Quantitative evaluation of the administrated dose affecting image quality in myocardial perfusion SPECT

被引:4
作者
El-Gebaly, Reem H. [1 ]
Maamoun, Islam K. [2 ]
Madian, Noha G. [1 ]
机构
[1] Cairo Univ, Fac Sci, Dept Biophys, Cairo, Egypt
[2] Cairo Univ Hosp, Nucl Cardiol Dept, Intens Care Unit, Fac Med, Cairo, Egypt
关键词
99mTc-MIBI; image quality parameters; image quality; qualitative assessment; image contrast; image noise;
D O I
10.3233/XST-140443
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: Myocardial perfusion imaging (MPI) can provide the valuable cardiac functions. Image quality in nuclear medicine tomography is critically dependent on the activity administered into patients. OBJECTIVE: This study was designed to evaluate the optimum injected dose of 99mTc-MIBI for quantitative assessment of image quality as compared with standard injected dose used for that purpose. METHODS: The image quality parameters (Contrast, relative noise and contrast to noise ratio) were determined in 32 patients (21 male, 11 female, age 45-60 y) with weight 60 +/- 15 kg. Patients were classified into four groups; each one consisted of 8 patients. The first group received 370 MBq, the second one received 555 MBq, the third group received 740 MBq and the last group received 925 MBq. RESULTS: Qualitative assessments of the images revealed equivalent scintigraphic patterns in all patients. There was a significant difference in the image contrast. The image contrast in the 370 MBq group was greater than other groups. The image noise between the four groups was significantly different. It increased with injected dose reduction. Contrast to noise ratio (CNR) was significantly different between 370 MBq and other groups. CONCLUSION: It is concluded that results from the first group which received 370 MBq are sufficiently similar to those of the fourth group (standard group) which received 925 MBq. Consequently, accurate estimations of differential cardiac functions are possible with the 370 MBq dose.
引用
收藏
页码:529 / 537
页数:9
相关论文
共 28 条
  • [1] Half-Time SPECT Myocardial Perfusion Imaging with Attenuation Correction
    Ali, Iftikhar
    Ruddy, Terrence D.
    Almgrahi, Abdulaziz
    Anstett, Frank G.
    Wells, R. Glenn
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (04) : 554 - 562
  • [2] [Anonymous], 1998, ANN ICRP, DOI DOI 10.1016/S0146-6453(99)00006-8
  • [3] Butler R., 2013, DABR FDN MED IMAGE Q
  • [4] Chandra R., 2011, NUCL MED PHYS
  • [5] CHANG W, 1979, J NUCL MED, V20, P997
  • [6] Diaz M.P., 2005, J ZHEJIANG U SCI, V7, P947
  • [7] Diaz Marlen P, 2003, J Nucl Med Technol, V31, P216
  • [8] Dickerscheid D., 2013, SPRINGER OPEN J
  • [9] Exercise echocardiography or exercise SPECT imaging? - A meta-analysis of diagnostic test performance
    Fleischmann, KE
    Hunink, MGM
    Kuntz, KM
    Douglas, PS
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1998, 280 (10): : 913 - 920
  • [10] Freiherr G., 2010, DIAGNOSTIC IMAGING