Comparison of reflectometric interference spectroscopy with other instruments for label-free optical detection

被引:88
作者
Hänel, C [1 ]
Gauglitz, G [1 ]
机构
[1] Univ Tubingen, Inst Phys & Theoret Chem, D-72076 Tubingen, Germany
关键词
label-free detection; reflectometric interference spectroscopy; biomolecular interaction; thrombine; thrombine inhibitor;
D O I
10.1007/s00216-001-1197-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
On the basis of kinetic measurements of biomolecular interactions, a reflectometric interference spectroscopy (RIfS) setup is compared with two commercial instruments. These instruments are based on evanescent wave techniques, surface plasmon resonance (SPR) (represented by BlAcore 2000) and resonant mirror (RM) technique (using IAsys plus). All methods allow a label-free and time-resolved optical detection of biomolecular interaction. These methods are mainly used in biomolecular interaction analysis (BIA). They provide practical techniques for quantifying equilibrium constants and rate constants over several orders of magnitude. The general parameters of the three detectors, namely baseline noise and drift as well as overall sensitivity and limits of detection were compared. The fluid handling and the related implications on the measurements have also been considered. The interaction between thrombine and thrombine inhibitor (TI) was investigated as a test system with the three different methods and the kinetic rate constants were determined and compared. For this TI was immobilized on the surface and binding of thrombine was monitored time-resolved. Determination of the kinetic rate constants could prove that the RIfS set-up is comparable with SPR using BlAcore 2000 and RM technique represented by IAsys plus.
引用
收藏
页码:91 / 100
页数:10
相关论文
共 32 条
[1]   SCREENING AND KINETIC-ANALYSIS OF RECOMBINANT ANTI-CEA ANTIBODY FRAGMENTS [J].
ABRAHAM, R ;
BUXBAUM, S ;
LINK, J ;
SMITH, R ;
VENTI, C ;
DARSLEY, M .
JOURNAL OF IMMUNOLOGICAL METHODS, 1995, 183 (01) :119-125
[2]  
*AFF SENS, 1996, IAS METH GUID
[3]  
BALTES H, 1996, SENSORS UPDATE SENSO, V1
[4]   OPTIMIZED LAYER SYSTEMS FOR IMMUNOSENSORS BASED ON THE RIFS TRANSDUCER [J].
BRECHT, A ;
GAUGLITZ, G .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 349 (05) :360-366
[5]   INTERFEROMETRIC IMMUNOASSAY IN A FIA-SYSTEM - A SENSITIVE AND RAPID APPROACH IN LABEL-FREE IMMUNOSENSING [J].
BRECHT, A ;
GAUGLITZ, G ;
POLSTER, J .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (7-8) :387-392
[6]   Recent developments in optical transducers for chemical or biochemical applications [J].
Brecht, A ;
Gauglitz, G .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 38 (1-3) :1-7
[7]   OPTICAL PROBES AND TRANSDUCERS [J].
BRECHT, A ;
GAUGLITZ, G .
BIOSENSORS & BIOELECTRONICS, 1995, 10 (9-10) :923-936
[8]   A MICROSCALE METHOD EMPLOYING SURFACE-PLASMON RESONANCE DETECTION FOR THE DETERMINATION OF CONDITIONS FOR IMMUNOAFFINITY CHROMATOGRAPHY OF PROTEINS [J].
BRIGHAMBURKE, M ;
OSHANNESSY, DJ .
CHROMATOGRAPHIA, 1993, 35 (1-2) :45-49
[9]   THE RESONANT MIRROR - A NOVEL OPTICAL BIOSENSOR FOR DIRECT SENSING OF BIOMOLECULAR INTERACTIONS .1. PRINCIPLE OF OPERATION AND ASSOCIATED INSTRUMENTATION [J].
CUSH, R ;
CRONIN, JM ;
STEWART, WJ ;
MAULE, CH ;
MOLLOY, J ;
GODDARD, NJ .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (7-8) :347-353
[10]  
Cussler E. L., 1984, DIFFUSION MASS TRANS