The Fluctuation of Intraocular Pressure Measured by a Contact Lens Sensor in Normal-Tension Glaucoma Patients and Nonglaucoma Subjects

被引:49
|
作者
Tojo, Naoki [1 ]
Abe, Shinya [1 ]
Ishida, Masaaki [1 ]
Yagou, Takaaki [1 ]
Hayashi, Atsushi [1 ]
机构
[1] Toyama Univ, Grad Sch Med & Pharmaceut Sci, Dept Ophthalmol, 2630 Sugitani, Toyama 9300194, Japan
关键词
normal-tension glaucoma (NTG); intraocular pressure (IOP); contact lens sensor (CLS); Triggerfish; fluctuation; VISUAL-FIELD PROGRESSION; PRIMARY OPEN-ANGLE; REDUCTION; RISK;
D O I
10.1097/IJG.0000000000000517
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:We compared the fluctuation of intraocular pressure (IOP) in normal-tension glaucoma (NTG) patients and individuals with nonglaucoma eyes. We obtained continuous IOP values using a SENSIMED Triggerfish contact lens sensor.Materials and Methods:The eyes of 12 nonglaucoma subjects and 14 NTG patients were examined. In all 26 subjects, the IOP fluctuation was measured continuously for 24 hours with a contact lens sensor. We evaluated the range of IOP fluctuations over the 24-hour period separately for diurnal IOP and nocturnal IOP and identified each subject's maximum value. The range of IOP fluctuation were analyzed, cutoff level of IOP fluctuation was calculated using receiver operating characteristic curve analyses.Results:The mean IOP in the NTG eyes was 11.52.4 mm Hg and that in the nonglaucoma eyes was 12.7 +/- 2.0 mm Hg, a nonsignificantly difference (P=0.175). The 24-hour range of IOP fluctuations in the NTG group was significantly larger than that of the nonglaucoma group (P=0.007). The percentage of NTG patients who had the peak time of IOP fluctuation during nocturnal sleep was 57.1%, whereas the corresponding rate for the nonglaucoma eyes was 91.7%. The cutoff level of IOP fluctuation for glaucoma was 442 mVeq (sensitivity=1.00; specificity=0.571).Conclusions:The range of IOP fluctuation was larger in the eyes with NTG than in the nonglaucoma eyes. This larger fluctuation might be one of the reasons underlying the aggravation of the visual field by NTG. Measurements of 24-hour continuous IOP might be one of the useful methods to distinguish NTG from nonglaucoma eyes.
引用
收藏
页码:195 / 200
页数:6
相关论文
共 50 条
  • [31] Impact of intraocular pressure reduction on visual field progression in normal-tension glaucoma followed up over 15 years
    Oie, Shinya
    Ishida, Kyoko
    Yamamoto, Tetsuya
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2017, 61 (04) : 314 - 323
  • [32] Implications of Central Corneal Thickness-corrected Intraocular Pressure in Normal-tension Glaucoma with Reduced Central Corneal Thickness
    Lee, Sang Muk
    Baek, Sung Uk
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2023, 64 (09): : 811 - 818
  • [33] Effects of a dorzolamide/timolol fixed combination on diurnal intraocular pressure, heart rate, blood pressure, and ocular perfusion pressure in normal-tension glaucoma
    Lee, Na Young
    Park, Hae-Young Lopilly
    Park, Chan Kee
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2016, 60 (05) : 377 - 382
  • [34] Effect of glaucoma medications on 24-hour intraocular pressure-related patterns using a contact lens sensor
    Mansouri, Kaweh
    Medeiros, Felipe A.
    Weinreb, Robert N.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2015, 43 (09): : 787 - 795
  • [35] Natural History and Risk Factors for Glaucoma Progression in Chinese Patients With Normal-Tension Glaucoma
    Chen, De-Fu
    Wang, Chenmin
    Si, Yuqing
    Lu, Xiaonan
    Zhou, Weihe
    Huang, Qiangjie
    Zuo, Jingjing
    Cheng, Gangwei
    Leung, Dexter Y. L.
    Wang, Ningli
    Friedman, David S.
    Liang, Yuanbo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (03)
  • [36] Nocturnal Variability of Intraocular Pressure Monitored With Contact Lens Sensor Is Associated With Visual Field Loss in Glaucoma
    Yang, Zhiyong
    Mansouri, Kaweh
    Moghimi, Sasan
    Weinreb, Robert N.
    JOURNAL OF GLAUCOMA, 2021, 30 (03) : E56 - E60
  • [37] Adduction induces large optic nerve head deformations in subjects with normal-tension glaucoma
    Chuangsuwanich, Thanadet
    Tun, Tin A.
    Braeu, Fabian A.
    Wang, Xiaofei
    Chin, Zhi Yun
    Panda, Satish K.
    Buist, Martin
    Milea, Dan
    Strouthidis, Nicholas
    Perera, Shamira
    Nongpiur, Monisha Esther
    Aung, Tin
    Girard, Michael J. A.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2024, 108 (04) : 522 - 529
  • [38] Long-Term Intraocular Pressure Fluctuation and Epiretinal Membrane in Patients with Glaucoma or Glaucoma Suspect
    Jung, Kyoung In
    Lee, Jiyun
    Shin, Da Young
    Park, Chan Kee
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (04)
  • [39] Correlation between 24-h continuous intraocular pressure measurement with a contact lens sensor and visual field progression
    Tojo, Naoki
    Hayashi, Atsushi
    Otsuka, Mitsuya
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 258 (01) : 175 - 182
  • [40] Continuous IOP fluctuation recording in normal tension glaucoma patients
    Pajic, Bojan
    Pajic-Eggspuchler, Brigitte
    Haefliger, Ivan
    CURRENT EYE RESEARCH, 2011, 36 (12) : 1129 - 1138