Occupational exposure to desflurane and isoflurane during cardiopulmonary by pass: Is the gas outlet of the membrane oxygenator an operating theatre pollution hazard?

被引:24
作者
Hoerauf, K
Harth, M
Wild, K
Hobbhahn, J
机构
[1] University Hospital, Department of Anaesthesiology (B), University Hospital of Vienna, 1090 Vienna
关键词
anaesthetists; occupational exposure; heart; cardiopulmonary bypass; anaesthetics volatile; isoflurane; desflurane; operating rooms; contamination; equipment; scavenging devices; ANESTHETIC-GASES;
D O I
10.1093/bja/78.4.378
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We have compared occupational exposure to isoflurane and desflurane during cardiopulmonary bypass, with and without a scavenging system at the membrane oxygenator outlet. Trace concentrations of volatile anaesthetics were measured by a direct reading instrument in 40 elective heart surgery procedures. Measurements were obtained in the breathing zones of the anaesthetist and perfusionist. When a scavenging system was used, median desflurane values were less than 0.3 ppm and isoflurane values less than 0.2 ppm. Without a scavenging system values were, in general, three- (isoflurane) to five- (desflurane) fold higher. We conclude that the use of a scavenging system at the membrane oxygenator outlet can reduce occupational exposure to volatile anaesthetics. We therefore recommend routine use of scavenging devices during cardiopulmonary bypass.
引用
收藏
页码:378 / 380
页数:3
相关论文
共 17 条
[1]   TRACE ANESTHETIC EFFECTS ON PERCEPTUAL, COGNITIVE, AND MOTOR SKILLS [J].
BRUCE, DL ;
BACH, MJ ;
ARBIT, J .
ANESTHESIOLOGY, 1974, 40 (05) :453-458
[2]  
COHEN EN, 1971, ANESTHESIOLOGY, V35, P343
[3]   OCCUPATIONAL-DISEASE IN DENTISTRY AND CHRONIC EXPOSURE TO TRACE ANESTHETIC-GASES [J].
COHEN, EN ;
BROWN, BW ;
WU, ML ;
WHITCHER, CE ;
BRODSKY, JB ;
GIFT, HC ;
GREENFIELD, W ;
JONES, TW ;
DRISCOLL, EJ .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1980, 101 (01) :21-31
[4]  
FERSTANDIG LL, 1978, ANESTH ANALG, V57, P328
[5]   FAILURE TO REPLICATE NEGATIVE EFFECTS OF TRACE ANESTHETICS ON MENTAL PERFORMANCE [J].
FRANKHUIZEN, JL ;
VLEK, CAJ ;
BURM, AGL ;
REJGER, V .
BRITISH JOURNAL OF ANAESTHESIA, 1978, 50 (03) :229-234
[6]  
GUIRGUIS SS, 1990, BRIT J IND MED, V47, P490
[7]  
Hoerauf K, 1996, ZBL HYG UMWELTMED, V198, P265
[8]  
Hoerauf KH, 1997, INT ARCH OCC ENV HEA, V69, P134
[9]   Isoflurane waste gas exposure during general anaesthesia: The laryngeal mask compared with tracheal intubation [J].
Hoerauf, KH ;
Koller, C ;
Jakob, W ;
Taeger, L ;
Hobbhahn, J .
BRITISH JOURNAL OF ANAESTHESIA, 1996, 77 (02) :189-193
[10]  
HUBER E, 1994, ANASTH INTENSIVMED, V35, P162