Automatic 3D aortic annulus sizing by computed tomography in the planning of transcatheter aortic valve implantation

被引:26
|
作者
Queiros, Sandro [1 ,2 ,3 ]
Dubois, Christophe [1 ,4 ]
Morais, Pedro [1 ,2 ,5 ]
Adriaenssens, Tom [1 ,4 ]
Fonseca, Jaime C. [3 ]
Vilaca, Joao L. [2 ,6 ]
D'hooge, Jan [1 ]
机构
[1] Katholieke Univ Leuven, Dept Cardiovasc Sci, Leuven, Belgium
[2] ICVS 3Bs PT Govt Associate Lab, Braga, Guimaraes, Portugal
[3] Univ Minho, Sch Engn, Algoritmi Ctr, Guimaraes, Portugal
[4] Univ Hosp Leuven, Dept Cardiovasc Dis, Leuven, Belgium
[5] Univ Porto, INEGI, Fac Engn, Oporto, Portugal
[6] Polytech Inst Cavado & Ave, DIGARC, Barcelos, Portugal
关键词
Computed tomography; TAVI; Aortic valve sizing; Fully automatic analysis; Semi-automatic analysis; 3-DIMENSIONAL TRANSESOPHAGEAL ECHOCARDIOGRAPHY; REPLACEMENT; SEGMENTATION; ROOT; DIMENSIONS; SELECTION; STENOSIS; TAVR;
D O I
10.1016/j.jcct.2016.12.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Accurate imaging assessment of aortic annulus (AoA) dimension is paramount to decide on the correct transcatheter heart valve (THV) size for patients undergoing transcatheter aortic valve implantation (TAVI). We evaluated the feasibility and accuracy of a novel automatic framework for multi detector row computed tomography (MDCT)-based TAVI planning. Methods: Among 122 consecutive patients undergoing TAVI and retrospectively reviewed for this study, 104 patients with preoperative MDCT of sufficient quality were enrolled and analyzed with the proposed software. Fully automatic (FA) and semi-automatic (SA) AoA measurements were compared to manual measurements, with both automated and manual-based interobserver variability (IOV) being assessed. Finally, the effect of these measures on hypothetically selected THV size was evaluated against the implanted size, as well as with respect to manually-derived sizes. Results: FA analysis was feasible in 92.3% of the cases, increasing to 100% if using the SA approach. Automatically-extracted measurements showed excellent agreement with manually-derived ones, with small biases and narrow limits of agreement, and comparable to the interobserver agreement. The SA approach presented a statistically lower IOV than manual analysis, showing the potential to reduce interobserver sizing disagreements. Moreover, the automated approaches displayed close agreement with the implanted sizes, similar to the ones obtained by the experts. Conclusion: The proposed automatic framework provides an accurate and robust tool for AoA measurements and THV sizing in patients undergoing TAVI. (C) 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:25 / 32
页数:8
相关论文
共 50 条
  • [1] Conformational Pulsatile Changes of the Aortic Annulus Impact on Prosthesis Sizing by Computed Tomography for Transcatheter Aortic Valve Replacement
    Blanke, Philipp
    Russe, Maximillian
    Leipsic, Jonathon
    Reinoehl, Jochen
    Ebersberger, Ullrich
    Suranyi, Pal
    Siepe, Matthias
    Pache, Gregor
    Langer, Mathias
    Schoepf, U. Joseph
    JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (09) : 984 - 994
  • [2] Manual versus automatic detection of aortic annulus plane in a computed tomography scan for transcatheter aortic valve implantation screeningaEuro
    Van Linden, Arnaud
    Kempfert, Joerg
    Blumenstein, Johannes
    Moellmann, Helge
    Kim, Won-Keun
    Alkaya, Serap
    Hamm, Christian
    Walther, Thomas
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2014, 46 (02) : 207 - 212
  • [3] Aortic Annulus Evaluation in Transcatheter Aortic Valve Implantation
    Hutter, Andrea
    Opitz, Anke
    Bleiziffer, Sabine
    Ruge, Hendrik
    Hettich, Ina
    Mazzitelli, Domenico
    Will, Albrecht
    Tassani, Peter
    Bauernschmitt, Robert
    Lange, Ruediger
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 76 (07) : 1009 - 1019
  • [4] Multidetector Computed Tomography in Transcatheter Aortic Valve Implantation
    Leipsic, Jonathon
    Gurvitch, Ronen
    LaBounty, Troy M.
