Separation and identification of peptides from gel-isolated membrane proteins using a microfabricated device for combined capillary electrophoresis/nanoelectrospray mass spectrometry

被引:119
作者
Li, JJ
Kelly, JF
Chemushevich, I
Harrison, DJ
Thibault, P
机构
[1] Inst Biol Sci, Ottawa, ON K1A 0R6, Canada
[2] SCIEX Ltd, Concord, ON L4K 4V8, Canada
[3] Univ Alberta, Dept Chem, Edmonton, AB T6G 2G2, Canada
关键词
D O I
10.1021/ac990986z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The coupling of microfabricated devices to nanoelectrospray mass spectrometers using both a triple quadrupole and a quadrupole time-of-flight mass spectrometer (QqTOF MS) is presented for the analysis of trace-level membrane proteins. Short disposable nanoelectrospray emitters were directly,coupled to the chip device via a low dead volume connection. The analytical performance of this integrated device-in terms of sensitivity and reproducibility was evaluated for standard peptide mixtures. A concentration detection limit ranging from 3.2 to 43.5 nM for different peptides was achieved in selected ion monitoring, thus representing a 10-fold improvement in sensitivity compared to that of microelectrospray using the same chip/mass spectrometer. Replicate injections indicated that reproducibility of migration time was typically less than 3.1% RSD whereas RSD values of 6-13% were observed on peak areas. Although complete resolution of individual components is not typically achieved for complex digests, the present chip capillary electrophoresis (chip-CE) device enabled proper sample cleanup and partial separation of multicomponent samples prior to mass spectral identification. Analyses of protein digests were typically achieved in less than 1.5 min with peak widths of 1.8-2.5 s (half-height definition) as indicated from individual reconstructed ion electropherograms. The application of this chip-CE/QqTOF MS system is further demonstrated for the identification of membrane proteins which form a subset of the Haemophilus influenzae proteome. Bands first separated by 1D-gel electrophoresis were excised and digested, and extracted tryptic peptides were loaded on the chip without any further sample cleanup or on-line adsorption preconcentration. Accurate molecular mass determination (<5 ppm) in peptide-mapping experiments was obtained by introducing an internal standard via a postseparation channel. The analytical potential of this integrated device for the identification of trace-level proteins from different strains of H. influenzae is demonstrated using both peptide mass-fingerprint database searching and on-line tandem mass spectrometry.
引用
收藏
页码:599 / 609
页数:11
相关论文
共 42 条
  • [1] Bateman KP, 1997, RAPID COMMUN MASS SP, V11, P307
  • [2] Microfluidic devises connected to fused-silica capillaries with minimal dead volume
    Bings, NH
    Wang, C
    Skinner, CD
    Colyer, CL
    Thibault, P
    Harrison, DJ
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (15) : 3292 - 3296
  • [3] DEAMIDATION OF ASPARAGINE AND GLUTAMINE RESIDUES IN PROTEINS AND PEPTIDES - STRUCTURAL DETERMINANTS AND ANALYTICAL METHODOLOGY
    BISCHOFF, R
    KOLBE, HVJ
    [J]. JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 662 (02): : 261 - 278
  • [4] AN APPROACH TO CORRELATE TANDEM MASS-SPECTRAL DATA OF PEPTIDES WITH AMINO-ACID-SEQUENCES IN A PROTEIN DATABASE
    ENG, JK
    MCCORMACK, AL
    YATES, JR
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (11) : 976 - 989
  • [5] MICROMACHINING OF CAPILLARY ELECTROPHORESIS INJECTORS AND SEPARATORS ON GLASS CHIPS AND EVALUATION OF FLOW AT CAPILLARY INTERSECTIONS
    FAN, ZH
    HARRISON, DJ
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (01) : 177 - 184
  • [6] Figeys D, 1998, RAPID COMMUN MASS SP, V12, P1435, DOI 10.1002/(SICI)1097-0231(19981030)12:20<1435::AID-RCM349>3.3.CO
  • [7] 2-0
  • [8] Nanoflow solvent gradient delivery from a microfabricated device for protein identifications by electrospray ionization mass spectrometry
    Figeys, D
    Aebersold, R
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (18) : 3721 - 3727
  • [9] An integrated microfluidics tandem mass spectrometry system for automated protein analysis
    Figeys, D
    Gygi, SP
    McKinnon, G
    Aebersold, R
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (18) : 3728 - 3734
  • [10] WHOLE-GENOME RANDOM SEQUENCING AND ASSEMBLY OF HAEMOPHILUS-INFLUENZAE RD
    FLEISCHMANN, RD
    ADAMS, MD
    WHITE, O
    CLAYTON, RA
    KIRKNESS, EF
    KERLAVAGE, AR
    BULT, CJ
    TOMB, JF
    DOUGHERTY, BA
    MERRICK, JM
    MCKENNEY, K
    SUTTON, G
    FITZHUGH, W
    FIELDS, C
    GOCAYNE, JD
    SCOTT, J
    SHIRLEY, R
    LIU, LI
    GLODEK, A
    KELLEY, JM
    WEIDMAN, JF
    PHILLIPS, CA
    SPRIGGS, T
    HEDBLOM, E
    COTTON, MD
    UTTERBACK, TR
    HANNA, MC
    NGUYEN, DT
    SAUDEK, DM
    BRANDON, RC
    FINE, LD
    FRITCHMAN, JL
    FUHRMANN, JL
    GEOGHAGEN, NSM
    GNEHM, CL
    MCDONALD, LA
    SMALL, KV
    FRASER, CM
    SMITH, HO
    VENTER, JC
    [J]. SCIENCE, 1995, 269 (5223) : 496 - 512