli, Pierleone
    De Cobelli, Francesco
    Niola, Raffaella
    Cariati, Maurizio
    JOURNAL OF ULTRASOUND, 2019, 22 (04) : 437 - 445
  • [50] The impact of bleeding times on major complication rates after percutaneous real-time ultrasound-guided renal biopsies
    Stiles, KP
    Hill, C
    LeBrun, C
    Reinmuth, B
    Yuan, CM
    Abbott, KC