Absorbable screw fixation in anterior cruciate ligament reconstruction. A clinical, MRI and CT evaluation

被引:0
作者
Panni, AS
Milano, G
Masciocchi, C
Tartarone, M
Astolfi, S
机构
[1] Catholic Univ Rome, Ist Ortoped, I-00168 Rome, Italy
[2] Univ Sassari, Ist Ortoped, I-07100 Sassari, Italy
[3] Univ Aquila, Ist Radiol, I-67100 Laquila, Italy
来源
JOURNAL OF SPORTS TRAUMATOLOGY AND RELATED RESEARCH | 1999年 / 21卷 / 02期
关键词
anterior cruciate ligament; patellar tendon; interference screw; absorbable; polylactic acid;
D O I
暂无
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Absorbable (poly 1-lactic acid) interference screws were used to fix an autologous patellar tendon graft in 21 anterior cruciate ligament reconstructions. The results were evaluated clinically with the IKDC form and a KT 1000 arthrometer. CT and MRI were also carried out 3, 6 and 12 months after surgery. At follow-up after two years, the subjective assessments were normal in 5 cases, nearly normal in 12 and abnormal in 4. No cases of infection nor clinically evident reactive synovitis were observed. CT after 1 year showed that the bone plugs were completely incorporated in the bone tunnels. The gap between the screw and the plug was completely filled with bone and there was a reactive bone layer around the screw. There was no evidence of lysis at the absorbable implant site. The screws had retained their shape and there were slight signs of resorption along their outer and inner surfaces. MRI provided a more meaningful picture of the position of the tunnels and the intra-articular part of the graft. CT, on the other hand proved superior through its better demonstration of bone plug incorporation, the bone-screw interface and screw absorption.
引用
收藏
页码:89 / 100
页数:12
相关论文
共 27 条
[1]   THE STRENGTH OF ARTIFICIAL LIGAMENT ANCHORAGES - A COMPARATIVE EXPERIMENTAL-STUDY [J].
AMIS, AA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (03) :397-403
[2]  
BACH BR, 1989, AM J KNEE SURG, V2, P76
[3]   PRELIMINARY-RESULTS OF AN ABSORBABLE INTERFERENCE SCREW [J].
BARBER, FA ;
ELROD, BF ;
MCGUIRE, DA ;
PAULOS, LE .
ARTHROSCOPY, 1995, 11 (05) :537-548
[4]  
BARFOD G, 1992, ACTA ORTHOP SCAND, V63, P680
[5]   ABSORBABLE IMPLANTS FOR THE FIXATION OF FRACTURES [J].
BOSTMAN, OM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (01) :148-153
[6]   THE BIOMECHANICS OF INTERFERENCE SCREW FIXATION OF PATELLAR TENDON ANTERIOR CRUCIATE LIGAMENT GRAFTS [J].
BROWN, CH ;
HECKER, AT ;
HIPP, JA ;
MYERS, ER ;
HAYES, WC .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1993, 21 (06) :880-886
[7]   Biomechanical comparison between BioScrew and titanium alloy interference screws for bone-patellar tendon-bone graft fixation in anterior cruciate ligament reconstruction [J].
Caborn, DNM ;
Urban, WP ;
Johnson, DL ;
Nyland, J ;
Pienkowski, D .
ARTHROSCOPY, 1997, 13 (02) :229-232
[8]   THE STRENGTH OF THE CENTRAL 3RD PATELLAR TENDON GRAFT - A BIOMECHANICAL STUDY [J].
COOPER, DE ;
DENG, XHH ;
BURSTEIN, AL ;
WARREN, RF .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1993, 21 (06) :818-824
[9]   KNEE MECHANICS AFTER REPAIR OF THE ANTERIOR CRUCIATE LIGAMENT - A CADAVER STUDY OF LIGAMENT AUGMENTATION [J].
ENGEBRETSEN, L ;
LEW, WD ;
LEWIS, JL ;
HUNTER, RE .
ACTA ORTHOPAEDICA SCANDINAVICA, 1989, 60 (06) :703-709
[10]   INTRAARTICULAR PLACEMENT OF KUROSAKA INTERFERENCE SCREWS [J].
FRANCO, MG ;
BACH, BR ;
BUSHJOSEPH, CA .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 1994, 10 (04) :412-417