Test-retest reliability of the closed kinetic chain upper extremity stability test: A clinical field test

被引:106
作者
Goldbeck, TG [1 ]
Davies, GJ
机构
[1] Beloit Mem Hosp, Beloit, WI 53551 USA
[2] Univ Wisconsin, La Crosse, WI 54601 USA
[3] Gundersen Lutheran Sports Med, Clin & Res Serv, Onalaska, WI 54650 USA
关键词
closed kinetic chain; upper extremity; functional testing;
D O I
10.1123/jsr.9.1.35
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Context: Functional testing of patients is essential to clinicians because it provides objective data for documentation that can be used for serial reassessment and progression through a rehabilitation program. Furthermore, new tests should require minimal time, space, and money to implement. Purpose: To determine the test-retest reliability of the Closed Kinetic Chain (CKC) Upper Extremity Stability Test. Participants: Twenty-four male college students. Methods: Each subject was tested initially and again 7 days later. Each subject per formed 1 submaximal test followed by 3 maximal efforts. A 45-second rest was given after each 15-second test. The 2 maximal-test scores were averaged and compared with those from the retest. Results:The intraclass correlation coefficient was .922 for test-retest reliability. A paired-samples t test (.927) was conducted, and the coefficient of stability was .859. The results indicate that the CKC Upper Extremity Stability Test is a reliable evaluation tool.