The accuracy of free-hand cup positioning -: a CT based measurement of cup placement in 105 total hip arthroplasties

被引:137
作者
Saxler, G
Marx, A
Vandevelde, D
Langlotz, U
Tannast, M
Wiese, M
Michaelis, U
Kemper, G
Grützner, PA
Steffen, R
von Knoch, M
Holland-Letz, T
Bernsmann, K
机构
[1] Univ Duisburg Essen, Dept Orthopaed Surg, D-45122 Essen, Germany
[2] Eeuwfeestklin Antwerpen, Dept Orthopaed Surg, B-2100 Deurne, Belgium
[3] Medivision, CH-4436 Oberdorf, Switzerland
[4] Univ Bern, Dept Orthopaed Surg, CH-3010 Bern, Switzerland
[5] Ruhr Univ Bochum, Dept Orthopaed Surg, D-44791 Bochum, Germany
[6] Alfried Krupp Krankenhaus Essen, Dept Orthopaed Surg, D-45117 Essen, Germany
[7] Dept Surg, D-42109 Wuppertal, Germany
[8] Heidelberg Univ, BG Unfallklin Ludwigshafen, Dept Traumatol, D-67071 Ludwigshafen, Germany
[9] Marienkrankenhaus Kaiserswerth, Dept Orthopaed Surg, D-40348 Dusseldorf, Germany
[10] Ruhr Univ Bochum, Dept Med Informat Biometr & Epidemiol, D-44801 Bochum, Germany
[11] Girardet Klin Essen, Dept Orthopaed Surg, D-45131 Essen, Germany
关键词
D O I
10.1007/s00264-004-0542-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We studied 105 patients who received a total hip arthroplasty between June 1985 and August 2001 using freehand positioning of the acetabular cup. Using pelvic CT scan and the hip-plan module of SurgiGATE-System (Medivision, Oberdorf, Switzerland), we measured the angles of inclination and anteversion of the cup. Mean inclination angle was 45.8degrees+/-10.1degrees (range: 23.0-71.5degrees) and mean anteversion angle was 27.3degrees+/-15.0degrees (range: -23.5degrees to 59.0degrees). We compared the results to the "safe" position as defined by Lewinnek et al. and found that only 27/105 cups were implanted within the limits of the safe position. We conclude that a safe position as defined by Lewinnek et al. [13] was only achieved in a minority of the cups that were implanted freehand.
引用
收藏
页码:198 / 201
页数:4
相关论文
共 21 条
  • [1] Bernsmann K, 2001, Z ORTHOP GRENZGEB, V139, P512
  • [2] 2,012 TOTAL HIP ARTHROPLASTIES - STUDY OF POSTOPERATIVE COURSE AND EARLY COMPLICATIONS
    COVENTRY, MB
    BECKENBAUGH, RD
    NOLAN, DR
    ILSTRUP, DM
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1974, A 56 (02) : 273 - 284
  • [3] HARRIS WH, 1980, CLIN ORTHOP RELAT R, P188
  • [4] HERRLIN K, 1988, ACTA RADIOL, V29, P357
  • [5] Hirakawa K, 2001, CLIN ORTHOP RELAT R, P135
  • [6] Computer assisted measurement of cup placement in total hip replacement
    Jaramaz, B
    DiGioia, AM
    Blackwell, M
    Nikou, C
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (354) : 70 - 81
  • [7] Jaramaz B, 1998, CLIN ORTHOP RELAT R, V355, P8
  • [8] Jolles BM, 2001, INT CONGR SER, V1230, P301
  • [9] Prognosis of dislocation after total hip arthroplasty
    Joshi, A
    Lee, CM
    Markovic, L
    Vlatis, G
    Murphy, JCM
    [J]. JOURNAL OF ARTHROPLASTY, 1998, 13 (01) : 17 - 21
  • [10] Influence of surgical approach on dislocation of total hip replacements
    Kohn, D
    Ruhmann, O
    Wirth, CJ
    [J]. ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1997, 135 (01): : 40 - 44