The Boston Keratoprosthesis: Comparing Corneal Epithelial Cell Compatibility with Titanium and PMMA

被引:33
作者
Ament, Jared D. [1 ,2 ]
Spurr-Michaud, Sandra J. [1 ]
Dohlman, Claes H. [1 ,2 ]
Gipson, Ilene K. [1 ]
机构
[1] Harvard Univ, Sch Med, Schepens Eye Res Inst, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Massachusetts Eye & Ear Infirm, Boston, MA 02114 USA
关键词
Boston Keratoprosthesis; biomaterials; titanium; corneal cell compatibility; INTRAOCULAR LENSES; RESIDUAL MONOMER; BIOMATERIALS; CYTOTOXICITY; PARTICLES; RESINS;
D O I
10.1097/ICO.0b013e31819670ac
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine in vitro whether titanium is superior corneal cell compatibility to standard polymethyl-methacryl ate (PMMA) for the Boston Keratoprosthesis (KPro). Methods: Human corneal-limbal epithelial (HCLE) cells were Cultured 24, 48, 72 96, 120, 144. or 168 hours in culture plates alone (controls) or with PMMA or titanium discs. Experiments were performed in triplicate and repeated (final n = 6). To determine if a Soluble, toxic factor is emitted from materials, concurrent experiments at 48 and 144 hours were performed with discs placed in Transwell Supports, with HCLE cells plated beneath. As an additional test for soluble factors, cells were incubated 24 hours with disc-conditioned media, and number of viable cells per well was quantified at each timepoint by proliferation assay. To determine if delayed cell proliferation was attributable to cell death, HCLE cell death was measured under all conditions and quantified at each timepoint by cytotoxicity assay. The effects of material on HCLE cell proliferation over time was determined by repeated measures ANOVA. P < 0.05 was statistically significant. Results: HCLE cell proliferation was greater in wells with titanium discs compared to PMMA. Differences between the test discs and control non-disc cocultures were statistically significant over time for both cell proliferation (P = 0.001) and death (P = 0.0025). No significant difference Was found using Transwells (P = 0.9836) or disc-conditioned media (P = 0.36). Conclusion: This in vitro HCLE cell model demonstrates significantly increased cell proliferation and decreased cell death with cell/titanium contact compared to cell/PMNA contact. Moreover, differences are unlikely attributable to a soluble factor. Prospective in vivo analysis of the two KPro biomaterials is indicated.
引用
收藏
页码:808 / 811
页数:4
相关论文
共 25 条
  • [1] The profile of repeated corneal transplantation
    Bersudsky, V
    Blum-Hareuveni, T
    Rehany, U
    Rumelt, S
    [J]. OPHTHALMOLOGY, 2001, 108 (03) : 461 - 469
  • [2] INVITRO CYTOTOXICITY OF MELANIZED POLY(2-HYDROXYETHYL METHACRYLATE) HYDROGELS, A NOVEL CLASS OF OCULAR BIOMATERIALS
    CHIRILA, TV
    THOMPSON, DE
    CONSTABLE, IJ
    [J]. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 1992, 3 (06) : 481 - 498
  • [3] CYTOTOXIC EFFECTS OF RESIDUAL CHEMICALS FROM POLYMERIC BIOMATERIALS FOR ARTIFICIAL SOFT INTRAOCULAR LENSES
    CHIRILA, TV
    WALKER, LN
    CONSTABLE, IJ
    THOMPSON, DE
    BARRETT, GD
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1991, 17 (02) : 154 - 162
  • [4] Introduction to the use of the Boston keratoprosthesis
    Dohlman, Claes H.
    Harissi-Dagher, Mona
    Khan, Bilal F.
    Sippel, Kimberly
    Aquavella, James V.
    Graney, John M.
    [J]. EXPERT REVIEW OF OPHTHALMOLOGY, 2006, 1 (01) : 41 - 48
  • [5] Histopathology of explanted collar button keratoprostheses: A clinicopathologic correlation
    Dudenhoefer, EJ
    Nouri, M
    Gipson, IK
    Baratz, KH
    Tisdale, AS
    Dryja, TP
    Abad, JC
    Dohlman, CH
    [J]. CORNEA, 2003, 22 (05) : 424 - 428
  • [6] Frick Chris, 2006, J Long Term Eff Med Implants, V16, P423
  • [7] Mucin gene expression in immortalized human corneal-limbal and conjunctival epithelial cell lines
    Gipson, IK
    Spurr-Michaud, S
    Argüeso, P
    Tisdale, A
    Ng, TF
    Russo, CL
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (06) : 2496 - 2506
  • [8] Importance of nutrition to corneal grafts when used as a carrier of the Boston keratoprosthesis
    Harissi-Dagher, Mona
    Khan, Bilal F.
    Schaumberg, Debra A.
    Dohlman, Claes H.
    [J]. CORNEA, 2007, 26 (05) : 564 - 568
  • [9] Hernandez EP, 2004, BIO-MED MATER ENG, V14, P107
  • [10] Khan Bilal F., 2007, International Ophthalmology Clinics, V47, P61, DOI 10.1097/IIO.0b013e318036bd8b