Comparative Enantiomer-Resolving Ability of Coated and Covalently Immobilized Versions of Two Polysaccharide-Based Chiral Selectors in High-Performance Liquid Chromatography

被引:20
|
作者
Beridze, Nino [1 ]
Tsutskiridze, Eka [1 ]
Takaishvili, Nino [1 ]
Farkas, Tivadar [2 ]
Chankvetadze, Bezhan [1 ]
机构
[1] Tbilisi State Univ, Inst Phys & Analyt Chem, Sch Exact & Nat Sci, Chavchavadze Ave 3, GE-0179 Tbilisi, Georgia
[2] Phenomenex Inc, 411 Madrid Ave, Torrance, CA 90501 USA
基金
美国国家科学基金会;
关键词
Separation of enantiomers; Coated vs. covalently immobilized polysaccharide-based chiral columns; Chiral drugs; NONAQUEOUS CAPILLARY ELECTROCHROMATOGRAPHY; STATIONARY PHASES; CELLULOSE TRIS(3,5-DICHLOROPHENYLCARBAMATE); ENANTIOSEPARATION; DERIVATIVES; SEPARATION; COLUMNS; TRIS(3,5-DIMETHYLPHENYLCARBAMATE); HPLC; SULFOXIDES;
D O I
10.1007/s10337-018-3493-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The separation of enantiomers of over 175 randomly selected chiral acidic, basic, and neutral compounds was studied on 4 polysaccharide-based chiral columns made by coating or covalent attachment of cellulose 3,5-dichlorophenylcarbamate or amylose 3,5-dimethylphenylcarbamate on the surface of silica. Triscarbamate derivatives of cellulose or amylose were used for the preparation of coated-type columns, while in the case of covalently immobilized chiral stationary phases, the respective polysaccharides were not completely carbamoylated but only close to triscarbamates. It was found that this minimal difference in the chemical composition of the polysaccharide derivatives resulted in significantly different enantiomer-resolving ability for certain groups of chiral compounds while only marginally different for other chiral analytes. This potential difference between coated- and covalently immobilized versions of the "same" chiral selector must be considered in method development with these columns, as well as in method transfer between them.
引用
收藏
页码:611 / 621
页数:11
相关论文
共 50 条
  • [21] Chromatographic and thermodynamic comparison of amylose tris(3-chloro-5-methylphenylcarbamate) coated or covalently immobilized on silica in high-performance liquid chromatographic separation of the enantiomers of select chiral weak acids
    Maisuradze, Mariam
    Sheklashvili, Gvantsa
    Chokheli, Ana
    Matarashvili, Iza
    Gogatishvili, Teona
    Farkas, Tivadar
    Chankvetadze, Bezhan
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1602 : 228 - 236
  • [22] Recent trends in preparation, investigation and application of polysaccharide-based chiral stationary phases for separation of enantiomers in high-performance liquid chromatography
    Chankvetadze, Bezhan
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2020, 122
  • [23] Enantioseparation and study of thermodynamical property of metalaxyl on a polysaccharide-based chiral column by high performance liquid chromatography
    Hou, JG
    Meng, XR
    He, TX
    Deng, HL
    Mao, XF
    Han, XQ
    Gao, JZ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 31 (03) : 307 - 310
  • [24] Effect of pore-size optimization on the performance of polysaccharide-based superficially porous chiral stationary phases for the separation of enantiomers in high-performance liquid chromatography
    Bezhitashvili, Lia
    Bardavelidze, Anna
    Ordjonikidze, Teona
    Chankvetadze, Lali
    Chity, Mike
    Farkas, Tivadar
    Chankvetadze, Bezhan
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1482 : 32 - 38
  • [25] High-performance liquid chromatographic enantioseparation of unusual amino acid derivatives with axial chirality on polysaccharide-based chiral stationary phases
    Lopez-Ram-de-Viu, Pilar
    Galvez, Jose A.
    Diaz-de-Villegas, Maria D.
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1390 : 78 - 85
  • [26] Enantioseparation of pyroglutamide derivatives on polysaccharide based chiral stationary phases by high-performance liquid chromatography and supercritical fluid chromatography: A comparative study
    Baudelet, Davy
    Schifano-Faux, Nadege
    Ghinet, Alina
    Dezitter, Xavier
    Barbotin, Florent
    Gautret, Philippe
    Rigo, Benoit
    Chavatte, Philippe
    Millet, Regis
    Furman, Christophe
    Vaccher, Claude
    Lipka, Emmanuelle
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1363 : 257 - 269
  • [27] Temperature and eluent composition effects on enantiomer separation of carvedilol by high-performance liquid chromatography on immobilized amylose-based chiral stationary phases
    Panella, Cristina
    Ferretti, Rosella
    Casulli, Adriano
    Cirilli, Roberto
    JOURNAL OF PHARMACEUTICAL ANALYSIS, 2019, 9 (05) : 324 - 331
  • [28] Use of polysaccharide-based chiral columns: enantiomeric separation of seven pairs of abused drugs by high-performance liquid chromatography-mass spectrometry
    Karatt, Tajudheen K.
    Kal, Abdul Khader Karakka
    Sayed, Ramy
    Nalakath, Jahfar
    Perwad, Zubair
    FORENSIC TOXICOLOGY, 2019, 37 (01) : 254 - 260
  • [29] High-performance liquid chromatography enantioseparation of polyhalogenated 4,4′-bipyridines on polysaccharide-based chiral stationary phases under multimodal elution
    Peluso, Paola
    Mamane, Victor
    Aubert, Emmanuel
    Cossu, Sergio
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (18) : 2481 - 2489
  • [30] Separation of enantiomers of chiral weak acids with polysaccharide-based chiral columns and aqueous-organic mobile phases in high-performance liquid chromatography: Typical reversed-phase behavior?
    Matarashvili, Iza
    Ghughunishvili, Darejan
    Chankvetadze, Lali
    Takaishvili, Nino
    Khatiashvili, Tamar
    Tsintsadze, Maia
    Farkas, Tivadar
    Chankvetadze, Bezhan
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1483 : 86 - 92