Effect of remote monitoring on clinical outcomes in European heart failure patients with an implantable cardioverter-defibrillator: secondary results of the REMOTE-CIED randomized trial

被引:21
|
作者
Chiu, Cheyenne S. L. [1 ]
Timmermans, Ivy [1 ,2 ]
Versteeg, Henneke [1 ]
Zitron, Edgar [3 ]
Mabo, Philippe [4 ]
Pedersen, Susanne S. [5 ,6 ]
Meine, Mathias [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Cardiol, Heidelberglaan 100, NL-3584 CX Utrecht, Netherlands
[2] Tilburg Univ, CoRPS Ctr Res Psychol Somat Dis, Dept Med & Clin, Tilburg, Netherlands
[3] Univ Klinikum Heidelberg, Dept Cardiol, Heidelberg, Germany
[4] CHU, Dept Cardiol, Rennes, France
[5] Univ Southern Denmark, Dept Psychol, Odense, Denmark
[6] Odense Univ Hosp, Dept Cardiol, Odense, Denmark
来源
EUROPACE | 2022年 / 24卷 / 02期
关键词
REMOTE-CIED; Implantable cardioverter-defibrillator; Heart failure; Remote monitoring; Clinical outcomes; ELECTRONIC DEVICES; EXPERT CONSENSUS; THERAPY; METAANALYSIS; GUIDELINES;
D O I
10.1093/europace/euab221
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Remote patient monitoring (RPM) systems offer a promising alternative to conventional In-Clinic check-ups, hereby reducing unnecessary clinic visits. Especially with the rise of the COVID-19 pandemic, this reduction is of paramount importance. Regarding the association between RPM and clinical outcomes, findings of previous studies have been inconsistent. The aim of this study is to elucidate the effect of partly substituting In-Clinic visits by RPM on clinical outcomes in implantable cardioverter-defibrillator (ICD) patients. Methods and results The study included 595 heart failure patients (LVEF <= 35%; NYHA Class II/III) implanted with an ICD compatible with the Boston Scientific LATITUDE (TM) system. Participants were randomized to RPM plus an annual In-Clinic visit or 3-6 months In-Clinic check-ups alone. The investigated endpoints after 2 years of follow-up included a composite of all-cause mortality and cardiac hospitalization, mortality and cardiac hospitalization as independent endpoints and ICD therapy. The incidence of mortality and hospitalization did not differ significantly as independent, nor as composite endpoint between the RPM and In-Clinic group (all Ps <0.05). The results were similar regarding ICD therapy, except for appropriate ICD therapy (odds ratio 0.50; 95% confidence interval 0.26-0.98; P = 0.04). Exploratory subgroup analyses indicated that the effect of RPM differs between patients with specific characteristics, i.e. >= 60 years and permanent atrial fibrillation (all Ps < 0.05). Conclusion RPM is non-inferior to conventional In-Clinic visits regarding clinical outcomes. Routine In-Clinic follow-up may partly be substituted by RPM without jeopardizing safety and efficiency, and thus reducing unnecessary In-Clinic visits. ClinicalTrials.gov identifier NCT01691586.
引用
收藏
页码:256 / 267
页数:12
相关论文
共 50 条
  • [31] Rapid-Rate Nonsustained Ventricular Tachycardia Found on Implantable Cardioverter-Defibrillator Interrogation Relationship to Outcomes in the SCD-HeFT (Sudden Cardiac Death in Heart Failure Trial)
    Chen, Jay
    Johnson, George
    Hellkamp, Anne S.
    Anderson, Jill
    Mark, Daniel B.
    Lee, Kerry L.
    Bardy, Gust H.
    Poole, Jeanne E.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (21) : 2161 - 2168
  • [32] Long-term monitoring of respiratory rate in patients with heart failure: the Multiparametric Heart Failure Evaluation in Implantable Cardioverter-Defibrillator Patients (MULTITUDE-HF) study
    Forleo, Giovanni B.
    Santini, Luca
    Campoli, Massimiliano
    Malavasi, Mario
    Scaccia, Alberto
    Menichelli, Maurizio
    Riva, Umberto
    Lamberti, Filippo
    Carreras, Giovanni
    Orazi, Serafino
    Ribatti, Valentina
    Di Biase, Luigi
    Lovecchio, Mariolina
    Natale, Andrea
    Valsecchi, Sergio
    Romeo, Francesco
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2015, 43 (02) : 135 - 144
  • [33] Defibrillation testing and clinical outcomes after implantable cardioverter-defibrillator implantation in patients in atrial fibrillation at the time of implant: An analysis from the SIMPLE trial
    Bogdan, Stefan
    Glikson, Michael
    Connolly, Stuart J.
