Infrared Video Pupillography Coupled with Smart Phone LED for Measurement of Pupillary Light Reflex

被引:21
作者
Chang, Lily Yu-Li [1 ,2 ,3 ,4 ]
Turuwhenua, Jason [1 ,2 ,4 ]
Qu, Tian Yuan [1 ]
Black, Joanna M. [1 ,3 ,4 ]
Acosta, Monica L. [1 ,3 ,4 ]
机构
[1] Univ Auckland, Sch Optometry & Vis Sci, Fac Med & Hlth Sci, Auckland, New Zealand
[2] Univ Auckland, Auckland Bioengn Inst, Auckland, New Zealand
[3] Univ Auckland, Ctr Brain Res, Auckland, New Zealand
[4] Univ Auckland, New Zealand Natl Eye Ctr, Auckland, New Zealand
关键词
optometry; pupil light reflex; ophthalmology; autonomic nervous system; cholinergic deficiency; ALZHEIMERS-DISEASE; NERVOUS-SYSTEM;
D O I
10.3389/fnint.2017.00006
中图分类号
B84 [心理学]; C [社会科学总论]; Q98 [人类学];
学科分类号
03 ; 0303 ; 030303 ; 04 ; 0402 ;
摘要
Clinical assessment of pupil appearance and pupillary light reflex (PLR) may inform us the integrity of the autonomic nervous system (ANS). Current clinical pupil assessment is limited to qualitative examination, and relies on clinical judgment. Infrared (IR) video pupillography combined with image processing software offer the possibility of recording quantitative parameters. In this study we describe an IR video pupillography set-up intended for human and animal testing. As part of the validation, resting pupil diameter was measured in human subjects using the NeurOptics T (Irvine, CA, USA) pupillometer, to compare against that measured by our IR video pupillography set-up, and PLR was assessed in guinea pigs. The set-up consisted of a smart phone with a light emitting diode (LED) strobe light (0.2 s light ON, 5 s light OFF cycles) as the stimulus and an IR camera to record pupil kinetics. The consensual response was recorded, and the video recording was processed using a custom MATLAB program. The parameters assessed were resting pupil diameter (D1), constriction velocity (CV), percentage constriction ratio, re-dilation velocity (DV) and percentage re-dilation ratio. We report that the IR video pupillography set-up provided comparable results as the NeurOptics T pupillometer in human subjects, and was able to detect larger resting pupil size in juvenile male guinea pigs compared to juvenile female guinea pigs. At juvenile age, male guinea pigs also had stronger pupil kinetics for both pupil constriction and dilation. Furthermore, our IR video pupillography set-up was able to detect an age-specific increase in pupil diameter (female guinea pigs only) and reduction in CV (male and female guinea pigs) as animals developed from juvenile (3 months) to adult age (7 months). This technique demonstrated accurate and quantitative assessment of pupil parameters, and may provide the foundation for further development of an integrated system useful for clinical applications.
引用
收藏
页数:8
相关论文
共 24 条
[1]   LOSS OF NEURONS IN THE NUCLEUS BASALIS OF MEYNERT IN ALZHEIMERS-DISEASE, PARALYSIS AGITANS AND KORSAKOFFS DISEASE [J].
ARENDT, T ;
BIGL, V ;
ARENDT, A ;
TENNSTEDT, A .
ACTA NEUROPATHOLOGICA, 1983, 61 (02) :101-108
[2]   iPhones for eye surgeons [J].
Bastawrous, A. ;
Cheeseman, R. C. ;
Kumar, A. .
EYE, 2012, 26 (03) :343-354
[3]   Smartphone Fundoscopy [J].
Bastawrous, Andrew .
OPHTHALMOLOGY, 2012, 119 (02) :432-433
[4]   IMPAIRED SYMPATHETIC NERVOUS-SYSTEM RESPONSE TO COGNITIVE EFFORT IN EARLY ALZHEIMERS-DISEASE [J].
BORSON, S ;
BARNES, RF ;
VEITH, RC ;
HALTER, JB ;
RASKIND, MA .
JOURNALS OF GERONTOLOGY, 1989, 44 (01) :M8-M12
[5]   Mobile Phones to Improve the Practice of Neurology [J].
Busis, Neil .
NEUROLOGIC CLINICS, 2010, 28 (02) :395-+
[6]   A diagnostic challenge: dilated pupil [J].
Caglayan, Hale Z. Batur ;
Colpak, Ilksen A. ;
Kansu, Tulay .
CURRENT OPINION IN OPHTHALMOLOGY, 2013, 24 (06) :550-557
[7]   Alzheimer's disease in the human eye. Clinical tests that identify ocular and visual information processing deficit as biomarkers [J].
Chang, Lily Y. L. ;
Lowe, Jennifer ;
Ardiles, Alvaro ;
Lim, Julie ;
Grey, Angus C. ;
Robertson, Ken ;
Danesh-Meyer, Helen ;
Palacios, Adrian G. ;
Acosta, Monica L. .
ALZHEIMERS & DEMENTIA, 2014, 10 (02) :251-261
[8]   Gender difference in the miotic potency of soman vapor in rats [J].
Dabisch, Paul A. ;
Horsmon, Michael S. ;
Taylor, James T. ;
Muse, William T. ;
Miller, Dennis B. ;
Sommerville, Douglas R. ;
Mioduszewski, Robert J. ;
Thomson, Sandra .
CUTANEOUS AND OCULAR TOXICOLOGY, 2008, 27 (02) :123-133
[9]   Cholinergic deficiency in Alzheimer's and Parkinson's disease: Evaluation with pupillometry [J].
Fotiou, D. F. ;
Stergiou, V. ;
Tsiptsios, D. ;
Lithari, C. ;
Nakou, M. ;
Karlovasitou, A. .
INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 2009, 73 (02) :143-149
[10]   Automated standardized pupillometry with optical method for purposes of clinical practice and research [J].
Fotiou, F ;
Fountoulakis, KN ;
Goulas, A ;
Alexopoulos, L ;
Palikaras, A .
CLINICAL PHYSIOLOGY, 2000, 20 (05) :336-347