Evaluation of an automated method for measuring von Willebrand factor activity in clinical samples without ristocetin

被引:35
|
作者
Graf, L. [1 ]
Moffat, K. A. [2 ,3 ]
Carlino, S. A. [3 ]
Chan, A. K. C. [4 ]
Iorio, A. [5 ]
Giulivi, A. [6 ,7 ]
Hayward, C. P. M. [1 ,2 ]
机构
[1] McMaster Univ, Dept Pathol & Mol Med, Hamilton, ON L8S 4K1, Canada
[2] McMaster Univ, Dept Med, Hamilton, ON L8S 4K1, Canada
[3] Hamilton Reg Lab Med Program, Hamilton, ON, Canada
[4] McMaster Univ, Dept Pediat, Hamilton, ON L8S 4K1, Canada
[5] McMaster Univ, Dept Clin Epidemiol & Biostat, Hamilton, ON L8S 4K1, Canada
[6] Univ Ottawa, Dept Pathol & Lab Med, Ottawa, ON, Canada
[7] Ottawa Hosp, Ottawa, ON, Canada
关键词
diagnostic testing; von Willebrand factor; von Willebrand disease; von Willebrand factor activity; COFACTOR ACTIVITY; LABORATORY DIAGNOSIS; DISEASE; ASSAY; CLASSIFICATION; PATHOPHYSIOLOGY; RELIABILITY; MUTATIONS; BINDING; UPDATE;
D O I
10.1111/ijlh.12218
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction The development of an automated, von Willebrand factor (VWF) activity assay, Innovance((R)) VWF Ac (VWF:Ac), which measures VWF binding to the platelet receptor glycoprotein Ib alpha without ristocetin, led us to evaluate the assay for diagnosing von Willebrand disease (VWD) and monitoring therapy. Methods After validating that the assay could be performed on an instrument from a different manufacturer, we compared VWF:Ac to VWF ristocetin cofactor activity (VWF:RCo) findings, including ratios of activity/antigen, for 100 healthy controls and 262 consecutive clinical samples from 217 patients (197 adults, 64 children, n=1 age unknown) referred for VWF testing. Results There was excellent correlation (R-2=0.96) between VWF:Ac results run at two different sites on two different instruments. VWF:Ac had greater precision and sensitivity to low levels of VWF than the VWF:RCo method. Although there was good correlation between VWF:Ac and VWF:RCo results among healthy controls and patient subjects, VWF:Ac results were undetectable and/or significantly lower than VWF:RCo among patients who had types 2A, 2B, or 2M VWD. Additionally, a higher proportion of patient samples were classified as showing qualitative defects using the VWF:Ac compared with VWF:RCo method. While most samples drawn on VWD therapy had similar VWF levels by VWF:Ac and VWF:RCo, a type 2B VWD subject on replacement had much lower activity estimated by VWF:Ac. Conclusion We conclude that Innovance((R)) VWF Ac is suitable for the diagnosis, classification, and monitoring of VWD, and that it has a number of advantages over VWF:RCo method.
引用
收藏
页码:341 / 351
页数:11
相关论文
共 50 条
  • [1] Evaluation of an automated von Willebrand factor activity assay without ristocetin
    Sfaxi, Amine
    Borgi, Wijden
    Ben Lakhal, Fatma
    Selem, Sarra Fekih
    Gouider, Emna
    HAEMOPHILIA, 2022, 28 : 93 - 93
  • [2] A COMPARATIVE EVALUATION OF AUTOMATED VON WILLEBRAND FACTOR ACTIVITY ASSAYS WITH AND WITHOUT RISTOCETIN
    Belhadj, M.
    El Borgi, W.
    Ben Lakhal, F.
    Salem, S. Fekih
    Gouider, E.
    HAEMOPHILIA, 2020, 26 : 34 - 34
  • [3] Evaluation of an automated method for the measurement of Ristocetin cofactor activity of von Willebrand factor (VWF:RCo)
    Fortune, H.
    Rafferty, M.
    O'Connell, N.
    O'Donnell, J.
    Byrne, M.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2011, 9 : 919 - 920
  • [4] A comparative evaluation of two new automated assays for von Willebrand factor ristocetin cofactor activity and von Willebrand factor antigen
    Stufano, F.
    Lawrie, A. S.
    La Marca, S.
    Canciani, M. T.
    Franchi, F.
    Cozzi, G.
    Baronciani, L.
    Peyvandi, F.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2013, 11 : 682 - 682
  • [5] Evaluation of two automated methods for measurement of the ristocetin cofactor activity of von Willebrand factor
    Miller, CH
    Platt, SJ
    Daniele, C
    Kaczor, D
    THROMBOSIS AND HAEMOSTASIS, 2002, 88 (01) : 56 - 59
  • [6] Validation of an automated assay to determine activity of ristocetin cofactor of von Willebrand factor
    Duboscq, Cristina
    Martinuzzo, Marta
    Manuel Ceresetto, Juan
    Carlos Otaso, Juan
    Barrera, Luis
    Maria Oyhamburu, Jose
    Stemmelin, German
    ACTA BIOQUIMICA CLINICA LATINOAMERICANA, 2016, 50 (02):
  • [7] A new automated chemiluminescent method for the determination of von Willebrand factor ristocetin cofactor activity (VWF:RCO) and von willebrand factor antigen (VWF:AG)
    Friedman, K. D.
    Jacobi, P. M.
    Shaw, M. E.
    Endres, J. L.
    Haberichter, S. L.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2013, 11 : 98 - 99
  • [8] Evaluation of a rapid automated assay for analysis of von Willebrand ristocetin cofactor activity
    Strandberg, K
    Lethagen, S
    Andersson, K
    Carlson, A
    Hillarp, A
    CLINICAL AND APPLIED THROMBOSIS-HEMOSTASIS, 2006, 12 (01) : 61 - 67
  • [9] Comparison of a new automated von Willebrand factor activity assay with an aggregation von Willebrand ristocetin cofactor activity assay for the diagnosis of von Willebrand disease
    De Vleeschamer, An
    Devreese, Katrien
    BLOOD COAGULATION & FIBRINOLYSIS, 2006, 17 (05) : 353 - 358
  • [10] Evaluation of an Automated von Willebrand Factor Activity Assay in von Willebrand Disease
    Trossaert, Marc
    Ternisien, Catherine
    Lefrancois, Armelle
    Llopis, Laura
    Goudemand, Jenny
    Sigaud, Marianne
    Fouassier, Marc
    Caron, Claudine
    CLINICAL AND APPLIED THROMBOSIS-HEMOSTASIS, 2011, 17 (06) : E25 - E29