Diagnostic accuracy of late iodine enhancement on cardiac computed tomography with a denoise filter for the evaluation of myocardial infarction

被引:12
|
作者
Matsuda, Takuya [1 ]
Kido, Teruhito [1 ]
Itoh, Toshihide [2 ]
Saeki, Hideyuki [3 ]
Shigemi, Susumu [3 ]
Watanabe, Kouki [3 ]
Kido, Tomoyuki [4 ]
Aono, Shoji [4 ]
Yamamoto, Masaya [4 ]
Matsuda, Takeshi [5 ]
Mochizuki, Teruhito [1 ]
机构
[1] Ehime Univ, Grad Sch Med, Dept Radiol, Toon, Ehime 7910295, Japan
[2] Siemens Japan, Res & Collaborat, Shinagawa Ku, Tokyo, Japan
[3] Saiseikai Matsuyama Hosp, Dept Cardiol, Matsuyama, Ehime, Japan
[4] Saiseikai Matsuyama Hosp, Dept Radiol, Matsuyama, Ehime, Japan
[5] Matsuyama Red Cross Hosp, Dept Radiol, Matsuyama, Ehime, Japan
关键词
Acute myocardial infarction; Cardiac computed tomography; Image postprocessing; Late iodine enhancement; CORONARY-ANGIOGRAPHY; CT; PREDICTION; VIABILITY; MRI;
D O I
10.1007/s10554-015-0716-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We evaluated the image quality and diagnostic performance of late iodine enhancement (LIE) in dual-source computed tomography (DSCT) with low kilo-voltage peak (kVp) images and a denoise filter for the detection of acute myocardial infarction (AMI) in comparison with late gadolinium enhancement (LGE) magnetic resonance imaging (MRI). The Hospital Ethics Committee approved the study protocol. Before discharge, 19 patients who received percutaneous coronary intervention after AMI underwent DSCT and 1.5 T MRI. Immediately after coronary computed tomography (CT) angiography, contrast medium was administered at a slow injection rate. LIE-CT scans were acquired via dual-energy CT and reconstructed as 100-, 140-kVp, and mixed images. An iterative three-dimensional edge-preserved smoothing filter was applied to the 100-kVp images to obtain denoised 100-kVp images. The mixed, 140-kVp, 100-kVp, and denoised 100-kVp images were assessed using contrast-to-noise ratio (CNR), and their diagnostic performance in comparison with MRI and infarcted volumes were evaluated. Three hundred four segments of 19 patients were evaluated. Fifty-three segments showed LGE in MRI. The median CNR of the mixed, 140-, 100-kVp and denoised 100-kVp images was 3.49, 1.21, 3.57, and 6.08, respectively. The median CNR was significantly higher in the denoised 100-kVp images than in the other three images (P < 0.05). The denoised 100-kVp images showed the highest diagnostic accuracy and sensitivity. The percentage of myocardium in the four CT image types was significantly correlated with the respective MRI findings. The use of a denoise filter with a low-kVp image can improve CNR, sensitivity, and accuracy in LIE-CT.
引用
收藏
页码:177 / 185
页数:9
相关论文
共 50 条
  • [1] Diagnostic accuracy of late iodine enhancement on cardiac computed tomography with a denoise filter for the evaluation of myocardial infarction
    Takuya Matsuda
    Teruhito Kido
    Toshihide Itoh
    Hideyuki Saeki
    Susumu Shigemi
    Kouki Watanabe
    Tomoyuki Kido
    Shoji Aono
    Masaya Yamamoto
    Takeshi Matsuda
    Teruhito Mochizuki
    The International Journal of Cardiovascular Imaging, 2015, 31 : 177 - 185
  • [2] Late iodine enhancement computed tomography with image subtraction for assessment of myocardial infarction
    Tanabe, Yuki
    Kido, Teruhito
    Kurata, Akira
    Kouchi, Takanori
    Fukuyama, Naoki
    Yokoi, Takahiro
    Uetani, Teruyoshi
    Yamashita, Natsumi
    Miyagawa, Masao
    Mochizuki, Teruhito
    EUROPEAN RADIOLOGY, 2018, 28 (03) : 1285 - 1292
  • [3] Evaluation of monoenergetic late iodine enhancement dual-energy computed tomography for imaging of chronic myocardial infarction
    Wichmann, Julian L.
