High resolution frequency measurements of the 110 GHz gyrotron at TEXTOR and the 105 GHz mode of the two-frequency gyrotron (Odissey-1) at ASDEX Upgrade (AUG) have been made in support of fast ion collective Thomson scattering diagnostics. Measurements were done by harmonic heterodyne methods using both fast Fourier transform spectroscopy with digital oscilloscopes and fast scanning spectrum analyzers. Accurate frequencies were obtained with a frequency counter. At TEXTOR, at 180 kW forward power the starting frequency was 109.970 +/- 0.005 GHz and chirped down as much as 27 MHz depending on the duty factor. At AUG, at 500 kW forward power the frequency started at 104.786 GHz and chirped down 104 MHz, with 90% of the chirp occurring in the first 100 ms. Plasma perturbation of the TEXTOR gyrotron was observed when both ion cyclotron resonance heating antennas and neutral beam injection were operating, producing modulation at 29 and 58 MHz in the gyrotron output. Each gyrotron was observed to have an instrumental measurement limited linewidth of 120 kHz full width at half maximum. (c) 2006 American Institute of Physics.
引用
收藏
页数:4
相关论文
共 8 条
[1]   Response of a gyrotron to small-amplitude low-frequency-modulated microwaves reflected from a plasma [J].
Batanov, GM ;
Kolik, LV ;
Novozhilova, YV ;
Petelin, MI ;
Petrov, AE ;
Sarksyan, KA ;
Skvortsova, NN ;
Kharchev, NK .
TECHNICAL PHYSICS, 2001, 46 (05) :595-600
[2]   Fast ion collective Thomson scattering, JET results and TEXTOR plans [J].
Bindslev, H ;
Porte, L ;
Hoekzema, A ;
Machuzak, J ;
Woskov, P ;
Van Eester, D ;
Egedal, J ;
Fessey, J ;
Hughes, T .
FUSION ENGINEERING AND DESIGN, 2001, 53 (1-4) :105-111
[3]   Accurate frequency measurement of a submillimeter wave gyrotron output using a far-infrared laser as a reference [J].
Idehara, T ;
Mitsudo, S ;
Saito, S ;
Ogawa, I ;
Okajima, S .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (05) :2860-2862
[4]   FREQUENCY PULLING AND BANDWIDTH MEASUREMENTS OF A 140 GHZ PULSED GYROTRON [J].
KREISCHER, KE ;
DANLY, BG ;
WOSKOBOINIKOW, P ;
MULLIGAN, WJ ;
TEMKIN, RJ .
INTERNATIONAL JOURNAL OF ELECTRONICS, 1984, 57 (06) :851-862
[5]   Time-frequency analysis of modulation of high-power microwaves by electron-beam voltage fluctuations [J].
Peters, CW ;
Jaynes, RL ;
Lau, YY ;
Gilgenbach, RM ;
Williams, WJ ;
Hochman, JM ;
Cohen, WE ;
Rintamaki, JI ;
Vollers, DE ;
Spencer, TA .
PHYSICAL REVIEW E, 1998, 58 (05) :6880-6883
[6]  
PRINZ HO, 2005, P EURCON 2005 INT C, V2, P1871
[7]  
Wagner D, 2005, IRMMW-THz2005: The Joint 30th International Conference on Infrared and Millimeter Waves and 13th International Conference on Terahertz Electronics, Vols 1 and 2, P24
[8]   Electron cyclotron resonance heating on TEXTOR [J].
Westerhof, E ;
Hoekzema, IA ;
Hogeweij, GMD ;
Jaspers, RJE ;
Schüller, FC ;
Barth, CJ ;
Bindslev, H ;
Bongers, WA ;
Donné, AJH ;
Dumortier, P ;
Van der Grift, AF ;
Kalupin, D ;
Koslowski, HR ;
Krämer-Flecken, A ;
Kruijt, OG ;
Cardozo, NJL ;
Van der Meiden, HJ ;
Merkulov, A ;
Messiaen, A ;
Oosterbeek, JW ;
Prins, PR ;
Scholten, J ;
Udintsev, VS ;
Unterberg, B ;
Vervier, M ;
Van Wassenhove, G .
FUSION SCIENCE AND TECHNOLOGY, 2005, 47 (02) :108-118