Volumetric Blood Flow Measurement in the Ophthalmic Artery Using Colour Doppler

被引:6
作者
Katamay, R. [1 ]
Fleischlin, C. [1 ]
Gugleta, K. [1 ]
Flammer, J. [1 ]
Orguel, S. [1 ]
机构
[1] Univ Eye Clin, Basel, Switzerland
关键词
ophthalmic artery; volumetric blood flow; ultrasound; colour Doppler imaging; cardiac cycle; velocity; vessel diameter; cross-sectional area; PRESSURE MEASUREMENT; FINAPRES;
D O I
10.1055/s-0028-1109304
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: Herewith we present a new method for measurement of the volumetric blood flow in absolute units in the ophthalmic artery. Patients and Methods: A Philips EnVisor HD ultrasound unit with a 12 - 3 MHz linear transducer was used to measure flow in the ophthalmic artery in 8 healthy young subjects. The transducer was mounted on a custom-made holder which enabled precise and reproducible positioning in 3 axes as well as in rotation angle. Blood flow velocity and vessel diameter were measured during 10 consecutive heartbeats. The measurements were ECG-gated. Blood vessel diameter and blood flow velocity were calculated in an average heartbeat cycle. Hence blood volume over time within a heartbeat cycle as well as blood flow in mL/min were determined. Simultaneously, cardiovascular parameters have been recorded by Finapres. Short time reproducibility (5 measurements on day 1) and long time reproducibility (5 days once daily) as well as interindividual coefficient of variation were evaluated. Results: Average blood flow in the ophthalmic artery in all measurements was 39.7 mL/min. The short-term intraindividual coefficient of variation was 24.1 +/- 9.2%, the long-term coefficient 32.0 +/- 13.8%. Interindividual coefficient of variation was 32.8%. Conclusions: Our method allows volumetric blood flow measurements in the ophthalmic artery in absolute units, reproducible to a limited extent.
引用
收藏
页码:249 / 253
页数:5
相关论文
共 12 条
[1]   COLOR-CODED CAROTID DOPPLER IMAGING - AN ANGIOGRAPHIC COMPARISON OF 324 BIFURCATIONS [J].
ACKROYD, N ;
LANE, R ;
DART, L ;
APPLEBERG, M .
AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1984, 54 (06) :509-517
[2]   Volume flow rate evaluation in patients with obstructive arteriosclerotic disease [J].
Doberenz, C ;
Paulus, W ;
Reimers, CD ;
Eicke, BM .
CEREBROVASCULAR DISEASES, 2004, 18 (04) :312-317
[3]   Accurate course and relationships of the intraorbital part of the ophthalmic artery in the sagittal plane [J].
Erdogmus, S. ;
Govsa, F. .
MINIMALLY INVASIVE NEUROSURGERY, 2007, 50 (04) :202-208
[4]   Volume flow estimation by colour duplex [J].
Licht, PB ;
Christensen, HW ;
Roder, O ;
Hoilund-Carlsen, PF .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1999, 17 (03) :219-224
[5]  
Michelson G, 1991, Fortschr Ophthalmol, V88, P687
[6]   CLINICAL-APPLICATIONS OF A NEW TYPE OF REAL-TIME TWO-DIMENSIONAL DOPPLER FLOW IMAGING-SYSTEM [J].
MIYATAKE, K ;
OKAMOTO, M ;
KINOSHITA, N ;
IZUMI, S ;
OWA, M ;
TAKAO, S ;
SAKAKIBARA, H ;
NIMURA, Y .
AMERICAN JOURNAL OF CARDIOLOGY, 1984, 54 (07) :857-868
[7]   RESOLUTION OF ULTRASOUND PULSED DOPPLER FOR BLOOD VELOCITY-MEASUREMENTS [J].
MORRIS, RL ;
HISTAND, MB ;
MILLER, CW .
JOURNAL OF BIOMECHANICS, 1973, 6 (06) :701-&
[8]   The first technique for non-invasive measurements of volumetric ophthalmic artery blood flow in humans [J].
Orge, F ;
Harris, A ;
Kagemann, L ;
Kopecky, K ;
Sheets, CW ;
Rechtman, E ;
Zalish, M .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2002, 86 (11) :1216-1219
[9]   RI in central retinal artery as assessed by CDI does not correspond to retinal vascular resistance [J].
Polska, E ;
Kircher, K ;
Ehrlich, P ;
Vecsei, PV ;
Schmetterer, L .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2001, 280 (04) :H1442-H1447
[10]   REGULATION OF VASCULAR TONE [J].
ROSSITTI, S ;
FRANGOS, J ;
GIRARD, PR ;
BEVAN, J .
CANADIAN JOURNAL OF PHYSIOLOGY AND PHARMACOLOGY, 1995, 73 (05) :544-550