    Min, James K.
    Wood, David
    Johnson, Mark
    Ajlan, Amr M.
    Wijesinghe, Namal
    Webb, John G.
    JACC-CARDIOVASCULAR IMAGING, 2011, 4 (04) : 416 - 429
  • [5] Balloon vs Computed Tomography Sizing of the Aortic Annulus for Transcatheter Aortic Valve Replacement
    Condado, Jose F.
    Stewart, James
    Jensen, Hanna A.
    Lerakis, Stamatios
    Ko, Sung Min
    Stillman, Arthur
    Rajaei, Mohammad H.
    Mavromatis, Kreton
    Devireddy, Chandan
    Sarin, Eric
    Leshnower, Bradley G.
    Guyton, Robert
    Kaebnick, Brian
    Syed, Amjad
    Thourani, Vinod
    Block, Peter C.
    Babaliaros, Vasilis
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B267 - B268
  • [6] Validation of 3D-reconstructed computed tomography images using OsiriX® software for pre-transcatheter aortic valve implantation aortic annulus sizing
    Gumsheimer, Marlena
    Stortecky, Stefan
    Gahl, Brigitta
    Langhammer, Bettina
    Carrel, Thierry
    Buellesfeld, Lutz
    Huber, Christoph
    Most, Henriette
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2017, 25 (02) : 198 - 205
  • [7] Role of Preprocedural Computed Tomography in Transcatheter Aortic Valve Implantation
    Lehmkuhl, L.
    Foldyna, B.
    Haensig, M.
    von Aspern, K.
    Luecke, C.
    Andres, C.
    Grothoff, M.
    Riese, F.
    Nitzsche, S.
    Holzhey, D.
    Linke, A.
    Mohr, F. -W.
    Gutberlet, M.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2013, 185 (10): : 941 - 949
  • [8] 3D printing of the aortic annulus based on cardiovascular computed tomography: Preliminary experience in pre-procedural planning for aortic valve sizing
    Faletti, Riccardo
    Gatti, Marco
    Cosentino, Aurelio
    Bergamasco, Laura
    Stura, Erik Cura
    Garabello, Domenica
    Pennisi, Giovanni
    Salizzoni, Stefano
    Veglia, Simona
    Ottavio, Davini
    Rinaldi, Mauro
    Fonio, Paolo
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2018, 12 (05) : 391 - 397
  • [9] Aortic Annulus Diameter Determination by Multidetector Computed Tomography Reproducibility, Applicability, and Implications for Transcatheter Aortic Valve Implantation
    Gurvitch, Ronen
    Webb, John G.
    Yuan, Ren
    Johnson, Mark
    Hague, Cameron
    Willson, Alexander B.
    Toggweiler, Stefan
    Wood, David A.
    Ye, Jian
    Moss, Robert
    Thompson, Christopher R.
    Achenbach, Stephan
    Min, James K.
    LaBounty, Troy M.
    Cury, Ricardo
    Leipsic, Jonathon
    JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (11) : 1235 - 1245
  • [10] Automated 3D Analysis of Multislice Computed Tomography to Define the Line of Perpendicularity of the Aortic Annulus and of the Implanted Valve: Benefit on Planning Transcatheter Aortic Valve Replacement
    Samin, Mariam
    Juthier, Francis
    Van Belle, Camille
    Agostoni, Pierfrancesco
    Kluin, Jolanda
    Stella, Pieter R.
    Ramjankhan, Faiez
    Budde, Ricardo P. J.
    Sieswerda, Gertjan
    Algeri, Emanuela
    Elkalioubie, Ahmed
    Belkacemi, Anouar
    Bertrand, Michel E.
    Doevendans, Pieter A.
    Van Belle, Eric
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 83 (01) : E119 - E127