Skull Conductivity Estimation for EEG Source Localization

被引:3
|
作者
Costa, Facundo [1 ]
Batatia, Hadj [1 ]
Oberlin, Thomas [1 ]
Tourneret, Jean-Yves [1 ]
机构
[1] Univ Toulouse, INP ENSEEIHT, F-31071 Toulouse, France
关键词
Bayes methods; M/EEG measurements; source localization; sparsity; IN-VIVO; TISSUE CONDUCTIVITY; MODEL ERRORS; MEG; HEAD; BRAIN;
D O I
10.1109/LSP.2017.2669101
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Areliable leadfield matrix is needed to solve the magnetoencephalography/electroencephalography (M/EEG) source localization problem. The computation of this matrix requires several physical parameters, including the conductivity of the tissues that compose the subject's head. Since it is not precisely known, we modify a recent Bayesian algorithm to estimate the skull conductivity jointly with the brain activity directly from the M/EEG measurements. Synthetic and real data are used to compare our technique with two optimization algorithms, showing that the proposed method is able to provide results of similar or better quality with the advantage of being applicable in a more general case.
引用
收藏
页码:422 / 426
页数:5
相关论文
共 50 条
  • [21] MSP Based Source Localization Using EEG Signals
    Jatoi, Munsif Ali
    Kamel, Nidal
    David Lopez, Jose
    Faye, Ibrahima
    Malik, Aamir Saeed
    2016 6TH INTERNATIONAL CONFERENCE ON INTELLIGENT AND ADVANCED SYSTEMS (ICIAS), 2016,
  • [22] Inverse Problem for M/EEG Source Localization: A Review
    Basri, Seyed Masoud Moosavi
    Al-Nashash, Hasan
    Mir, Hasan
    IEEE SENSORS JOURNAL, 2025, 25 (02) : 2103 - 2124
  • [23] Estimation of the electric conductivity from scalp measurements: feasibility and application to source localization
    van Burik, MJ
    Peters, MJ
    CLINICAL NEUROPHYSIOLOGY, 2000, 111 (08) : 1514 - 1521
  • [24] Global sensitivity of EEG source analysis to tissue conductivity uncertainties
    Vorwerk, Johannes
    Wolters, Carsten H.
    Baumgarten, Daniel
    FRONTIERS IN HUMAN NEUROSCIENCE, 2024, 18
  • [25] Sparse algorithms for EEG source localization
    Teja Mannepalli
    Aurobinda Routray
    Medical & Biological Engineering & Computing, 2021, 59 : 2325 - 2352
  • [26] Truncated RAP-MUSIC (TRAP-MUSIC) for MEG and EEG source localization
    Makela, Niko
    Stenroos, Matti
    Sarvas, Jukka
    Ilmoniemi, Risto J.
    NEUROIMAGE, 2018, 167 : 73 - 83
  • [27] Transfer-Function-Based Calibration of Sparse EEG Systems for Brain Source Localization
    Zarghami, Tahereh
    Mir, Hasan S.
    Al-Nashash, Hasan
    IEEE SENSORS JOURNAL, 2015, 15 (03) : 1504 - 1514
  • [28] DYNAMO: Concurrent dynamic multi-model source localization method for EEG and/or MEG
    Antelis, Javier M.
    Minguez, Javier
    JOURNAL OF NEUROSCIENCE METHODS, 2013, 212 (01) : 28 - 42
  • [29] Anisotropic Conductivity of Rat Head Phantom and Its Influence on Electroencephalogram Source Localization
    Lacik, Jaroslav
    Koudelka, Vlastimil
    Vejmola, Cestmir
    Kuratko, David
    Vanek, Jiri
    Wojcik, Daniel Krzysztof
    Palenicek, Tomas
    Raida, Zbynek
    IEEE ACCESS, 2022, 10 : 9877 - 9888
  • [30] MEG and EEG source localization in beamspace
    Rodríguez-Rivera, A
    Baryshnikov, BV
    Van Veen, BD
    Wakai, RT
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (03) : 430 - 441