Automatic 3D aortic annulus sizing by computed tomography in the planning of transcatheter aortic valve implantation

被引:26
|
作者
Queiros, Sandro [1 ,2 ,3 ]
Dubois, Christophe [1 ,4 ]
Morais, Pedro [1 ,2 ,5 ]
Adriaenssens, Tom [1 ,4 ]
Fonseca, Jaime C. [3 ]
Vilaca, Joao L. [2 ,6 ]
D'hooge, Jan [1 ]
机构
[1] Katholieke Univ Leuven, Dept Cardiovasc Sci, Leuven, Belgium
[2] ICVS 3Bs PT Govt Associate Lab, Braga, Guimaraes, Portugal
[3] Univ Minho, Sch Engn, Algoritmi Ctr, Guimaraes, Portugal
[4] Univ Hosp Leuven, Dept Cardiovasc Dis, Leuven, Belgium
[5] Univ Porto, INEGI, Fac Engn, Oporto, Portugal
[6] Polytech Inst Cavado & Ave, DIGARC, Barcelos, Portugal
关键词
Computed tomography; TAVI; Aortic valve sizing; Fully automatic analysis; Semi-automatic analysis; 3-DIMENSIONAL TRANSESOPHAGEAL ECHOCARDIOGRAPHY; REPLACEMENT; SEGMENTATION; ROOT; DIMENSIONS; SELECTION; STENOSIS; TAVR;
D O I
10.1016/j.jcct.2016.12.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Accurate imaging assessment of aortic annulus (AoA) dimension is paramount to decide on the correct transcatheter heart valve (THV) size for patients undergoing transcatheter aortic valve implantation (TAVI). We evaluated the feasibility and accuracy of a novel automatic framework for multi detector row computed tomography (MDCT)-based TAVI planning. Methods: Among 122 consecutive patients undergoing TAVI and retrospectively reviewed for this study, 104 patients with preoperative MDCT of sufficient quality were enrolled and analyzed with the proposed software. Fully automatic (FA) and semi-automatic (SA) AoA measurements were compared to manual measurements, with both automated and manual-based interobserver variability (IOV) being assessed. Finally, the effect of these measures on hypothetically selected THV size was evaluated against the implanted size, as well as with respect to manually-derived sizes. Results: FA analysis was feasible in 92.3% of the cases, increasing to 100% if using the SA approach. Automatically-extracted measurements showed excellent agreement with manually-derived ones, with small biases and narrow limits of agreement, and comparable to the interobserver agreement. The SA approach presented a statistically lower IOV than manual analysis, showing the potential to reduce interobserver sizing disagreements. Moreover, the automated approaches displayed close agreement with the implanted sizes, similar to the ones obtained by the experts. Conclusion: The proposed automatic framework provides an accurate and robust tool for AoA measurements and THV sizing in patients undergoing TAVI. (C) 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:25 / 32
页数:8
相关论文
共 50 条
  • [41] A novel contribution towards coherent and reproducible intravalvular measurement of the aortic annulus by multidetector computed tomography ahead of transcatheter aortic valve implantation
    Dennenthon, Julie
    Rioufol, Gilles
    Obadia, Jean-Francois
    Vergnat, Mathieu
    Green, Lisa
    Croisille, Pierre
    Boussel, Loic
    Peron, Julien
    Revel, Didier
    Finet, Gerard
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2015, 108 (05) : 281 - 292
  • [42] Impact of Valve Over-Sizing After Transcatheter Aortic Valve Implantation With a Self-Expanding Valve: A Multislice Computed Tomography Study
    Drakopoulou, Maria
    Toutouzas, Konstantinos
    Stathogiannis, Konstantinos
    Latsios, George
    Sideris, Skevos
    Xanthopoulou, Maria
    Penesopoulou, Vicky
    Trantalis, George
    Synetos, Andreas
    Papanikolaou, Angelos
    Aggeli, Constantina
    Vavuranakis, Manolis
    Tousoulis, Dimitrios
    JOURNAL OF INVASIVE CARDIOLOGY, 2019, 31 (05): : E76 - E82
  • [43] Transcatheter Aortic Valve Implantation in Patients With Severe Aortic Stenosis and Small Aortic Annulus
    Kalavrouziotis, Dimitri
    Rodes-Cabau, Josep
    Bagur, Rodrigo
    Doyle, Daniel
    De Larochelliere, Robert
    Pibarot, Philippe
    Dumont, Eric
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (10) : 1016 - 1024
  • [44] Automated 3-Dimensional Aortic Annular Assessment by Multidetector Computed Tomography in Transcatheter Aortic Valve Implantation
    Watanabe, Yusuke
    Morice, Marie-Claude
    Bouvier, Erik
    Leong, Tora
    Hayashida, Kentaro
    Lefevre, Thierry
    Hovasse, Thomas
    Romano, Mauro
    Chevalier, Bernard
    Donzeau-Gouge, Patrick
    Farge, Arnaud
    Cormier, Bertrand
    Garot, Philippe
    JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (09) : 955 - 964
  • [45] Computed tomography in the evaluation for transcatheter aortic valve implantation (TAVI)
    Schoenhagen, Paul
    Hausleiter, Joerg
    Achenbach, Stephan
    Desai, Milind Y.
    Tuzcu, E. Murat
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2011, 1 (01) : 44 - 56
  • [46] The Functional Aortic Annulus in the 3D Era: Focus on Transcatheter Aortic Valve Replacement for the Perioperative Echocardiographer
    Patel, Prakash A.
    Gutsche, Jacob T.
    Vernick, William J.
    Giri, Jay S.
    Ghadimi, Kamrouz
    Weiss, Stuart J.
    Jagasia, Dinesh H.
    Bavaria, Joseph E.
    Augoustides, John G. T.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2015, 29 (01) : 240 - 245
  • [47] Multidetector computed tomography in Transcatheter aortic valve implantation. Where we stand
    Al-Hassan, D.
    Blanke, P.
    Leipsic, J.
    MINERVA CARDIOANGIOLOGICA, 2013, 61 (04): : 407 - 427
  • [48] A method to determine suitable fluoroscopic projections for transcatheter aortic valve implantation by computed tomography
    Arnold, Martin
    Achenbach, Stephan
    Pfeiffer, Ina
    Ensminger, Stephan
    Marwan, Mohamed
    Einhaus, Friedrich
    Pflederer, Tobias
    Ropers, Dieter
    Schuhbaeck, Annika
    Anders, Katharina
    Lell, Michael
    Uder, Michael
    Ludwig, Josef
    Weyand, Michael
    Daniel, Werner G.
    Feyrer, Richard
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (06) : 422 - 428
  • [49] Multimodal Assessment of the Aortic Annulus Diameter Implications for Transcatheter Aortic Valve Implantation
    Messika-Zeitoun, David
    Serfaty, Jean-Michel
    Brochet, Eric
    Ducrocq, Gregory
    Lepage, Laurent
    Detaint, Delphine
    Hyafil, Fabien
    Himbert, Dominique
    Pasi, Nicoletta
    Laissy, Jean-Pierre
    Iung, Bernard
    Vahanian, Alec
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (03) : 186 - 194
  • [50] The application of 3D printing in preoperative planning for transcatheter aortic valve replacement: a systematic review
    Xenofontos, Paris
    Zamani, Reza
    Akrami, Mohammad
    BIOMEDICAL ENGINEERING ONLINE, 2022, 21 (01)