Ozone generation by indoor, electrostatic air cleaners

被引:140
|
作者
Boelter, KJ [1 ]
Davidson, JH [1 ]
机构
[1] UNIV MINNESOTA,DEPT MECH ENGN,PARTICLE TECHNOL LAB,MINNEAPOLIS,MN 55455
关键词
D O I
10.1080/02786829708965505
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This experimental study extends prior studies to consider the influences of discharge polarity, current, relative humidity, air temperature, and wire diameter and material on ozone generation rate in two-stage, wire-plate indoor air cleaners. Promising methods of decreasing the quantity of ozone released into living and work spaces are identified. Use of positive corona discharge is imperative since ozone generation rates are nearly an order of magnitude higher with negative discharge. For a specific precipitator design, the most important parameter in predicting ozone generation rate is current level. Changes in temperature and relative humidity of the inlet air stream over the range of ambient conditions expected in typical homes have less impact. In the commercial air cleaner studied, a 40% reduction in current from 1.08 to 0.60 mA, reduces ozone generation rate by nearly 50% from 0.005 to 0.0025 mg s(-1). This reduction in current reduces particle collection efficiency by 20%. An increase in relative humidity from 17 to 55% decreases ozone generation rate 17%. An increase in air temperature from 293 to 301K decreases ozone generation rate by 6%. Ozone production can be controlled by the selection of wire diameter and material. At a fixed voltage, use of 0.10 mm rather than 0.20 mm tungsten discharge wires reduces ozone generation rate by 40%. The accompanying reduction in current does not cause a reduction in collection efficiency as long as the voltage in the collection stage is held constant. The benefit of controlling ozone generation rate by selection of wire material is that the electrical characteristics of the air cleaner are not affected. With a positive corona discharge, ozone generation rate is decreased by 30% with copper wires and by 50% with silver wires as compared to the rate with standard tungsten wires. (C) 1997 American Association for Aerosol Research.
引用
收藏
页码:689 / 708
页数:20
相关论文
共 50 条
  • [1] Design of electrostatic air cleaners and use of filters to reduce indoor ozone
    Davidson, J
    Greden, L
    Lee, P
    ADVANCES IN FILTRATION AND SEPARATION TECHNOLOGY, VOLS 13A AND 13B, 1999: ADVANCING FILTRATION AND SEPARATION SOLUTIONS FOR THE MILLENNIUM, 1999, : 695 - 702
  • [2] Long-term ozone generation from electrostatic air cleaners
    Tanasomwang, L
    Lai, FC
    IAS '97 - CONFERENCE RECORD OF THE 1997 IEEE INDUSTRY APPLICATIONS CONFERENCE / THIRTY-SECOND IAS ANNUAL MEETING, VOLS 1-3, 1997, : 2037 - 2044
  • [3] OZONE PRODUCTION IN ELECTROSTATIC AIR CLEANERS WITH CONTAMINATED ELECTRODES
    DORSEY, JA
    DAVIDSON, JH
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1994, 30 (02) : 370 - 376
  • [4] Evaluation of ozone generation and indoor organic compounds removal by air cleaners based on chamber tests
    Yu, Kuo-Pin
    Lee, Grace Whei-May
    Hsieh, Ching-Pei
    Lin, Chi-Chi
    ATMOSPHERIC ENVIRONMENT, 2011, 45 (01) : 35 - 42
  • [5] Using ozone air cleaners to remove indoor volatile organic compounds
    Yu, KP
    Lee, GWM
    Hsieh, CP
    Yang, SH
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 2981 - 2985
  • [6] ELECTRONIC AIR CLEANERS AND OZONE
    SIEDLECK.JT
    JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1970, 213 (06): : 1044 - &
  • [7] Indoor Plants as Air Cleaners
    Dela Cruz, M.
    Christensen, J. H.
    Mueller, R.
    XI INTERNATIONAL PEOPLE PLANT SYMPOSIUM ON DIVERSITY: TOWARDS A NEW VISION OF NATURE, 2015, 1093 : 133 - 137
  • [8] The Assessment of Indoor Formaldehyde and Bioaerosol Removal by Using Negative Discharge Electrostatic Air Cleaners
    Liu, Chao-Yun
    Tseng, Chao-Heng
    Wang, Kai-Feng
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (12)
  • [9] AIR CLEANERS AND INDOOR AIR-QUALITY
    SPARKS, LE
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1988, 30 (07): : 45 - 45
  • [10] Role of particulate air cleaners in indoor air quality
    Ensor, D.S.
    Hanley, J.T.
    Smith, D.D.
    Lawless, P.A.
    Owen, M.K.
    Sparks, L.E.
    Proceedings of the International Aerosol Conference, 1990,