MR-compatible polyetheretherketone-based guide wire assisting MR-guided stenting of iliac and supraaortic arteries in swine: Feasibility study

被引:15
作者
Kos, Sebastian [1 ]
Huegli, Rolf [2 ]
Hofmann, Eugen [3 ]
Quick, Harald H. [4 ]
Kuehl, Hilmar [4 ]
Aker, Stephanie [5 ]
Kaiser, Gernot M. [6 ]
Borm, Paul J. A. [7 ]
Jacob, Augustinus L.
Bilecen, Deniz
机构
[1] Univ Basel Hosp, Inst Radiol, Div Intervent Radiol, CH-4031 Basel, Switzerland
[2] Kantonsspital Bruderholz, Inst Radiol, Bruderholz, Switzerland
[3] Biotronik, Vasc Intervent, Bulach, Switzerland
[4] Univ Duisburg Essen, Dept Diagnost & Intervent Radiol & Neuroradiol, Essen, Germany
[5] Univ Duisburg Essen, Inst Pathophysiol, Essen, Germany
[6] Univ Duisburg Essen, Dept Gen Visceral & Transplantat Surg, Essen, Germany
[7] MagnaMed GmbH, Aachen, Germany
关键词
Guide wire; stenting; supraaortic; iliac; PEEK; MR-compatible; MAGNETIC-RESONANCE ANGIOGRAPHY; INTERVENTIONAL MRI; ANIMAL-MODEL; ANGIOPLASTY; PLACEMENT; GUIDANCE; VISUALIZATION; CATHETERS; SAFETY; PIGS;
D O I
10.1080/13645700902921971
中图分类号
R61 [外科手术学];
学科分类号
摘要
The purpose of this study was to demonstrate first magnetic resonance (MR)-guided stenting of iliac and supraaortic arteries using a polyetheretherketone-based (PEEK) MR-compatible guide wire. In vitro and animal experiments were performed in a short magnet wide-bore scanner (1.5 Tesla, Espree (R), Siemens Healthcare, Erlangen, Germany). For all experiments, a 0.035 '' MR-compatible guide wire prototoype was used. This wire had a compound core of PEEK with reinforcing fibres, a soft and atraumatic tip and a hydrophilic coating. For its passive visualization, paramagnetic markings were attached. All experiments were performed through a vascular introducer sheath under MR-guidance. In vitro repetitive selective over the wire catheterizations of either the right carotid artery and the left subclavian artery were performed. In vivo, selective catheterization and over-the-wire stenting of the brachiocephalic trunc and the left subclavian artery were performed. The common iliac arteries were catheterized retrogradely (left) and cross-over (right). Angioplasty and stenting were performed over-the-wire. All procedures were successful. Visibility of the PEEK-based guide-wire was rated good in vitro and acceptable in vivo. Guide wire pushability and endovascular device support were good. The PEEK-based MR-compatible guide wire is well visible and usable under MR-guidance. It supports over-the-wire treatment of iliac arteries and supraaortic arteries.
引用
收藏
页码:181 / 188
页数:8
相关论文
共 32 条
[1]   MR-guided intravascular interventions: Techniques and applications [J].
Bock, Michael ;
Wacker, Frank K. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (02) :326-338
[2]   MR angiography with blood pool contrast agents MR angiography with blood pool contrast agents [J].
Bremerich, Jens ;
Bilecen, Deniz ;
Reimer, Peter .
EUROPEAN RADIOLOGY, 2007, 17 (12) :3017-3024
[3]   Real-time MR guidance for inferior vena cava filter placement in an animal model [J].
Bücker, A ;
Neuerburg, JM ;
Adam, GB ;
Glowinski, A ;
Schaeffter, T ;
Rasche, V ;
van Vaals, JJ ;
Günther, RW .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 12 (06) :753-756
[4]   Simultaneous real-time visualization of the catheter tip and vascular anatomy for MR-guided PTA of iliac arteries in an animal model [J].
Buecker, A ;
Adam, GB ;
Neuerburg, JM ;
Kinzel, S ;
Glowinski, A ;
Schaeffter, T ;
Rasche, V ;
van Vaals, JJ ;
Guenther, RW .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 16 (02) :201-208
[5]   Feasibility of real-time magnetic resonance-guided stent-graft placement in a swine model of descending aortic dissection [J].
Eggebrecht, H ;
Kühl, H ;
Kaiser, GM ;
Aker, S ;
Zenge, MO ;
Stock, F ;
Breuckmann, F ;
Grabellus, F ;
Ladd, ME ;
Mehta, RH ;
Erbel, R ;
Quick, HH .
EUROPEAN HEART JOURNAL, 2006, 27 (05) :613-620
[6]   Feasibility of stent placement in carotid arteries with real-time MR imaging guidance in pigs [J].
Feng, L ;
Dumoulin, CL ;
Dashnaw, S ;
Darrow, RD ;
DeLaPaz, RL ;
Bishop, PL ;
Pile-Spellman, J .
RADIOLOGY, 2005, 234 (02) :558-562
[7]   Improvement of the MR imaging behavior of vascular implants [J].
Immel, Erwin ;
Melzer, Andreas .
MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2006, 15 (02) :85-92
[8]  
Kaiser GM, 2007, J AM ASSOC LAB ANIM, V46, P30
[9]  
KOS S, 2008, CARDIOVASC INTERVENT
[10]   MR-guided endovascular interventions: a comprehensive review on techniques and applications [J].
Kos, Sebastian ;
Huegli, Rolf ;
Bongartz, Georg M. ;
Jacob, Augustinus L. ;
Bilecen, Deniz .
EUROPEAN RADIOLOGY, 2008, 18 (04) :645-657