Towards Clinical Application of a Laplace Operator-Based Region of Interest Reconstruction Algorithm in C-Arm CT

被引:10
|
作者
Xia, Yan [1 ,2 ]
Hofmann, Hannes [1 ]
Dennerlein, Frank [3 ]
Mueller, Kerstin [1 ,2 ]
Schwemmer, Chris [1 ,2 ]
Bauer, Sebastian [4 ]
Chintalapani, Gouthami [5 ]
Chinnadurai, Ponraj [5 ]
Hornegger, Joachim [1 ,2 ]
Maier, Andreas [1 ]
机构
[1] Univ Erlangen Nurnberg, Pattern Recognit Lab, D-91058 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Erlangen Grad Sch Adv Opt Technol SAOT, D-91052 Erlangen, Germany
[3] Siemens AG, Healthcare Sect, D-91052 Erlangen, Germany
[4] Siemens AG, Healthcare Sect, D-91301 Forchheim, Germany
[5] Siemens Med Solut USA Inc, Hoffman Estates, IL 60195 USA
关键词
C-arm CT; dose reduction; image reconstruction; region of interest; truncation; truncation artifact; DIGITAL-SUBTRACTION-ANGIOGRAPHY; VOLUME-OF-INTEREST; FLAT-DETECTOR CT; IMAGE-RECONSTRUCTION; HILBERT TRANSFORM; 2D; QUALITY;
D O I
10.1109/TMI.2013.2291622
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
It is known that a reduction of the field-of-view in 3-D X-ray imaging is proportional to a reduction in radiation dose. The resulting truncation, however, is incompatible with conventional reconstruction algorithms. Recently, a novel method for region of interest reconstruction that uses neither prior knowledge nor extrapolation has been published, named approximated truncation robust algorithm for computed tomography (ATRACT). It is based on a decomposition of the standard ramp filter into a 2-D Laplace filtering and a 2-D Radon-based residual filtering step. In this paper, we present two variants of the original ATRACT. One is based on expressing the residual filter as an efficient 2-D convolution with an analytically derived kernel. The second variant is to apply ATRACT in 1-D to further reduce computational complexity. The proposed algorithms were evaluated by using a reconstruction benchmark, as well as two clinical data sets. The results are encouraging since the proposed algorithms achieve a speed-up factor of up to 245 compared to the 2-D Radon-based ATRACT. Reconstructions of high accuracy are obtained, e. g., even real-data reconstruction in the presence of severe truncation achieve a relative root mean square error of as little as 0.92% with respect to nontruncated data.
引用
收藏
页码:593 / 606
页数:14
相关论文
共 13 条
  • [1] Spine segmentation from C-arm CT data sets: application to region-of-interest volumes for spinal interventions
    Buerger, C.
    Lorenz, C.
    Babic, D.
    Hoppenbrouwers, J.
    Homan, R.
    Nachabe, R.
    Racadio, J. M.
    Grass, M.
    MEDICAL IMAGING 2017: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2017, 10135
  • [2] Image reconstruction method based on backprojection filtration algorithm in C-arm computed tomography
    Wang, Xianchao
    Wu, Qilin
    Xu, Pan
    Lu, Zheng
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [3] Fast Dynamic Reconstruction Algorithm with Joint Bilateral Filtering for Perfusion C-arm CT
    Manhart, Michael
    Kowarschik, Markus
    Fieselmann, Andreas
    Yu Deuerling-Zheng
    Hornegger, Joachim
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2304 - 2311
  • [4] GPU based parallel acceleration for fast C-arm cone-beam CT reconstruction
    Chen, Ken
    Wang, Cheng
    Xiong, Jing
    Xie, Yaoqin
    BIOMEDICAL ENGINEERING ONLINE, 2018, 17
  • [5] Time-Resolved Interventional Cardiac C-arm Cone-Beam CT: An Application of the PICCS Algorithm
    Chen, Guang-Hong
    Theriault-Lauzier, Pascal
    Tang, Jie
    Nett, Brian
    Leng, Shuai
    Zambelli, Joseph
    Qi, Zhihua
    Bevins, Nicholas
    Raval, Amish
    Reeder, Scott
    Rowley, Howard
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (04) : 907 - 923
  • [6] Electromagnetic field-based navigation for percutaneous punctures on C-arm CT: experimental evaluation and clinical application
    Bernhard C. Meyer
    Olaf Peter
    Markus Nagel
    Martin Hoheisel
    Bernd B. Frericks
    Karl-Jürgen Wolf
    Frank K. Wacker
    European Radiology, 2008, 18
  • [7] Compressed-sensing-based three-dimensional image reconstruction algorithm for C-arm vascular imaging
    Selim, Mona
    al-Shatouri, Mohammad
    Kudo, Hiroyuki
    Rashed, Essam A.
    2014 CAIRO INTERNATIONAL BIOMEDICAL ENGINEERING CONFERENCE (CIBEC), 2014, : 111 - 114
  • [8] Electromagnetic field-based navigation for percutaneous punctures on C-arm CT: experimental evaluation and clinical application
    Meyer, Bernhard C.
    Peter, Olaf
    Nagel, Markus
    Hoheisel, Martin
    Frericks, Bernd B.
    Wolf, Karl-Juergen
    Wacker, Frank K.
    EUROPEAN RADIOLOGY, 2008, 18 (12) : 2855 - 2864
  • [9] SPATIO-TEMPORALLY REGULARIZED 4-D CARDIOVASCULAR C-ARM CT RECONSTRUCTION USING A PROXIMAL ALGORITHM
    Taubmann, Oliver
    Unberath, Mathias
    Lauritsch, Guenter
    Achenbach, Stephan
    Maier, Andreas
    2017 IEEE 14TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2017), 2017, : 52 - 55
  • [10] Compressed-sensing-based content-driven hierarchical reconstruction: Theory and application to C-arm cone-beam tomography
    Langet, Helene
    Riddell, Cyril
    Reshef, Aymeric
    Trousset, Yves
    Tenenhaus, Arthur
    Lahalle, Elisabeth
    Fleury, Gilles
    Paragios, Nikos
    MEDICAL PHYSICS, 2015, 42 (09) : 5222 - 5237