Effect of signal intensity normalization on the multivariate analysis of spectral data in complex 'real-world' datasets

被引:28
作者
Beattie, J. Renwick [1 ]
Glenn, Josephine V. [1 ]
Boulton, Michael E. [2 ]
Stitt, Alan W. [1 ]
McGarvey, John J. [3 ]
机构
[1] Queens Univ Belfast, Inst Clin Sci, Ctr Vis Sci, Belfast BT12 6BJ, Antrim, North Ireland
[2] Univ Florida, Gainesville, FL USA
[3] Queens Univ Belfast, Sch Chem & Chem Engn, Belfast BT12 6BJ, Antrim, North Ireland
基金
英国生物技术与生命科学研究理事会;
关键词
intensity normalization; intensity standardization; Raman spectroscopy; vibrational spectroscopy; Bruch's membrane; RAMAN-SPECTROSCOPY; EXCITATION WAVELENGTH; AREA CENTRALIS; MICROSCOPY; PREDICTION; ACID;
D O I
10.1002/jrs.2146
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Spectral signal intensities, especially in 'real-world' applications with nonstandardized sample presentation due to uncontrolled variables/factors, commonly require additional spectral processing to normalize signal intensity in an effective way. In this study, we have demonstrated the complexity of choosing a normalization routine in the presence of multiple spectrally distinct constituents by probing a dataset of Raman spectra. Variation in absolute signal intensity (90.1% of total variance) of the Raman spectra of these complex biological samples swamps the variation in useful signals (9.4% of total variance), degrading its diagnostic and evaluative potential. Using traditional spectral band choices, it is shown that normalization results are more complex than generally encountered in traditionally designed sample sets investigating limited chemical species. We demonstrate that no choice of a single band proves to be appropriate for predicting all the reference parameters, instead requiring a tailored normalization routine for each parameter. Of the reference parameters studied in the chosen system, signals from pathogenic adducts in ocular tissues called advanced glycation endproducts were most prominent when normalizing about the 1550-1690 cm(-1) region of the spectrum (17.5% of total variance, compared with 0.3% for unnormalized), while prediction of pentosidine and gender were optimized by normalization about the 1570 (R(2) = 0.97 vs 0.57 for unnormalized) and 1003 cm-1 (p < 0.0000001 vs p < 0.01 for unnormalized) bands, respectively. The data obtained point to the extreme sensitivity of multivariate analysis to signal intensity normalization. Some general guidelines for making appropriate band choices are given, including the use of peak-finding routines. Copyright (C) 2008 John Wiley & Sons, Ltd.
引用
收藏
页码:429 / 435
页数:7
相关论文
共 17 条
[1]  
[Anonymous], 2005, Raman spectroscopy for chemical analysis M
[2]  
[Anonymous], 2001, NEAR INFRARED TECHNO
[3]  
Beattie JR, 2007, MOL VIS, V13, P1106
[4]   The use of Raman microscopy to determine and localize vitamin E in biological samples [J].
Beattie, J. Renwick ;
Maguire, Ciaran ;
Gilchrist, Sarah ;
Barrett, Lindsay J. ;
Cross, Carroll E. ;
Possmayer, Fred ;
Ennis, Madeleine ;
Elborn, J. Stuart ;
Curry, W. James ;
McGarvey, John J. ;
Schock, Bettina C. .
FASEB JOURNAL, 2007, 21 (03) :766-776
[5]  
Beattie JR, 2005, MOL VIS, V11, P825
[6]   Multivariate prediction of clarified butter composition using Raman spectroscopy [J].
Beattie, JR ;
Bell, SEJ ;
Borgaard, C ;
Fearon, AM ;
Moss, BW .
LIPIDS, 2004, 39 (09) :897-906
[7]   A critical evaluation of Raman spectroscopy for the analysis of lipids: Fatty acid methyl esters [J].
Beattie, JR ;
Bell, SEJ ;
Moss, BW .
LIPIDS, 2004, 39 (05) :407-419
[8]   Raman microspectroscopy of human coronary atherosclerosis: Biochemical assessment of cellular and extracellular morphologic structures in situ [J].
Buschman, HP ;
Deinum, G ;
Motz, JT ;
Fitzmaurice, M ;
Kramer, JR ;
van der Laarse, A ;
Bruschke, AV ;
Feld, MS .
CARDIOVASCULAR PATHOLOGY, 2001, 10 (02) :69-82
[9]   AMINO-ACIDS AND PROTEINS IN HAEMOGLOBIN FORMATION .2. ISOLEUCINE [J].
CHANDRAN, K ;
DAMODARAN, M .
BIOCHEMICAL JOURNAL, 1951, 49 (03) :393-398
[10]   Relative intensity correction of Raman spectrometers: NIST SRMs 2241 through 2243 for 785 nm, 532 nm, and 488 nm/514.5 nm excitation [J].
Choquette, Steven J. ;
Etz, Edgar S. ;
Hurst, Wilbur S. ;
Blackburn, Douglas H. ;
Leigh, Stefan D. .
APPLIED SPECTROSCOPY, 2007, 61 (02) :117-129