COMPARATIVE ANALYSIS OF APICAL EXTRUSION OF DEBRIS AND SHAPING ABILITY IN CURVED ROOT CANALS USING FOUR DIFFERENT NITI INSTRUMENTS

被引:0
作者
Sheng, Qing [1 ]
LI, Wen [1 ]
Yu, Yijun [1 ]
Liu, Hanxiao [1 ]
Qiu, Xinyi [1 ]
Zhu, Bijun [1 ]
Tang, Xuna [1 ]
Miao, Leiying [1 ]
机构
[1] Nanjing Univ, Med Sch, Nanjing Stomatol Hosp, Dept Endodont, Zhongyang Rood 30, Nanjing 210008, Peoples R China
来源
ACTA MEDICA MEDITERRANEA | 2022年 / 38卷 / 02期
关键词
Apical extrusion; Apical transportation; Centering ration; Root Canal Preparation; RECIPROCATING SINGLE-FILE; FULL-SEQUENCE ROTARY; EXTRUDED DEBRIS; NICKEL-TITANIUM; M-WIRE; SYSTEMS; TRANSPORTATION;
D O I
10.19193/0393-6384_2022_2_196
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The aim of this study was to evaluate the apical extrusion of debris, apical transportation (AT) and centering ratio (CR) after root canal preparation using Reciproc, ProTaper, ProTaper Next (PTN) and Revo-S. Materials and methods: Sixty extracted human mandibular premolars with a curvature angle of 25 degrees and the same length were randomly divided into four groups (n=15). All root canals were shaped to size of 25: ProTaper Next X2 (Dentsply Maillefer), Reciproc (R25; VDW, Munich, Germany), Revo-S SU (25#, .06; MicroMega, Besancon, France) and ProTaper F2 (25#, .08; Dentsply Maillefer, Ballaigues, Switzerland). All roots were sectioned perpendicularly at 1, 3, 5 and 7 mm from the apex and were scanned by a micro-CT before and after the preparation. During this process, collect the debris of each tooth and weigh it three times consecutively. The amount of apical debris extrusion, AT and CR of teeth were recorded and compared between the groups by using the Kruskal-Wallis test. Results: In terms of extruded debris, all specimens showed apical debris extrusion, and no statistically significant difference was obtained among them (P>.05). In terms of transportation, there was no significant difference among the four groups (P >0.05); in terms of centering ratio, PTN and Revo-S had significantly higher (closer to C=1) centreing ratios than Reciproc and ProTaper. There was a significant difference between PTN and ProTaper (P<0.05), PTN and Reciproc (P<0.05), ProTaper and Revo-S (P<0.05) at 3 mm and 5 mm from the apical surface, but there was no significant difference in the mean centering ratio at 1 mm or 7 mm from the apical surface among the four groups. Conclusion: ProTaper Next and Revo-S prepared a more centered root canal shapes. All instruments caused extrusion of debris through the apex.
引用
收藏
页码:1289 / 1296
页数:8
相关论文
共 28 条
  • [1] Evaluation of Cyclic Flexural Fatigue of M-Wire Nickel-Titanium Rotary Instruments
    Al-Hadlaq, Solaiman M. S.
    AlJarbou, Fahad A.
    AlThumairy, Riyadh I.
    [J]. JOURNAL OF ENDODONTICS, 2010, 36 (02) : 305 - 307
  • [2] Assessment of the apically extruded debris between a rotary system, a reciprocating system and hand files during the root canal instrumentation of the deciduous molars
    Alnassar, Ibrahim
    Alsafadi, Ahmad Saleem
    Kouchaji, Chaza
    [J]. DENTAL AND MEDICAL PROBLEMS, 2019, 56 (01) : 53 - 57
  • [3] Debris extrusion and foraminal deformation produced by reciprocating instruments made of thermally treated NiTi wires
    Arcanjo Frota, Myrna Maria
    Bernardes, Ricardo Affonso
    Vivan, Rodrigo Ricci
    Vivacqua-Gomes, Nilton
    Hungaro Duarte, Marco Antonio
    de Vasconcelos, Bruno Carvalho
    [J]. JOURNAL OF APPLIED ORAL SCIENCE, 2018, 26
  • [4] Arora Anshul, 2014, J Conserv Dent, V17, P35, DOI 10.4103/0972-0707.124127
  • [5] A Stereomicroscopic Evaluation of Dentinal Cracks at Different Instrumentation Lengths by Using Different Rotary Files (ProTaper Universal, ProTaper Next, and HyFlex CM): An Ex Vivo Study
    Ashraf, Fauzia
    Shankarappa, Pushpa
    Misra, Abhinav
    Sawhney, Asheesh
    Sridevi, Nandamuri
    Singh, Anu
    [J]. SCIENTIFICA, 2016, 2016
  • [6] Root Canal Area Increase Promoted by the EndoSequence and ProTaper Systems: Comparison by Computed Tomography
    Bernardes, Ricardo Affonso
    Rocha, Emerson Antunes
    Hungaro Duarte, Marco Antonio
    Vivan, Rodrigo Ricci
    de Moraes, Ivaldo Gomes
    Bramante, Alexandre S.
    de Azevedo, Jose Ribamar
    [J]. JOURNAL OF ENDODONTICS, 2010, 36 (07) : 1179 - 1182
  • [7] Shaping ability and cleaning effectiveness of two single-file systems in severely curved root canals of extracted teeth: Reciproc and WaveOne versus Mtwo and ProTaper
    Buerklein, S.
    Hinschitza, K.
    Dammaschke, T.
    Schaefer, E.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2012, 45 (05) : 449 - 461
  • [8] Apically Extruded Debris with Reciprocating Single-File and Full-sequence Rotary Instrumentation Systems
    Buerklein, Sebastian
    Schaefer, Edgar
    [J]. JOURNAL OF ENDODONTICS, 2012, 38 (06) : 850 - 852
  • [9] Comparative Study of Different Novel Nickel-Titanium Rotary Systems for Root Canal Preparation in Severely Curved Root Canals
    Capar, Ismail Davut
    Ertas, Huseyin
    Ok, Evren
    Arslan, Hakan
    Ertas, Elif Tarim
    [J]. JOURNAL OF ENDODONTICS, 2014, 40 (06) : 852 - 856
  • [10] Assessment of apically extruded debris produced by the single-file ProTaper F2 technique under reciprocating movement
    De-Deus, Gustavo
    Brandao, Maria Claudia
    Barino, Bianca
    Di Giorgi, Karina
    Sergio Fidel, Rivail Antonio
    Luna, Aderval Severino
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2010, 110 (03): : 390 - 394