INFLUENCE OF TESTING POSITION ON THE RELIABILITY OF HIP EXTENSOR STRENGTH MEASURED BY A HANDHELD DYNAMOMETER

被引:15
作者
Lue, Yi-Jing [2 ,3 ]
Hsieh, Ching-Lin [4 ]
Liu, Mei-Fang [2 ,3 ]
Hsiao, Shih-Fen [2 ,3 ]
Chen, Shu-Mei [2 ,3 ]
Lin, Jau-Hong [2 ,3 ]
Lu, Yen-Mou [1 ]
机构
[1] Kaohsiung Med Univ Hosp, Dept Orthoped, Kaohsiung 807, Taiwan
[2] Kaohsiung Med Univ Hosp, Dept Phys Med & Rehabil, Kaohsiung 807, Taiwan
[3] Kaohsiung Med Univ, Coll Hlth Sci, Dept Phys Therapy, Kaohsiung, Taiwan
[4] Natl Taiwan Univ, Coll Med, Sch Occupat Therapy, Taipei 10764, Taiwan
关键词
hip extension; positions; reliability; TEST-RETEST RELIABILITY; SMALLEST REAL DIFFERENCE; MUSCLE STRENGTH; PERFORMANCE TESTS; WOMEN; REPRODUCIBILITY; HEMIPARESIS; INTRARATER; PEOPLE; TORQUE;
D O I
10.1016/S1607-551X(09)70051-8
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Hip extensors belong to an important muscle group that controls standing, walking and other functional activities. The prone position (PP) is commonly used to measure the strength of the hip extensors; however, the reliability of such measurements is poor. The aim of this study was to determine the effect of different testing positions, that is, the PP and the prone standing position (PSP), on the reliability of measurements of hip extensor strength. Intrasession reliability and interrater reliability studies were performed on 47 and 16 normal subjects, respectively. The muscle strength of the hip extensors was tested in both the PP and PSP. A handheld dynamometer and break test were used to measure the strength. Relative reliability and absolute reliability were assessed in both PP and PSP. For relative reliability, the intraclass correlation coefficient (JCC) was used to examine the level of reproducibility among measurements. Absolute reliability, the smallest real difference (SRD), was used to provide information on measurement error. The results showed that the reliability was better in PSP than in PP. For relative reliability, the values of JCCs were excellent in the intrasession reliabitity Study, in both PP (ICC1,3 = 0.92) and PSP (ICC1,3 =0.94). However, the interrater reliability was only excellent in PSP; the ICC2,3 were 0.92 in PSP and 0.65 in PR For absolute reliability, the values of the SRD were much lower in PSP (29.8) than in PP (71.8), indicating that the measurement of muscle strength in PSP was more stable and had smaller measurement error than in PP. Changing the testing position from the traditional "prone" to "prone-standing" effectively improved both the relative reliability and the absolute reliability.
引用
收藏
页码:126 / 132
页数:7
相关论文
共 37 条
[1]  
Altman D.G., 1991, PRACTICAL STAT MED R
[2]   Normative values for isometric muscle force measurements obtained with hand-held dynamometers [J].
Andrews, AW ;
Thomas, MW ;
Bohannon, RW .
PHYSICAL THERAPY, 1996, 76 (03) :248-259
[3]   Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine [J].
Atkinson, G ;
Nevill, AM .
SPORTS MEDICINE, 1998, 26 (04) :217-238
[4]   Test position and hip strength in healthy adults and people with chronic stroke [J].
Barbic, Skye ;
Brouwer, Brenda .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2008, 89 (04) :784-787
[5]   Smallest real difference, a link between reproducibility and responsiveness [J].
Beckerman, H ;
Roebroeck, ME ;
Lankhorst, GJ ;
Becher, JG ;
Bezemer, PD ;
Verbeek, ALM .
QUALITY OF LIFE RESEARCH, 2001, 10 (07) :571-578
[6]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[7]   The influence of lower extremity joint torque on gait characteristics in elderly men [J].
Burnfield, JM ;
Josephson, KR ;
Powers, CM ;
Rubenstein, LZ .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2000, 81 (09) :1153-1157
[8]   The test-retest reliability of 2 mobility performance tests in patients with chronic stroke [J].
Chen, Hui-Mei ;
Hsieh, Ching-Lin ;
Lo, Sing Kai ;
Liaw, Lih-Jiun ;
Chen, Shih-Ming ;
Lin, Jau-Hong .
NEUROREHABILITATION AND NEURAL REPAIR, 2007, 21 (04) :347-352
[9]   Hand-held dynamometry for muscle strength measurement in children with cerebral palsy [J].
Crompton, Jodi ;
Galea, Mary P. ;
Phillips, Bev .
DEVELOPMENTAL MEDICINE AND CHILD NEUROLOGY, 2007, 49 (02) :106-111
[10]   What change in isokinetic knee muscle strength can be detected in men and women with hemiparesis after stroke? [J].
Flansbjer, UB ;
Holmbäck, AM ;
Downham, D ;
Lexell, J .
CLINICAL REHABILITATION, 2005, 19 (05) :514-522