A comparison between LP(GMA) and CLP(GMA) polymer composites as an immobilization matrix for biosensing applications: A model immunosensor for IL 1α

被引:8
作者
Aydin, Elif Burcu [1 ]
Sezginturk, Mustafa Kemal [2 ]
机构
[1] Tekirdag Namik Kemal Univ, Sci & Technol Res Ctr, Tekirdag, Turkey
[2] Canakkale Onsekiz Mart Univ, Fac Engn, Bioengn Dept, Canakkale, Turkey
关键词
Disposable ITO electrode; Interleukin; 1; alpha; poly(glycidyl methacrylate) polymer; Electrochemical impedance spectroscopy; CARBON-BLACK; KINETIC-ANALYSIS; ELECTRODE; SERUM; INTERLEUKIN-1-ALPHA; NANOCOMPOSITE; FABRICATION; APTASENSOR; BIOMARKERS; SALIVA;
D O I
10.1016/j.aca.2019.05.049
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A comparative study was made by using two matrices (Linear poly(glycidyl methacrylate) (GMA) polymer (LP(GMA)) and carbon black-polyvinylidene fluoride (PVDF)-LP(GMA) composite CLP(GMA)) as immobilization platforms for anti-IL 1 alpha antibody on the development of impedimetric immunosensor for IL 1 alpha biomarker determination. These materials were spin coated onto the clean ITO electrode surface separately and used for IL 1 alpha immunosensor fabrication. Carbon black is utilized as a conductive material and has been employed over the last few decades for electrochemical biosensors development. The using of CLP(GMA) composite as an interface material shows fast electron transfer, when compared to LP(GMA) modified ITO electrode. This comparative study investigated the efficacy of carbon black for impedimetric biosensing. Anti-IL 1 alpha antibodies were utilized as bioreceptors and bound to epoxy groups of GMA polymer. For electrochemical characterizations, Electrochemical Impedance Spectroscopy, Cyclic Voltammetry and Single Frequency Impedance methods were employed. Furthermore, to follow the antibody attachment on the modified ITO substrates, Fourier Transform Infrared Spectroscopy and Raman spectral techniques were utilized. The morphological characterizations of immunosensor construction stages were carried out by Scanning Electron Microscopy and Atomic Force Microscopy analyses. The sensitive and label-free technique of EIS was used for quantification of IL 1 alpha concentration. Under optimum experimental conditions, the immunosensor had a good linear relationship between impedance values and the IL 1 alpha concentrations ranging from 0.01 to 2 pg/mL and from 0.01 to 3 pg/mL for LP(GMA) and CLP(GMA) modified ITO electrodes, respectively. The results confirmed that CLP(GMA) used in the preparation of the immunosensor illustrated improvements in immunosensor performance, comparing to the LP(GMA) modified immunosensor. Additionally, the immunosensor was successfully applied to evaluate human serum and saliva samples. The obtained results from these samples illustrated the feasibility of the immunosensor for clinical diagnosis in complex biological samples. Also, a simple and low-cost approach was attempted for development of immunosensor with remarkable performance characteristics. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:129 / 139
页数:11
相关论文
共 43 条
[1]   Diagnosis of dengue infection using a modified gold electrode with hybrid organic-inorganic nanocomposite and Bauhinia monandra lectin [J].
Andrade, Cesar A. S. ;
Oliveira, Maria D. L. ;
de Melo, Celso P. ;
Coelho, Luana C. B. B. ;
Correia, Maria T. S. ;
Nogueira, Mauricio L. ;
Singh, Pankaj R. ;
Zeng, Xiangqun .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2011, 362 (02) :517-523
[2]   Ultrasensitive determination of cadherin-like protein 22 with a label-free electrochemical immunosensor using brush type poly(thiophene-g-glycidylmethacrylate) modified disposable ITO electrode [J].
Aydin, Elif Burcu ;
Aydin, Muhammet ;
Sezginturk, Mustafa Kemal .
TALANTA, 2019, 200 :387-397
[3]   Electrochemical immunosensor based on chitosan/conductive carbon black composite modified disposable ITO electrode: An analytical platform for p53 detection [J].
Aydin, Elif Burcu ;
Aydin, Muhammet ;
Sezginturk, Mustafa Kemal .
BIOSENSORS & BIOELECTRONICS, 2018, 121 :80-89
[4]   Highly sensitive electrochemical immunosensor based on polythiophene polymer with densely populated carboxyl groups as immobilization matrix for detection of interleukin 1β in human serum and saliva [J].
Aydin, Elif Burcu ;
Aydin, Muhammet ;
Sezginturk, Mustafa Kemal .
SENSORS AND ACTUATORS B-CHEMICAL, 2018, 270 :18-27
[5]   A highly sensitive immunosensor based on ITO thin films covered by a new semi-conductive conjugated polymer for the determination of TNFα in human saliva and serum samples [J].
Aydin, Elif Burcu ;
Aydin, Muhammet ;
Sezginturk, Mustafa Kemal .
BIOSENSORS & BIOELECTRONICS, 2017, 97 :169-176
[6]   Electrochemical immunosensor for CDH22 biomarker based on benzaldehyde substituted poly(phosphazene) modified disposable ITO electrode: A new fabrication strategy for biosensors [J].
Aydin, Muhammet ;
Aydin, Elif Burcu ;
Sezginturk, Mustafa Kemal .
BIOSENSORS & BIOELECTRONICS, 2019, 126 :230-239
[7]   Genetic Polymorphisms of Interleukin-1 Alpha and the Vitamin D Receptor in Mexican Mestizo Patients with Intervertebral Disc Degeneration [J].
Cervin Serrano, Salvador ;
Gonzalez Villareal, Dalia ;
Aguilar-Medina, Maribel ;
Guillermo Romero-Navarro, Jose ;
Romero Quintana, Jose Geovanni ;
Arambula Meraz, Eliakym ;
Osuna Ramirez, Ignacio ;
Picos-Cardenas, Veronica ;
Granados, Julio ;
Estrada-Garcia, Iris ;
Sanchez-Schmitz, Guzman ;
Ramos-Payan, Rosalio .
INTERNATIONAL JOURNAL OF GENOMICS, 2014, 2014
[8]  
Chianeh YR, 2014, ASIAN PAC J TROP S1, V4, pS33
[9]   Multiplexed Point-of-Care Testing - xPOCT [J].
Dincer, Can ;
Bruch, Richard ;
Kling, Andre ;
Dittrich, Petra S. ;
Urban, Gerald A. .
TRENDS IN BIOTECHNOLOGY, 2017, 35 (08) :728-742
[10]   The interleukin 1 alpha, interleukin 1 beta, interleukin 6 and alpha-2-macroglobulin serum levels in patients with early or late onset Alzheimer's disease, mild cognitive impairment or Parkinson's disease [J].
Dursun, Erdinc ;
Gezen-Ak, Duygu ;
Hanagasi, Hasmet ;
Bilgic, Basar ;
Lohmann, Ebba ;
Ertan, Sibel ;
Atasoy, Irem L. ;
Alaylioglu, Merve ;
Araz, Omur Selin ;
Onal, Burak ;
Gunduz, Aysegul ;
Apaydin, Hulya ;
Kiziltan, Gunes ;
Ulutin, Turgut ;
Gurvit, Hakan ;
Yilmazer, Selma .
JOURNAL OF NEUROIMMUNOLOGY, 2015, 283 :50-57