    Arbaciauskaite, Ruta
    Kerl, J. Matthias
    Frellesen, Claudia
    Bodelle, Boris
    Lehnert, Thomas
    Monsefi, Nadejda
    Vogl, Thomas J.
    Bauer, Ralf W.
    EUROPEAN RADIOLOGY, 2014, 24 (06) : 1211 - 1218
  • [4] Late iodine enhancement cardiac computed tomography for detection of myocardial scars: impact of experience in the clinical practice
    Palmisano, Anna
    Vignale, Davide
    Benedetti, Giulia
    Del Maschio, Alessandro
    De Cobelli, Francesco
    Esposito, Antonio
    RADIOLOGIA MEDICA, 2020, 125 (02): : 128 - 136
  • [5] Late iodine enhancement cardiac computed tomography for detection of myocardial scars: impact of experience in the clinical practice
    Anna Palmisano
    Davide Vignale
    Giulia Benedetti
    Alessandro Del Maschio
    Francesco De Cobelli
    Antonio Esposito
    La radiologia medica, 2020, 125 : 128 - 136
  • [6] Diagnostic accuracy of late iodine enhancement on cardiac CT for myocardial tissue characterization: a systematic review and meta-analysis
    Gatti, Marco
    De Filippo, Ovidio
    Cura, Gaia Cura
    Dusi, Veronica
    Di Vita, Umberto
    Gallone, Guglielmo
    Morena, Arianna
    Palmisano, Anna
    Pasinato, Elettra
    Solano, Andrea
    De Ferrari, Gaetano Maria
    Esposito, Antonio
    Fonio, Paolo
    Faletti, Riccardo
    D'Ascenzo, Fabrizio
    EUROPEAN RADIOLOGY, 2024, : 3054 - 3067
  • [7] Prognostic Value of Myocardial Contrast Delayed Enhancement With 64-Slice Multidetector Computed Tomography After Acute Myocardial Infarction
    Sato, Akira
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (08) : 731 - 738
  • [8] Impact of knowledge-based iterative model reconstruction on myocardial late iodine enhancement in computed tomography and comparison with cardiac magnetic resonance
    Yuki Tanabe
    Teruhito Kido
    Akira Kurata
    Naoki Fukuyama
    Takahiro Yokoi
    Tomoyuki Kido
    Teruyoshi Uetani
    Mani Vembar
    Amar Dhanantwari
    Shinichi Tokuyasu
    Natsumi Yamashita
    Teruhito Mochizuki
    The International Journal of Cardiovascular Imaging, 2017, 33 : 1609 - 1618
  • [9] Impact of knowledge-based iterative model reconstruction on myocardial late iodine enhancement in computed tomography and comparison with cardiac magnetic resonance
    Tanabe, Yuki
    Kido, Teruhito
    Kurata, Akira
    Fukuyama, Naoki
    Yokoi, Takahiro
    Kido, Tomoyuki
    Uetani, Teruyoshi
    Vembar, Mani
    Dhanantwari, Amar
    Tokuyasu, Shinichi
    Yamashita, Natsumi
    Mochizuki, Teruhito
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (10) : 1609 - 1618
  • [10] Assessment of myocardial delayed enhancement with cardiac computed tomography in cardiomyopathies: a prospective comparison with delayed enhancement cardiac magnetic resonance imaging
    Lee, Hye-Jeong
    Im, Dong Jin
    Youn, Jong-Chan
    Chang, Suyon
    Suh, Young Joo
    Hong, Yoo Jin
    Kim, Young Jin
    Hur, Jin
    Choi, Byoung Wook
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (04) : 577 - 584