Diagnostic accuracy of late iodine enhancement on cardiac computed tomography with a denoise filter for the evaluation of myocardial infarction

被引:12
|
作者
Matsuda, Takuya [1 ]
Kido, Teruhito [1 ]
Itoh, Toshihide [2 ]
Saeki, Hideyuki [3 ]
Shigemi, Susumu [3 ]
Watanabe, Kouki [3 ]
Kido, Tomoyuki [4 ]
Aono, Shoji [4 ]
Yamamoto, Masaya [4 ]
Matsuda, Takeshi [5 ]
Mochizuki, Teruhito [1 ]
机构
[1] Ehime Univ, Grad Sch Med, Dept Radiol, Toon, Ehime 7910295, Japan
[2] Siemens Japan, Res & Collaborat, Shinagawa Ku, Tokyo, Japan
[3] Saiseikai Matsuyama Hosp, Dept Cardiol, Matsuyama, Ehime, Japan
[4] Saiseikai Matsuyama Hosp, Dept Radiol, Matsuyama, Ehime, Japan
[5] Matsuyama Red Cross Hosp, Dept Radiol, Matsuyama, Ehime, Japan
关键词
Acute myocardial infarction; Cardiac computed tomography; Image postprocessing; Late iodine enhancement; CORONARY-ANGIOGRAPHY; CT; PREDICTION; VIABILITY; MRI;
D O I
10.1007/s10554-015-0716-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We evaluated the image quality and diagnostic performance of late iodine enhancement (LIE) in dual-source computed tomography (DSCT) with low kilo-voltage peak (kVp) images and a denoise filter for the detection of acute myocardial infarction (AMI) in comparison with late gadolinium enhancement (LGE) magnetic resonance imaging (MRI). The Hospital Ethics Committee approved the study protocol. Before discharge, 19 patients who received percutaneous coronary intervention after AMI underwent DSCT and 1.5 T MRI. Immediately after coronary computed tomography (CT) angiography, contrast medium was administered at a slow injection rate. LIE-CT scans were acquired via dual-energy CT and reconstructed as 100-, 140-kVp, and mixed images. An iterative three-dimensional edge-preserved smoothing filter was applied to the 100-kVp images to obtain denoised 100-kVp images. The mixed, 140-kVp, 100-kVp, and denoised 100-kVp images were assessed using contrast-to-noise ratio (CNR), and their diagnostic performance in comparison with MRI and infarcted volumes were evaluated. Three hundred four segments of 19 patients were evaluated. Fifty-three segments showed LGE in MRI. The median CNR of the mixed, 140-, 100-kVp and denoised 100-kVp images was 3.49, 1.21, 3.57, and 6.08, respectively. The median CNR was significantly higher in the denoised 100-kVp images than in the other three images (P < 0.05). The denoised 100-kVp images showed the highest diagnostic accuracy and sensitivity. The percentage of myocardium in the four CT image types was significantly correlated with the respective MRI findings. The use of a denoise filter with a low-kVp image can improve CNR, sensitivity, and accuracy in LIE-CT.
引用
收藏
页码:177 / 185
页数:9
相关论文
共 50 条
  • [41] Myocardial iodine concentration measurement using dual-energy computed tomography for the diagnosis of cardiac amyloidosis: a pilot study
    Chevance, Virgile
    Damy, Thibaud
    Tacher, Vania
    Legou, Francois
    Ridouani, Fourat
    Luciani, Alain
    Kobeiter, Hicham
    Rahmouni, Alain
    Deux, Jean-Francois
    EUROPEAN RADIOLOGY, 2018, 28 (02) : 816 - 823
  • [42] Myocardial Infarction in the Absence of Obstructive Coronary Artery Disease Due to Coronary Embolism Clarified by Cardiac Computed Tomography
    Yoshihara, Shu
    Matsunaga, Masaki
    Yaegashi, Taku
    Nozue, Sadanori
    Naito, Masaaki
    CIRCULATION-CARDIOVASCULAR IMAGING, 2023, 16 (12) : 998 - 1001
  • [43] Evaluation of acute myocardial infarction with late enhancement pattern on MRI compared with 201TI and 99mTc-Hydroxymethylenediphosphonate (HMDP) dual single photon emission computed tomography (SPECT) images
    Nagao, Michinobu
    Higashino, Hiroshi
    Matsuoka, Hiroshi
    Kawakami, Hideo
    Miyagawa, Masao
    Mochizuki, Teruhito
    Uemura, Masahiko
    Tokunaga, Nobuko
    INVESTIGATIVE RADIOLOGY, 2007, 42 (11) : 765 - 770
  • [44] The Diagnostic Accuracy of 64-Detector Cardiac Computed Tomography Compared With Stress Nuclear Imaging in Patients Undergoing Invasive Cardiac Catheterization
    Hamirani, Yasmin S.
