Use of the internal standardization for difficult sampling by graphite furnace atomic absorption spectrometry

被引:17
|
作者
Oliveira, AP
Neto, JAG
Nóbrega, JA
Oliveira, PV
机构
[1] Univ Estadual Paulista, Dept Quim Anal, BR-14801970 Araraquara, SP, Brazil
[2] Univ Fed Sao Carlos, Dept Quim, BR-13560970 Sao Carlos, SP, Brazil
[3] Univ Sao Paulo, Inst Quim, BR-05513970 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
internal standardization; graphite furnace atomic absorption spectrometry; complex matrices; sparkling waters;
D O I
10.1016/j.talanta.2004.02.032
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work shows the potentiality of As as internal standard to compensate errors from sampling of sparkling drinking water samples in the determination of selenium by graphite furnace atomic absorption spectrometry. The mixture Pd(NO3)(2)/Mg(NO3)(2) was used as chemical modifier. All samples and reference solutions were automatically spiked with 500 mug l(-1) As and 0.2% (v/v) HNO3 by the autosampler, eliminating the need for manual dilutions. For 10 mul dispensed sample into the graphite tube, a good correlation (r = 0.9996) was obtained between the ratio of analyte absorbance by the internal standard absorbance and the analyte concentrations. The relative standard deviations (R.S.D.) of measurements varied from 0.05 to 2% and from 1.9 to 5% (n = 12) with and without internal standardization, respectively. The limit of detection (LD) based on integrated absorbance was 3.0 mug l(-1) Se. Recoveries in the 94-109% range for Se spiked samples were obtained. Internal standardization (IS) improved the repeatability of measurements and increased the lifetime of the graphite tube in ca. 15%. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:334 / 337
页数:4
相关论文
共 50 条
  • [21] Degradation Process of Graphite Furnace Estimated from the Atomic Gas Temperature of Iron in Graphite Furnace Atomic Absorption Spectrometry
    Ashino, Tetsuya
    Shimabukuro, Haruki
    Wagatsuma, Kazuaki
    MATERIALS TRANSACTIONS, 2010, 51 (12) : 2215 - 2219
  • [22] The use of chemical modifiers in the determination of cadmium in sewage sludge and tin in PVC by solid sampling-graphite furnace atomic absorption spectrometry
    Belarra, MA
    Resano, M
    Rodríguez, S
    Urchaga, J
    Castillo, JR
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (05) : 787 - 795
  • [23] Determination of lead and cadmium in wines by graphite furnace atomic absorption spectrometry
    Kim, M
    FOOD ADDITIVES AND CONTAMINANTS, 2004, 21 (02): : 154 - 157
  • [24] Research Advance in Slurry Introduction for Graphite Furnace Atomic Absorption Spectrometry
    Lu Gui-ping
    Wang Zheng
    Qiu De-ren
    Zou Hui-jun
    He Yan-feng
    Yang Peng-yuan
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 30 (08) : 2253 - 2259
  • [25] Solid sampling-graphite furnace atomic absorption spectrometry for the direct determination of silver at trace and ultratrace levels
    Resano, M
    Aramendía, M
    García-Ruiz, E
    Crespo, C
    Belarra, MA
    ANALYTICA CHIMICA ACTA, 2006, 571 (01) : 142 - 149
  • [26] Sizing silver nanoparticles in chicken meat using direct slurry sampling graphite furnace atomic absorption spectrometry
    Brucker, Dominic
    Leopold, Kerstin
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (19) : 4551 - 4558
  • [27] Determination of selenium in the human brain by graphite furnace atomic absorption spectrometry
    Ejima, A
    Watanabe, C
    Koyama, H
    Matsuno, K
    Satoh, H
    BIOLOGICAL TRACE ELEMENT RESEARCH, 1996, 54 (01) : 9 - 21
  • [28] Systematic study of boron determination by graphite furnace atomic absorption spectrometry
    Kobayashi, R
    Okamura, S
    Yamada, K
    Kudo, M
    ANALYTICAL SCIENCES, 1997, 13 : 31 - 34
  • [29] Sizing silver nanoparticles in chicken meat using direct slurry sampling graphite furnace atomic absorption spectrometry
    Dominic Brucker
    Kerstin Leopold
    Analytical and Bioanalytical Chemistry, 2019, 411 : 4551 - 4558
  • [30] Direct sampling graphite furnace atomic absorption spectrometry - feasibility of Na and K determination in desalted crude oil
    Seeger, Tassia S.
    Machado, Eduarda Q.
    Flores, Erico M. M.
    Mello, Paola A.
    Duarte, Fabio A.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 141 : 28 - 33