Observational study of accuracy in compounding i.v. admixtures at five hospitals

被引:86
作者
Flynn, EA [1 ]
Pearson, RE [1 ]
Barker, KN [1 ]
机构
[1] AUBURN UNIV, DEPT PHARM CARE SYST, AUBURN, AL 36849 USA
关键词
D O I
10.1093/ajhp/54.8.904
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Rates of errors in i.v. admixture compounding at five U.S. hospital pharmacies were studied. Pharmacy staff members at five hospitals representing each U.S. geographic region were observed as they compounded sterile products in order to record the medication, dose, base solution, and other details. Intravenous admixtures, antineoplastic preparations, parenteral nutrient solutions, and ready-to-use products were included. Observations took place for five days at each pharmacy. The observers' notes were checked against the labels used to prepare the doses; any deviation was considered an error. The clinical importance of each error was assessed for its potential to affect a patient adversely. The mean error rate far the five hospitals combined was 9% (145 errors for 1679 doses), excluding ready-to-use products. Mean error rates for individual pharmacies ranged from 6% to 10%. Wrong-dose errors were the most common type of error. Parenteral nutrient solutions had the highest error rates-37% for manual preparation and 22% for preparation that was partly automated. Of every 100 errors, 2 were judged to be potentially clinically important. In five U.S. hospital pharmacies, the observed error rate for compounding i.v. admixtures was 9%.
引用
收藏
页码:904 / 912
页数:9
相关论文
共 24 条
  • [1] FUNDAMENTALS OF MEDICATION ERROR RESEARCH
    ALLAN, EL
    BARKER, KN
    [J]. AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1990, 47 (03): : 555 - 571
  • [2] COMMERCIAL IV FLUID OVERFILL EFFECTS ON CONTINUOUS-INFUSION DRUG ADMINISTRATION AND ASSESSMENT
    ANDERSON, DA
    MARQUARDT, ED
    [J]. DRUG INTELLIGENCE & CLINICAL PHARMACY, 1983, 17 (11): : 847 - 848
  • [3] [Anonymous], 1993, AM J HOSP PHARM, V50, P2386
  • [4] ARMITSTEAD JA, 1983, CLIN PHARMACY, V2, P153
  • [5] BARKER KN, 1967, STUDY MED ERRORS HOS
  • [6] ILLUMINATION AND ERRORS IN DISPENSING
    BUCHANAN, TL
    BARKER, KN
    GIBSON, JT
    JIANG, BC
    PEARSON, RE
    [J]. AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1991, 48 (10): : 2137 - 2145
  • [7] ROBOTIC SYSTEM FOR IV ANTINEOPLASTIC DRUG PREPARATION - DESCRIPTION AND PRELIMINARY EVALUATION UNDER SIMULATED CONDITIONS
    COTE, DD
    TORCHIA, MG
    [J]. AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1989, 46 (11): : 2286 - 2293
  • [8] ACCURACY AND VARIABILITY OF INTRAVENOUS THEOPHYLLINE PREPARATIONS
    DASTA, JF
    BONFIGLIO, MF
    RAGUE, NG
    SHIELDS, BJ
    [J]. THERAPEUTIC DRUG MONITORING, 1990, 12 (06) : 554 - 557
  • [9] DAVIS NM, 1996, HOSP PHARM, V31, P14
  • [10] AUTOMATED COMPOUNDER FOR ADDING INGREDIENTS TO PARENTERAL NUTRIENT BASE SOLUTIONS
    DICKSON, LB
    SOMANI, SM
    HERRMANN, G
    ABRAMOWITZ, PW
    [J]. AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1993, 50 (04): : 678 - 682