Pu-239/Pu-240 isotope ratios determined using high resolution emission spectroscopy in a laser-induced plasma

被引:90
作者
Smith, CA [1 ]
Martinez, MA [1 ]
Veirs, DK [1 ]
Cremers, DA [1 ]
机构
[1] Los Alamos Natl Lab, Los Alamos, NM 87545 USA
关键词
laser-induced breakdown spectroscopy; Pu; isotope ratio; emission spectroscopy;
D O I
10.1016/S0584-8547(02)00023-X
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Laser-induced breakdown spectroscopy (LIBS) has been applied for the determination of plutonium isotope ratios through direct observation of atomic emission from laser-induced plasmas at high resolution. The Pu-239/Pu-240 isotope shift of -0.355 cm(-1) from the plutonium atomic line at 594.52202 nm (Blaise et al., The Atomic Spectrum of Plutonium, Argonne National Laboratory Report ANL-83-95, 1984) is clearly resolved in our plasma conditions. Atomic emission is dispersed through a 2-m spectrometer in double pass mode and collected on an electronically gated, intensified charge-coupled device (ICCD) camera. The integrated peak areas obtained from curve-fitting closely match the Pu-239/Pu-240 isotopic ratios obtained from standard methods of thermal ionization mass spectrometry and gamma spectrometry. The observed plutonium linewidths were 0.19 cm(-1) (0.0067 nm). These linewidths are within the experimental error of the ideal instrument-limited linewidth, which is calculated to be 0.15 cm(-1) (0.0052 nm) based upon the known modulation transfer function for the ICCD system. This linewidth should allow LIBS to be applicable for isotopic ratio measurements for all of the light actinides. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:929 / 937
页数:9
相关论文
共 16 条
[1]   High-resolution spectroscopy using an acousto-optic tunable filter and a fiber-optic Fabry-Perot interferometer [J].
Baldwin, DP ;
Zamzow, DS ;
DSilva, AP .
APPLIED SPECTROSCOPY, 1996, 50 (04) :498-503
[2]  
BLAISE J, 1984, ANL8395, P372
[3]  
Davies CM, 1996, FRESEN J ANAL CHEM, V355, P895
[4]   Determination of the first ionization potential of nine actinide elements by resonance ionization mass spectroscopy (RIMS) [J].
Erdmann, N ;
Nunnemann, M ;
Eberhardt, K ;
Herrmann, G ;
Huber, G ;
Kohler, S ;
Kratz, JV ;
Passler, G ;
Peterson, JR ;
Trautmann, N ;
Waldek, A .
JOURNAL OF ALLOYS AND COMPOUNDS, 1998, 271 :837-840
[5]   Determination of impurities in uranium and plutonium dioxides by laser-induced breakdown spectroscopy [J].
Fichet, P ;
Mauchien, P ;
Moulin, C .
APPLIED SPECTROSCOPY, 1999, 53 (09) :1111-1117
[6]   MTF evaluation of a phosphor-coated CCD for x-ray imaging [J].
Gambaccini, M ;
Taibi, A ;
DelGuerra, A ;
Marziani, M ;
Tuffanelli, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (12) :2799-2806
[7]   Evaluation of laser ablation optical emission spectrometry for microanalysis in aluminium samples [J].
Geertsen, C ;
Lacour, JL ;
Mauchien, P ;
Pierrard, L .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1996, 51 (11) :1403-1416
[8]  
GUNTUPALLI R, 2000, PRINCETON INSTRUMENT
[9]  
JOHANSSON S, 1991, J IMAGING SCI, V35, P320
[10]   NON-EQUILIBRIUM BEHAVIOR ON PULSED LASER EVAPORATED SURFACES [J].
LYNDS, L ;
WOODY, BA .
JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 1983, 29 (JAN) :147-153