Bleeding Rate for Ultrasound-Guided Paracentesis in Thrombocytopenic Patients

被引:23
|
作者
Kurup, A. Nicholas [1 ]
Lekah, Alexander [1 ]
Reardon, Scott T. [4 ]
Schmit, Grant D. [1 ]
McDonald, Jennifer S. [1 ]
Carter, Rickey E. [3 ]
Kamath, Patrick S. [2 ]
Callstrom, Matthew R. [1 ]
Atwell, Thomas D. [1 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
[2] Mayo Clin, Div Gastroenterol & Hepatol, Dept Internal Med, Rochester, MN 55905 USA
[3] Mayo Clin, Dept Biomed Stat & Informat, Rochester, MN 55905 USA
[4] Essentia Hlth, Dept Radiol, Fargo, ND USA
关键词
complications; paracentesis; thrombocytopenia; ultrasound-guided paracentesis; RISK; PATHOPHYSIOLOGY; MANAGEMENT; ASCITES;
D O I
10.7863/ultra.14.10034
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives-The purpose of this study was to determine the rate of major bleeding complications for ultrasound-guided paracentesis performed in thrombocytopenic patients. Methods-We retrospectively reviewed the electronic medical records of patients with platelet counts of less than 50,000/mu L who had ultrasound-guided paracenteses performed in the Department of Radiology without correcting preprocedural platelet transfusions between 2005 and 2011. Medical records were evaluated for evidence of major bleeding complications (grade 3 or higher as defined by the National Institutes of Health's Common Terminology Criteria for Adverse Events, version 4.03) and their clinical sequelae. Platelet count and bleeding complications were evaluated for an association, and a sensitivity analysis was performed to determine whether analysis of a control group of patients without thrombocytopenia would yield added confidence in this assessment. Results-Among 304 procedures in 205 thrombocytopenic patients (69% male; mean age +/- SD, 56.6 +/- 11.9 years), the mean platelet count was 38,400 +/- 9300/mu L (range, 9000-49,000/mu L). Three major bleeding complications requiring red blood cell transfusion were observed in patients with platelet counts of 41,000 to 46,000/mu L, for a complication rate of 0.99% (95% confidence interval, 0.3%-2.9%). No patient required an additional procedure or died because of the bleeding complication. There was no association of platelet count with bleeding complications. The sensitivity analysis showed that further evaluation of patients with normal platelet counts would not add to the conclusion. Conclusions-The risk of major bleeding after ultrasound-guided paracentesis in thrombocytopenic patients is very low. In most patients, routine assessment of the preprocedural serum platelet concentration is not necessary, and correction of such an abnormal laboratory value is not indicated.
引用
收藏
页码:1833 / 1838
页数:6
相关论文
共 50 条
  • [31] Endoscopic ultrasound-guided ethanol ablation versus surgical resection of insulinomas
    Juergensen, Christian
    Eckart, Marius
    Haberbosch, Linus
    Tacke, Frank
    Sandforth, Arvid
    Birkenfeld, Andreas L.
    Overkamp, Dietrich
    Daniels, Martin
    Mogl, Martina
    Goretzki, Peter
    Strasburger, Christian
    Mai, Knut
    Spranger, Joachim
    von Schwartzenberg, Reiner Jumpert
    ULTRASCHALL IN DER MEDIZIN, 2024, : 519 - 527
  • [32] Efficacy and safety of ultrasound guided percutaneous glue embolization in iatrogenic haemorrhagic complications of paracentesis and thoracocentesis in cirrhotic patients
    Mukund, Amar
    Kumar, Vinay
    Condati, Naveen Kumar
    Bhadoria, Ajeet Singh
    Sarin, Shiv Kumar
    BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1081)
  • [33] Pocket ultrasound device as a complement to physical examination for ascites evaluation and guided paracentesis
    Daniel Keil-Ríos
    Hiram Terrazas-Solís
    Alejandro González-Garay
    Juan Francisco Sánchez-Ávila
    Ignacio García-Juárez
    Internal and Emergency Medicine, 2016, 11 : 461 - 466
  • [34] Pocket ultrasound device as a complement to physical examination for ascites evaluation and guided paracentesis
    Keil-Rios, Daniel
    Terrazas-Solis, Hiram
    Gonzalez-Garay, Alejandro
    Francisco Sanchez-Avila, Juan
    Garcia-Juarez, Ignacio
    INTERNAL AND EMERGENCY MEDICINE, 2016, 11 (03) : 461 - 466
  • [35] Color Doppler ultrasound-guided transducer compression of post biopsy bleeding of kidney transplants
    Brabrand, Knut
    Midtvedt, Karsten
    Gunther, Anne
    Marthinsen, Pal Bache
    Berstad, Audun Elnaes
    JOURNAL OF CLINICAL ULTRASOUND, 2013, 41 (01) : 26 - 31
  • [36] Transrectal ultrasound-guided biopsy of the prostate: relation between ASA use and bleeding complications
    Herget, EJ
    Saliken, JC
    Donnelly, BJ
    Gray, RR
    Wiseman, D
    Brunet, G
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 1999, 50 (03): : 173 - 176
  • [37] Transcatheter arterial embolization for iatrogenic bleeding after endoscopic ultrasound-guided pancreaticobiliary drainage
    Lee, N. J.
    Shin, J. H.
    Lee, S. S.
    Park, D. H.
    Lee, S. K.
    Yoon, H. -K.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2018, 99 (11) : 717 - 724
  • [38] ULTRASOUND-GUIDED TALONAVICULAR ARTHROCENTESIS
    Thom, Christopher
    Pozner, Jonathan
    Kongkatong, Matthew
    Moak, James
    JOURNAL OF EMERGENCY MEDICINE, 2020, 60 (05) : 633 - 636
  • [39] Basic Ultrasound-guided Procedures
    Barr, Laurel
    Hatch, Nicholas
    Roque, Pedro J.
    Wu, Teresa S.
    CRITICAL CARE CLINICS, 2014, 30 (02) : 275 - +
  • [40] Ultrasound-guided renal biopsy
    Hunter, Robert W.
    Ramaswamy, Rajesh
    Patel, Dilip
    Dhaun, Neeraj
    BRITISH JOURNAL OF HOSPITAL MEDICINE, 2017, 78 (04) : C56 - C59