    Isma'eel, Hussain
    Larijani, Vahid
    Drury, Paul
    Lim, Wayland
    Bevinal, Manzoor
    Saeed, Anila
    Ahmadi, Nasser
    Karlsberg, Ronald P.
    Budoff, Matthew J.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (05) : 645 - 651
  • [45] Enhancement patterns detected by multidetector computed tomography are associated with the long-term prognosis of patients with acute myocardial infarction
    Koichi Tamita
    Atsushi Yamamuro
    Hiromi Hashimura
    Mika Maeda
    Takeshi Tokuda
    Kazunori Yoshida
    Yasuhiro Izumiya
    Minoru Yoshiyama
    Heart and Vessels, 2021, 36 : 1784 - 1793
  • [46] Diagnostic Accuracy of Cardiac 64-Slice Computed Tomography in Detecting Atrial Thrombi Comparative Study With Transesophageal Echocardiography and Cardiac Surgery
    Feuchtner, Gudrun M.
    Dichtl, Wolfgang
    Bonatti, Johannes O.
    Jodocy, Daniel
    Mueller, Silvana
    Hintringer, Florian
    Gradl, Johannes
    Klauser, Andrea
    Cury, Ricardo C.
    INVESTIGATIVE RADIOLOGY, 2008, 43 (11) : 794 - 801
  • [47] Non-Contrast and Contrast-Enhanced Cardiac Computed Tomography Imaging in the Diagnostic and Prognostic Evaluation of Coronary Artery Disease
    Pugliese, Luca
    Ricci, Francesca
    Sica, Giacomo
    Scaglione, Mariano
    Masala, Salvatore
    DIAGNOSTICS, 2023, 13 (12)
  • [48] Prospective evaluation of the learning curve and diagnostic accuracy for Pre-TAVI cardiac computed tomography analysis by cardiologists in training: The LEARN-CT study
    Paolisso, Pasquale
    Gallinoro, Emanuele
    Andreini, Daniele
    Mileva, Niya
    Esposito, Giuseppe
    Bermpeis, Konstantinos
    Bertolone, Dario Tino
    Munhoz, Daniel
    Belmonte, Marta
    Fabbricatore, Davide
    Sonck, Jeroen
    Collet, Carlos
    Penicka, Martin
    De Bruyne, Bernard
    Vanderheyden, Marc
    Barbato, Emanuele
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2022, 16 (05) : 404 - 411
  • [49] Direct Comparison of Diagnostic Accuracy of Fast Kilovoltage Switching Dual-Energy Computed Tomography and Magnetic Resonance Imaging for Detection of Enhancement in Renal Masses
    McGrath, Trevor A.
    Ahmad, Faraz
    Sathiadoss, Paul
    Haroon, Mohammad
    McInnes, Matthew D. F.
    Bossuyt, Patrick M. M.
    Schieda, Nicola
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2022, 46 (06) : 862 - 870
  • [50] Cardiac computed tomography-derived epicardial fat volume and attenuation independently distinguish patients with and without myocardial infarction
    Mahabadi, Amir Abbas
    Balcer, Bastian
    Dykun, Iryna
    Forsting, Michael
    Schlosser, Thomas
    Heusch, Gerd
    Rassaf, Tienush
    PLOS ONE, 2017, 12 (08):