SNR enhancement of highly-accelerated real-time cardiac MRI acquisitions based on non-local means algorithm

被引:14
作者
Naegel, Benoit [1 ,2 ]
Cernicanu, Alexandru [4 ,5 ]
Hyacinthe, Jean-Noel [4 ,5 ]
Tognolini, Maurizio [3 ]
Vallee, Jean-Paul [4 ,5 ]
机构
[1] Univ Nancy, LORIA, CNRS, UMR 7503, F-54506 Vandoeuvre Les Nancy, France
[2] Univ Appl Sci Western Switzerland HES SO, CH-1202 Geneva, Switzerland
[3] Univ Appl Sci Western Switzerland HES SO, CH-1401 Yverdon, Switzerland
[4] Univ Hosp Geneva, Serv Radiol, CH-1211 Geneva 14, Switzerland
[5] Univ Geneva, Fac Med, CH-1211 Geneva 14, Switzerland
基金
瑞士国家科学基金会;
关键词
Cardiac imaging; Real-time MRI; Registration; Denoising; Non-local means; LEFT-VENTRICULAR FUNCTION; BREATH-HOLD; NOISE REMOVAL; IMAGES; REGISTRATION; MOTION; QUANTIFICATION; MASS;
D O I
10.1016/j.media.2009.05.006
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Real-time cardiac MRI appears as a promising technique to evaluate the mechanical function of the heart. However, ultra-fast MRI acquisitions come with an important signal-to-noise ratio (SNR) penalty, which drastically reduces the image quality. Hence, a real-time denoising approach would be desirable for SNR amelioration. In the clinical context of cardiac dysfunction assessment, long acquisitions are required and for most patients the acquisition takes place with free breathing. Hence, it is necessary to compensate respiratory motion in real-time. In this article, a real-time and interactive method for sequential registration and denoising of real-time MR cardiac images is presented. The method has been experimented on 60 fast MRI acquisitions in five healthy volunteers and five patients. These experiments assessed the feasibility of the method in a real-time context. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:598 / 608
页数:11
相关论文
共 37 条
[1]  
[Anonymous], 2003, Morphological Image Analysis: Principles and Applications
[2]   A review of image denoising algorithms, with a new one [J].
Buades, A ;
Coll, B ;
Morel, JM .
MULTISCALE MODELING & SIMULATION, 2005, 4 (02) :490-530
[3]   An optimized blockwise nonlocal means denoising filter for 3-D magnetic resonance images [J].
Coupe, Pierrick ;
Yger, Pierre ;
Prima, Sylvain ;
Hellier, Pierre ;
Kervrann, Charles ;
Barillot, Christian .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (04) :425-441
[4]  
Coupé P, 2006, LECT NOTES COMPUT SC, V4191, P33
[5]   Wavelet-based de-noising algorithm for images acquired with parallel magnetic resonance imaging (MRI) [J].
Delakis, Ioannis ;
Hammad, Omer ;
Kitney, Richard I. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (13) :3741-3751
[6]   Improvement in the quantification of myocardial perfusion using an automatic spline-based registration algorithm [J].
Dornier, C ;
Ivancevic, MK ;
Thévenaz, P ;
Vallée, JP .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (02) :160-168
[7]   Real-time cine MRI of ventricular septal motion: A novel approach to assess ventricular coupling [J].
Francone, M ;
Dymarkowski, S ;
Kalantzi, M ;
Bogaert, J .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (03) :305-309
[8]   Real-time accelerated interactive MRI with adaptive TSENSE and UNFOLD [J].
Guttman, MA ;
Kellman, P ;
Dick, AJ ;
Lederman, RJ ;
McVeigh, ER .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (02) :315-321
[9]   Rapid evaluation of right and left ventricular function and mass using real-time True-FISP Cine MR imaging without breath-hold: Comparison with segmented True-FISP Cine MR imaging with breath-hold [J].
Hori, Y ;
Yamada, N ;
Higashi, M ;
Hirai, N ;
Nakatani, S .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2003, 5 (03) :439-450
[10]   COMPARING IMAGES USING THE HAUSDORFF DISTANCE [J].
HUTTENLOCHER, DP ;
KLANDERMAN, GA ;
RUCKLIDGE, WJ .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1993, 15 (09) :850-863