Heat Transfer Coefficients of Film Cooling on a Rotating Turbine Blade Model-Part I: Effect of Blowing Ratio

被引:4
作者
Tao, Zhi [1 ]
Zhao, Zhenming
Ding, Shuiting
Xu, Guoqiang
Yang, Bin
Wu, Hongwei
机构
[1] Beihang Univ, Sch Jet Prop, Dept Engn Thermophys, Beijing 100083, Peoples R China
来源
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME | 2009年 / 131卷 / 04期
关键词
blades; carbon compounds; coolants; cooling; Coriolis force; temperature distribution; turbines; STREAMWISE ANGLES; CROSS-FLOW;
D O I
10.1115/1.3068329
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Experimental investigations were performed to measure the local heat transfer coefficient (h(g)) distributions of film cooling over a flat blade under both stationary and rotating conditions. Film cooling was via a straight circular hole of 4 mm in diameter located in the middle section of the blade angled 30 deg along the streamwise direction and 90 deg along the spanwise direction. The Reynolds (Re-D) number based on the mainstream velocity and the film hole diameter was fixed at 3191, and the rotating speed (omega) was either 0 rpm or 800 rpm; the film cooling blowing ratios ranged from 0.4 to 2.0, and two averaged density ratios of 1.02 and 1.53 were employed with air and carbon dioxide (CO2) as the coolant, respectively. Thermochromic liquid crystal was used to measure the solid surface temperature distributions. Experimental results showed the following: (1) In the stationary case, the blowing ratio has a significant influence on the nondimensional heat transfer coefficient (h(g)/h(0)) especially in the near hole region. (2) The film trajectory in rotation had an obvious deflection in the spanwise direction, and the deflection angles on the suction surface are larger than those on the pressure surface. This was attributed to the combined action of the Coriolis force and centrifugal force. (3) In the rotating case, for CO2 injection, the magnitude of heat transfer coefficient on the pressure surface is reduced compared with the stationary case, and the blowing ratio has smaller effects on h(g)/h(0) distribution. However, on the suction surface, the heat transfer coefficient at x/D < 1.0 is enhanced and then rapidly reduced to be also below the stationary values. For air injection, rotation also depresses the h(g)/h(0) for both the pressure and the suction surface. (4) The density ratio shows a considerable effect on the streamwise heat transfer coefficient distributions especially for the rotating cases.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 15 条
  • [1] AN EXPERIMENTAL-STUDY OF FILM-COOLING IN A ROTATING TRANSONIC TURBINE
    ABHARI, RS
    EPSTEIN, AH
    [J]. JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1994, 116 (01): : 63 - 70
  • [2] THE EFFECT OF DENSITY RATIO ON THE HEAT-TRANSFER COEFFICIENT FROM A FILM-COOLED FLAT-PLATE
    AMMARI, HD
    HAY, N
    LAMPARD, D
    [J]. JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1990, 112 (03): : 444 - 450
  • [3] SMALL DIAMETER FILM COOLING HOLES - WALL CONVECTIVE HEAT-TRANSFER
    ANDREWS, GE
    ALIKHANIZADEH, M
    ASERE, AA
    HUSSAIN, CI
    AZARI, MSK
    MKPADI, MC
    [J]. JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1986, 108 (02): : 283 - 289
  • [4] EKKAD SV, 1995, ASME WINT ANN M SAN
  • [5] ERIKSEN VL, 1974, ASME, V96, P239
  • [6] Han J.C., 2012, Gas Turbine Heat Transfer and Cooling Technology
  • [7] HAY N, 1985, ASME, V107, P105
  • [8] Hyams DG., 1997, 97GT271 ASME
  • [9] Kline S.J., 1952, ASME Mechanical Engineering, V75, P3, DOI DOI 10.1016/J.CHAOS.2005.11.046
  • [10] LLOYD S, 1985, 85GT120 ASME