MR fingerprinting with simultaneous T1, T2, and fat signal fraction estimation with integrated B0 correction reduces bias in water T1 and T2 estimates

被引:39
作者
Ostenson, Jason [1 ,2 ]
Damon, Bruce M. [1 ,2 ,3 ,4 ,5 ]
Welch, E. Brian [1 ,3 ,4 ]
机构
[1] Vanderbilt Univ, Inst Imaging Sci, Nashville, TN 37232 USA
[2] Vanderbilt Univ, Chem & Phys Biol Program, 221 Kirkland Hall, Nashville, TN 37235 USA
[3] Vanderbilt Univ, Dept Radiol & Radiol Sci, 221 Kirkland Hall, Nashville, TN 37235 USA
[4] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN 37235 USA
[5] Vanderbilt Univ, Dept Mol Physiol & Biophys, Nashville, TN 37232 USA
关键词
Magnetic resonance fingerprinting; Fat signal fraction; Adipose tissue; Static field heterogeneity; Relaxometry; RELAXATION-TIMES; MULTIFREQUENCY INTERPOLATION; LIVER; SEPARATION; QUANTIFICATION; RECONSTRUCTION; PULSES; ROBUST; TISSUE; BROWN;
D O I
10.1016/j.mri.2019.03.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: MR fingerprinting (MRF) sequences permit efficient T-1 and T-2 estimation in cranial and extracranial regions, but these areas may include substantial fat signals that bias T-1 and T-2 estimates. MRI fat signal fraction estimation is also a topic of active research in itself, but may be complicated by B-0 heterogeneity and blurring during spiral k-space acquisitions, which are commonly used for MRF. An MRF method is proposed that separates fat and water signals, estimates water T-1 and T-2, and accounts for B-0 effects with spiral blurring correction, in a single sequence. Theory and methods: A k-space-based fat-water separation method is further extended to unbalanced steady-state free precession MRF with swept echo time. Repeated application of this k-space fat-water separation to demodulated forms of the measured data allows a B-0 map and correction to be approximated. The method is compared with MRF without fat separation across a broad range of fat signal fractions (FSFs), water T(1)s and T(2)s, and under heterogeneous static fields in simulations, phantoms, and in vivo. Results: The proposed method's FSF estimates had a concordance correlation coefficient of 0.990 with conventional measurements, and reduced biases in the T-1 and T-2 estimates due to fat signal relative to other MRF sequences by several hundred ms. The B-0 correction improved the FSF, T-1, and T-2 estimation compared to those estimates without correction. Conclusion: The proposed method improves MRF water T-1 and T-2 estimation in the presence of fat and provides accurate FSF estimation with inline B-0 correction.
引用
收藏
页码:7 / 19
页数:13
相关论文
共 65 条
[1]   T2 mapping provides multiple approaches for the characterization of muscle involvement in neuromuscular diseases: a cross-sectional study of lower leg muscles in 5-15-year-old boys with Duchenne muscular dystrophy [J].
Arpan, Ishu ;
Forbes, Sean C. ;
Lott, Donovan J. ;
Senesac, Claudia R. ;
Daniels, Michael J. ;
Triplett, William T. ;
Deol, Jasjit K. ;
Sweeney, H. Lee ;
Walter, Glenn A. ;
Vandenborne, Krista .
NMR IN BIOMEDICINE, 2013, 26 (03) :320-328
[2]  
Bernstein M A, 2004, HDB MRI PULSE SEQUEN
[3]   What are normal relaxation times of tissues at 3 T? [J].
Bojorquez, Jorge Zavala ;
Bricq, Stephanie ;
Acquitter, Clement ;
Brunotte, Francois ;
Walker, Paul M. ;
Lalande, Alain .
MAGNETIC RESONANCE IMAGING, 2017, 35 :69-80
[4]   Generalized k-space decomposition with chemical shift correction for non-cartesian water-fat Imaging [J].
Brodsky, Ethan K. ;
Holmes, James H. ;
Yu, Huanzhou ;
Reeder, Scott B. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (05) :1151-1164
[5]   Histopathology of nonalcoholic fatty liver disease [J].
Brunt, Elizabeth M. ;
Tiniakos, Dina G. .
WORLD JOURNAL OF GASTROENTEROLOGY, 2010, 16 (42) :5286-5296
[6]   Spiral MR fingerprinting at 7 T with simultaneous B1 estimation [J].
Buonincontri, Guido ;
Schulte, Rolf F. ;
Cosottini, Mirco ;
Tosetti, Michela .
MAGNETIC RESONANCE IMAGING, 2017, 41 :1-6
[7]  
Cencici M, 2017, ISMRM WORK MRF
[8]   MR Fingerprinting for Rapid Quantitative Abdominal Imaging [J].
Chen, Yong ;
Jiang, Yun ;
Pahwa, Shivani ;
Ma, Dan ;
Lu, Lan ;
Twieg, Michael D. ;
Wright, Katherine L. ;
Seiberlich, Nicole ;
Griswold, Mark A. ;
Gulani, Vikas .
RADIOLOGY, 2016, 279 (01) :278-286
[9]   Multiparametric imaging with heterogeneous radiofrequency fields [J].
Cloos, Martijn A. ;
Knoll, Florian ;
Zhao, Tiejun ;
Block, Kai T. ;
Bruno, Mary ;
Wiggins, Graham C. ;
Sodickson, Daniel K. .
NATURE COMMUNICATIONS, 2016, 7
[10]   Computer programs for the concordance correlation coefficient [J].
Crawford, Sara B. ;
Kosinski, Andrzej S. ;
Lin, Hung-Mo ;
Williamson, John M. ;
Barnhart, Huiman X. .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2007, 88 (01) :62-74