The Validity and Reliability of Provocation Tests in the Diagnosis of Sacroiliac Joint Dysfunction

被引:0
作者
Telli, Hilal [1 ]
Telli, Serkan [1 ]
Topal, Murat [2 ]
机构
[1] Kastamonu Univ, Tip Fak, Kastamonu, Turkey
[2] Erzurum Reg Training & Res Hosp, Minist Hlth, Erzurum, Turkey
关键词
Dysfunction; lumbar; sacroiliac joint; provocation test; sacroiliac joint pain; pain pattern Pain; LOW-BACK-PAIN; BODY-MASS INDEX; LUMBAR DISC; PART; MANIPULATION; COMPOSITES; PALPATION; PATHOLOGY; GENDER; AGE;
D O I
暂无
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Although sacroiliac joint dysfunction (SIJD) is generally regarded as a source of lumbar pain, its anatomical position and the absence of a diagnostic 'gold standard' lead to difficulties at examination and differential diagnosis. However, since sacroiliac (SI) joint blocks only provide information about pathologies of joint origin and since SIJD developing secondary to pathologies in structures around the joint can be missed. Provocation and palpation tests also need to be used in diagnosis. Objectives: The purpose of this study was to examine the reliability of clinical examination and provocation tests used in the diagnosis of SIJD. Study Design: Retrospective analysis of prospectively collected data. Methods: One hundred and seventeen patients presenting with lumbar and/or leg pain and diagnosed with SIJD through clinical evaluation were included in the study. Range of lumbar joint movement, pain location and specific tests used in the diagnosis of SIJD were evaluated. Positivity in 3 out of 6 provocation tests was adopted as the criterion. Results: 75.2% of patients were female and 24.8% were male. Mean age was 46.41 t 10.45 years. A higher level of females was determined in ender distribution. SIJD was determined on the right in 52.6% of patients and on the left in 47.4%. When SI joint provocation tests were analyzed individually, the highest positivity, in 91.4% patients diagnosed with SIJD, was in the FABER test. The lowest positivity, in 56.4% of patients, was determined in the Ganslen test. The same patients were assessed by the same clinician at 2 different times. In these data, the simple consistence, kappa and PABAK coefficient values of all tests were close to 1 and indicating good agreement. The thigh thrust (POSH) and sacral thrust tests exhibited very good agreement with a kappa coefficient of 0.90 and a PABAK coefficient of 0.92, while the FABER test exhibited good agreement with a kappa coefficient of 0.78 and a PABAK coefficient of 0.92. Limitation: Agreement between different observers was not evaluated, and also no comparison was performed with SI joint injection, regarded as a widely used diagnostic technique. Conclusion: The anatomical position of the SI joint and the lack of a diagnostic 'gold standard' make the examination and diagnosis of SIJD difficult. Most SI joint clinical tests have limited reliability and validity on their own, while a multitest regimen consisting of SI joint pain provocation tests is a reliable method, and these tests can be used instead of unnecessary invasive diagnostic SI joint procedures.
引用
收藏
页码:E367 / E376
页数:10
相关论文
共 50 条
  • [1] Diagnosis of Sacroiliac Joint Pain: Validity of individual provocation tests and composites of tests
    Laslett, M
    Aprill, CN
    McDonald, B
    Young, SB
    MANUAL THERAPY, 2005, 10 (03) : 207 - 218
  • [2] Pain provocation tests for the assessment of sacroiliac joint dysfunction
    Broadhurst, NA
    Bond, MJ
    JOURNAL OF SPINAL DISORDERS, 1998, 11 (04): : 341 - 345
  • [3] Study on sacroiliac joint diagnostics Reliability of functional and pain provocation tests
    von Heymann, Wolfgang
    Moll, Horst
    Rauch, Geraldine
    MANUELLE MEDIZIN, 2018, 56 (03) : 239 - 248
  • [4] THE RELIABILITY OF SELECTED PAIN PROVOCATION TESTS FOR SACROILIAC JOINT PATHOLOGY
    LASLETT, M
    WILLIAMS, M
    SPINE, 1994, 19 (11) : 1243 - 1249
  • [5] Validity and Reliability of Palpatory Clinical Tests of Sacroiliac Joint Mobility: A Systematic Review and Meta-analysis
    Ribeiro, Rafael P.
    Guerrero, Filipe G.
    Camargo, Eduardo N.
    Beraldo, Lucas M.
    Candotti, Claudia T.
    JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2021, 44 (04) : 307 - 318
  • [6] The reliability of selected motion- and pain provocation tests for the sacroiliac joint
    Robinson, Hilde Stendal
    Brox, Jens Ivar
    Robinson, Roar
    Bjelland, Elisabeth
    Solem, Stein
    Telje, Trym
    MANUAL THERAPY, 2007, 12 (01) : 72 - 79
  • [7] Successful Diagnosis of Sacroiliac Joint Dysfunction
    Buchanan, Patrick
    Vodapally, Shashank
    Lee, David W.
    Hagedorn, Jonathan M.
    Bovinet, Christopher
    Strand, Natalie
    Sayed, Dawood
    Deer, Timothy
    JOURNAL OF PAIN RESEARCH, 2021, 14 : 3135 - 3143
  • [8] The reliability of multitest regimens with sacroiliac pain provocation tests
    Kokmeyer, DJ
    van der Wurff, P
    Aufdemkampe, G
    Fickenscher, TCM
    JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2002, 25 (01) : 42 - 48
  • [9] Inter- and intra-examiner reliability of single and composites of selected motion palpation and pain provocation tests for sacroiliac joint
    Arab, Amir Massoud
    Abdollahi, Iraj
    Joghataei, Mohammad Taghi
    Golafshani, Zahra
    Kazemnejad, Anoshirvan
    MANUAL THERAPY, 2009, 14 (02) : 213 - 221
  • [10] Sacroiliac joint mobilization versus gluteus medius strengthening in sacroiliac joint dysfunction
    Younes, Randa M.
    Ayad, Khaled E.
    Fayaz, Nadia A.
    Mohamed, Walid R.
    BIOSCIENCE RESEARCH, 2020, 17 (01): : 406 - 423