Optimized Determination of Caffeine, Equol, and Artemisinin by High-Performance Thin-Layer Chromatography-Direct Analysis in Real Time-Time of Flight-Mass Spectrometry

被引:6
作者
Eichner, Fabian [1 ]
Spangenberg, Bernd [2 ]
机构
[1] Univ Appl Sci Bremerhaven, Dept 1, Karlstadt 8, D-27568 Bremerhaven, Germany
[2] Univ Appl Sci Offenburg, Dept Proc Engn, Badstr 24, D-77652 Offenburg, Germany
关键词
High-performance thin-layer chromatography; Thin-layer chromatography; Direct analysis in real time-mass spectrometry; Caffeine; Equol; Artemisinin; SCANNING DIRECT ANALYSIS; PLANAR CHROMATOGRAPHY; IDENTIFICATION; TLC; TOOL; OIL;
D O I
10.1556/1006.2019.32.3.4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We present a planar chromatographic separation method for the compounds caffeine, artemisinin, and equol, separated on high-performance thin-layer chromatography (HPTLC) silica gel plates. As solvents for separation, methyl t-butyl ether and cyclohexane (1:1, V/V) have been used for equol, cyclohexane and ethyl acetate (7:3, V/V) for artemisinin, and ethyl acetate and acetone (7:3, V/V) for caffeine. After separation, the plate was scanned with a very specific time of flight-direct analysis in real time-mass spectrometry (TOF-DART-MS) system using the (M + 1)(+) signals of equol, artemisinin, and caffeine. The (M + 1) peak of artemisinin at 283.13 m/z is clearly detectable, which is the proof that DART-MS is applicable for the quantitative determination of rather instable molecules. The planar set-up of DART source, HPTLC plate and detector inlet in a line showed higher sensitivities compared to desorption at an angle. The optimal detector voltage increases with the molar mass of the analyte, thus an individual determination of optimal detector voltage setting for the different analyte is recommended to achieve the best possible measurement conditions. In conclusion, DART-MS detection in combination with an HPTLC separation allows very specific quantification of all three compounds.
引用
收藏
页码:197 / 203
页数:7
相关论文
共 31 条
[1]   Dielectric Barrier Discharge Ionization in Characterization of Organic Compounds Separated on Thin-Layer Chromatography Plates [J].
Ceglowski, Michal ;
Smoluch, Marek ;
Babij, Michal ;
Gotszalk, Teodor ;
Silberring, Jerzy ;
Schroeder, Grzegorz .
PLOS ONE, 2014, 9 (08)
[2]   Profiling and classification of French propolis by combined multivariate data analysis of planar chromatograms and scanning direct analysis in real time mass spectra [J].
Chasset, Thibaut ;
Haebe, Tim T. ;
Ristivojevic, Petar ;
Morlock, Gertrud E. .
JOURNAL OF CHROMATOGRAPHY A, 2016, 1465 :197-204
[3]   Some new features of Direct Analysis in Real Time mass spectrometry utilizing the desorption at an angle option [J].
Chernetsova, Elena S. ;
Revelsky, Alexander I. ;
Morlock, Gertrud E. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (16) :2275-2282
[4]   Versatile new ion source for the analysis of materials in open air under ambient conditions [J].
Cody, RB ;
Laramée, JA ;
Durst, HD .
ANALYTICAL CHEMISTRY, 2005, 77 (08) :2297-2302
[5]  
Crawford E., 2014, INT S HIGH PERF THIN
[6]   The use of HPTLC and Direct Analysis in Real Time-Of-Flight Mass Spectrometry (DART-TOF-MS) for rapid analysis of degradation by oxidation and sonication of an azo dye [J].
Djelal, Hayet ;
Cornee, Carole ;
Tartivel, Ronan ;
Lavastre, Olivier ;
Abdeltif, Amrane .
ARABIAN JOURNAL OF CHEMISTRY, 2017, 10 :S1619-S1628
[7]  
Dong Y., 2018, Direct Analysis in Real Time Mass Spectrometry: Principles and Practices of DART-MS
[8]  
Dytkiewitz E, 2008, J AOAC INT, V91, P1237
[9]  
Funk W., 1985, Statistische Methoden in der Wasseranalytik: Begriffe, Strategien, Anwendungen
[10]   Direct bioautography hyphenated to direct analysis in real time mass spectrometry: Chromatographic separation, bioassay and mass spectra, all in the same sample run [J].
Haebe, Tim T. ;
Jamshidi-Aidji, Maryam ;
Macho, Jennifer ;
Morlock, Gertrud E. .
JOURNAL OF CHROMATOGRAPHY A, 2018, 1568 :188-196