A novel approach and protocol for discovering extremely low-abundance proteins in serum

被引:45
作者
Tanaka, Yoshinori
Akiyama, Hideo
Kuroda, Toshihiko
Jung, Giman
Tanahashi, Kazuhiro
Sugaya, Hiroyuki
Utsumi, Jun
Kawasaki, Hiroshi
Hirano, Hisashi
机构
[1] Toray Industries Ltd, New Frontiers Res Labs, Kamakura, Kanagawa 2488555, Japan
[2] Toray Industries Ltd, Specialty Mat Res Labs, Otsu, Shiga, Japan
[3] Toray Industries Ltd, Corp Res Dept, Tokyo, Japan
[4] Yokohama City Univ, Int Grad Sch Arts & Sci, Yokohama, Kanagawa 232, Japan
关键词
3-D-LC; hollow-fiber membrane; plasma; serum;
D O I
10.1002/pmic.200500774
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The proteomic analysis of serum (plasma) has been a major approach to determining biomarkers essential for early disease diagnoses and drug discoveries. The determination of these biomarkers, however, is analytically challenging since the dynamic concentration range of serum proteins/peptides is extremely wide (more than 10 orders of magnitude). Thus, the reduction in sample complexity prior to proteomic analyses is essential, particularly in analyzing low-abundance protein biomarkers. Here, we demonstrate a novel approach to the proteomic analyses of human serum that uses an originally developed serum protein separation device and a sequentially linked 3-D-LC-MS/MS system. Our hollow-fiber-membrane-based serum pretreatment device can efficiently deplete high-molecular weight proteins and concentrate low-molecular weight proteins/peptides automatically within 1 h. Four independent analyses of healthy human sera pretreated using this unique device, followed by the 3-D-LC-MS/MS successfully produced 12000-13000 MS/MS spectra and hit around 1800 proteins (> 95% reliability) and 2300 proteins (> 80% reliability). We believe that the unique serum pretreatment device and proteomic analysis protocol reported here could be a powerful tool for searching physiological biomarkers by its high throughput (3.7 days per one sample analysis) and high performance of finding low abundant proteins from serum or plasma samples.
引用
收藏
页码:4845 / 4855
页数:11
相关论文
共 43 条
[21]  
Lathrop JT, 2003, CURR OPIN MOL THER, V5, P250
[22]  
Lollo BA, 1999, ELECTROPHORESIS, V20, P854, DOI 10.1002/(SICI)1522-2683(19990101)20:4/5<854::AID-ELPS854>3.0.CO
[23]  
2-6
[24]   Evaluation of multidimensional chromatography coupled with tandem mass spectrometry (LC/LC-MS/MS) for large-scale protein analysis: The yeast proteome [J].
Peng, JM ;
Elias, JE ;
Thoreen, CC ;
Licklider, LJ ;
Gygi, SP .
JOURNAL OF PROTEOME RESEARCH, 2003, 2 (01) :43-50
[25]  
Perkins DN, 1999, ELECTROPHORESIS, V20, P3551, DOI 10.1002/(SICI)1522-2683(19991201)20:18<3551::AID-ELPS3551>3.0.CO
[26]  
2-2
[27]   Use of proteomic patterns in serum to identify ovarian cancer [J].
Petricoin, EF ;
Ardekani, AM ;
Hitt, BA ;
Levine, PJ ;
Fusaro, VA ;
Steinberg, SM ;
Mills, GB ;
Simone, C ;
Fishman, DA ;
Kohn, EC ;
Liotta, LA .
LANCET, 2002, 359 (9306) :572-577
[28]   The human serum proteome: Display of nearly 3700 chromatographically separated protein spots on two-dimensional electrophoresis gels and identification of 325 distinct proteins [J].
Pieper, R ;
Gatlin, CL ;
Makusky, AJ ;
Russo, PS ;
Schatz, CR ;
Miller, SS ;
Su, Q ;
McGrath, AM ;
Estock, MA ;
Parmar, PP ;
Zhao, M ;
Huang, ST ;
Zhou, J ;
Wang, F ;
Esquer-Blasco, R ;
Anderson, NL ;
Taylor, J ;
Steiner, S .
PROTEOMICS, 2003, 3 (07) :1345-1364
[29]   Liquid chromatography and electrospray mass spectrometric mapping of peptides from human plasma filtrate [J].
Raida, M ;
Schulz-Knappe, P ;
Heine, G ;
Forssmann, WG .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (01) :45-54
[30]   Serum proteomics in cancer diagnosis and management [J].
Rosenblatt, KP ;
Bryant-Greenwood, P ;
Killian, JK ;
Mehta, A ;
Geho, D ;
Espina, V ;
Petricoin, EE ;
Liotta, LA .
ANNUAL REVIEW OF MEDICINE, 2004, 55 :97-112