    Wang, Jia
    Hohnloser, Stefan H.
    Appl, Ursula
    Neuzener, Jorg
    Mabo, Philippe
    Vinolas, Xavier
    Gadler, Frederick
    van Erven, Lieselot
    Kautzner, Josef
    Meeks, Brandi
    Pogue, Janice
    Healey, Jeff S.
    HEART RHYTHM, 2019, 16 (01) : 83 - 90
  • [34] Effect of Sleep-Disordered Breathing on Appropriate Implantable Cardioverter-Defibrillator Therapy in Patients With Heart Failure A Systematic Review and Meta-Analysis
    Kwon, Younghoon
    Koene, Ryan J.
    Kwon, Osung
    Kealhofer, Jessica V.
    Adabag, Selcuk
    Duval, Sue
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2017, 10 (02)
  • [35] Impact of Implantable Cardioverter-Defibrillator, Amiodarone, and Placebo on the Mode of Death in Stable Patients With Heart Failure Analysis From the Sudden Cardiac Death in Heart Failure Trial
    Packer, Douglas L.
    Prutkin, Jordan M.
    Hellkamp, Anne S.
    Mitchell, L. Brent
    Bernstein, Robert C.
    Wood, Freda
    Boehmer, John P.
    Carlson, Mark D.
    Frantz, Robert P.
    McNulty, Steve E.
    Rogers, Joseph G.
    Anderson, Jill
    Johnson, George W.
    Walsh, Mary Norine
    Poole, Jeanne E.
    Mark, Daniel B.
    Lee, Kerry L.
    Bardy, Gust H.
    CIRCULATION, 2009, 120 (22) : 2170 - 2176
  • [36] Long-term monitoring of respiratory rate in patients with heart failure: the Multiparametric Heart Failure Evaluation in Implantable Cardioverter-Defibrillator Patients (MULTITUDE-HF) study
    Giovanni B. Forleo
    Luca Santini
    Massimiliano Campoli
    Mario Malavasi
    Alberto Scaccia
    Maurizio Menichelli
    Umberto Riva
    Filippo Lamberti
    Giovanni Carreras
    Serafino Orazi
    Valentina Ribatti
    Luigi Di Biase
    Mariolina Lovecchio
    Andrea Natale
    Sergio Valsecchi
    Francesco Romeo
    Journal of Interventional Cardiac Electrophysiology, 2015, 43 : 135 - 144
  • [37] Multicenter randomized study of anticoagulation guided by remote rhythm monitoring in patients with implantable cardioverter-defibrillator and CRT-D devices: Rationale, design, and clinical characteristics of the initially enrolled cohort: The IMPACT study
    Ip, John
    Waldo, Albert L.
    Lip, Gregory Y. H.
    Rothwell, Peter M.
    Martin, David T.
    Bersohn, Malcolm M.
    Choucair, Wassim K.
    Akar, Joseph G.
    Wathen, Mark S.
    Rohani, Pooyan
    Halperin, Jonathan L.
    AMERICAN HEART JOURNAL, 2009, 158 (03) : 364 - U10
  • [38] Remote Monitoring and Behavioral Economics in Managing Heart Failure in Patients Discharged From the Hospital A Randomized Clinical Trial
    Asch, David A.
    Troxel, Andrea B.
    Goldberg, Lee R.
    Tanna, Monique S.
    Mehta, Shivan J.
    Norton, Laurie A.
    Zhu, Jingsan
    Iannotte, Lauren G.
    Klaiman, Tamar
    Lin, Yuqing
    Russell, Louise B.
    Volpp, Kevin G.
    JAMA INTERNAL MEDICINE, 2022, 182 (06) : 643 - 649
  • [39] Remote monitoring of implantable cardiac devices in heart failure patients: a systematic review and meta-analysis of randomized controlled trials
    Sultan Alotaibi
    Jaime Hernandez-Montfort
    Omar E. Ali
    Karim El-Chilali
    Bernardo A. Perez
    Heart Failure Reviews, 2020, 25 : 469 - 479
  • [40] Remote monitoring of implantable cardiac devices in heart failure patients: a systematic review and meta-analysis of randomized controlled trials
    Alotaibi, Sultan
    Hernandez-Montfort, Jaime
    Ali, Omar E.
    El-Chilali, Karim
    Perez, Bernardo A.
    HEART FAILURE REVIEWS, 2020, 25 (03) : 469 - 479