Automatic recognition of small cell carcinoma based on the self-organizing neural network

被引:0
作者
Li, FZ
Hu, KH
Su, WF
Li, SY
Cai, N
Huang, ZY
Hu, YX
机构
[1] Acad Sinica, Inst Biophys, Beijing 100101, Peoples R China
[2] Inst TB & Thorac Tumors, Pathol Lab, Beijing 101100, Peoples R China
[3] China Natl Software & Technol Co, Beijing 100081, Peoples R China
关键词
recognition of SCC; SOFM; neural network; mathematical morphology; colorimetry;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this paper the recognition of Small Cell Carcinoma (SCC) is studied. For each type we select 128 samples for training, and randomly measure 200 cells in each sample. We introduce multi-scale morphology based on centroid coordinates to extract the boundaries of nuclei and obtain feature images of nuclei. The features of lung cancer cells are described by morphological and colorimetrical parameters, which is valuable to recognize SCC. Then the architecture of self-organizing feature mapping (SOFM) neural network is studied for recognition of SCC. The weights of the network are adjusted by self-organizing competition, and finally inputted patterns are classified. This algorithm has the advantage of parallelism and fast-convergence, and may simplify the analysis of SCC. Clinical experiment results show that the correctness ratio of this system may reach 95.3% while recognizing lung cancer cell types. Our work is significant to the pathological researches of lung cancer, assistant clinic diagnosis, and assessment of therapeutic effects. Meanwhile a software system named as SCC.LUNG is established for automatic analysis.
引用
收藏
页码:175 / 184
页数:10
相关论文
共 18 条
  • [1] BAAK JPA, 1991, MANUAL DIAGNOSTIC MO, P1
  • [2] Clinical epidemiological quality in molecular genetic research - The need for methodological standards
    Bogardus, ST
    Concato, J
    Feinstein, AR
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1999, 281 (20): : 1919 - 1926
  • [3] A MASSIVELY PARALLEL ARCHITECTURE FOR A SELF-ORGANIZING NEURAL PATTERN-RECOGNITION MACHINE
    CARPENTER, GA
    GROSSBERG, S
    [J]. COMPUTER VISION GRAPHICS AND IMAGE PROCESSING, 1987, 37 (01): : 54 - 115
  • [4] CHEN CH, 1989, SPIE, V1192, P339
  • [5] THE POOR QUALITY OF EARLY EVALUATIONS OF MAGNETIC-RESONANCE IMAGING
    COOPER, LS
    CHALMERS, TC
    MCCALLY, M
    BERRIER, J
    SACKS, HS
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1988, 259 (22): : 3277 - 3280
  • [6] Harvey NR, 1996, COMP IMAG VIS, P179
  • [7] Methodologic standards for diagnostic test research in pulmonary medicine
    Heffner, JE
    Feinstein, D
    Barbieri, C
    [J]. CHEST, 1998, 114 (03) : 877 - 885
  • [8] JING QC, 1997, COLORIMETRY, P1
  • [9] KOHONEN T, 1984, SELF ORG MAPS ASS ME
  • [10] KOSKINEN JA, 1991, SPIE S IM ALG MORPH, V2, P262