Stent-Assisted Coil Embolization of Posterior Communicating Artery Aneurysms

被引:21
|
作者
Cho, Y. D. [1 ]
Lee, W. J. [1 ]
Kim, K. M. [1 ]
Kang, H. -S. [2 ]
Kim, J. E. [2 ]
Han, M. H. [1 ,2 ]
机构
[1] Seoul Natl Univ, Seoul Natl Univ Hosp, Coll Med, Dept Radiol, Seoul 110744, South Korea
[2] Seoul Natl Univ, Seoul Natl Univ Hosp, Coll Med, Dept Neurosurg, Seoul 110744, South Korea
关键词
INITIAL CLINICAL-EXPERIENCE; INFERIOR CEREBELLAR ARTERY; EXPANDING NITINOL STENT; INTRACRANIAL ANEURYSMS; ENDOVASCULAR TREATMENT; CEREBRAL ANEURYSMS; DETACHABLE COILS; ENTERPRISE; NEUROFORM;
D O I
10.3174/ajnr.A3541
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Use of protective stents may not be effective in coil embolization of wide-neck aneurysms involving the posterior communicating artery. Successful implementation depends on the caliber of the vessel, its angle of origin, and the manner in which its orifice is incorporated into the aneurysm. Presented here are the results (clinical and radiographic) of coil embolization in aneurysms of the ICA-posterior communicating artery junction, variably aided by stents. The primary focus is angiographic configurations that impact stent placement. MATERIALS AND METHODS: From a prospective data repository, we retrieved records of 32 consecutive patients with 33 posterior communicating artery aneurysms, all of which were treated by stent-assisted coil embolization between June 2008 and August 2012. Outcomes were analyzed in terms of aneurysm configuration and clinical status. RESULTS: Stents were positioned entirely in the ICA (n = 26), from the ICA to the posterior communicating artery (n = 2), in the posterior communicating artery only (n = 3), and retrograde from the posterior communicating artery to the ICA terminus (n = 2). Procedure-related complications occurred in 3 patients (9.1%), but only 1 (3.0%) had mild neurologic sequelae (Glasgow Outcome Score 4). Using coil embolization, we achieved successful occlusion in 24 aneurysms (72.7%), and in 9 others, subtotal occlusion was conferred. During a mean follow-up of 15.7 10.7 months, imaging of 27 aneurysms documented stable occlusion in 19 (70.4%), whereas angiography of 15 aneurysms (39.5%) disclosed 2 instances of in-stent stenosis (13.3%) and a solitary occurrence of stent migration (6.7%). CONCLUSIONS: In posterior communicating artery aneurysms, stent protection during coil embolization is feasible by adjusting the procedural strategy to accommodate differing configurations of the aneurysm and its vascular source.
引用
收藏
页码:2171 / 2176
页数:6
相关论文
共 50 条
  • [41] Stent-Assisted Embolization of Wide-Neck Anterior Communicating Artery Aneurysms: Review of 21 Consecutive Cases
    Huang, Q.
    Xu, Y.
    Hong, B.
    Zhao, R.
    Zhao, W.
    Liu, J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (08) : 1502 - 1506
  • [42] Overlapping stent-assisted coil embolization for vertebrobasilar dissecting aneurysms: a single-center study
    Shi, Guangyao
    Xu, Shancai
    Gareev, Ilgiz
    Ji, Zhiyong
    Pei, Wu
    Zhang, Guang
    Qi, Jingtao
    Chen, Rui
    Liang, Shaodong
    Gu, Yan
    Wang, Chunlei
    NEUROLOGICAL RESEARCH, 2021, 43 (09) : 701 - 707
  • [43] Endovascular Enterprise stent-assisted coil embolization for wide-necked unruptured intracranial aneurysms
    Hwang, Sung-Kyun
    Hwang, Gyojun
    Bang, Jae Seung
    Oh, Chang Wan
    Kwon, O-Ki
    JOURNAL OF CLINICAL NEUROSCIENCE, 2013, 20 (09) : 1276 - 1279
  • [44] Hemodynamic Effects of Stent Struts versus Straightening of Vessels in Stent-Assisted Coil Embolization for Sidewall Cerebral Aneurysms
    Kono, Kenichi
    Shintani, Aki
    Terada, Tomoaki
    PLOS ONE, 2014, 9 (09):
  • [45] Treatment of blood blister-like aneurysms of the internal stent-assisted coil embolization
    Fang, Yi-Bin
    Li, Qiang
    Yang, Peng-Fei
    Huang, Qing-Hai
    Zhao, Wen-Yuan
    Xu, Yi
    Hong, Bo
    Liu, Jian-Min
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2013, 115 (07) : 920 - 925
  • [46] Transbrachial stent-assisted coil embolization of right posterior inferior cerebellar artery aneurysm: Technical case report
    Zaidat, Osama O.
    Szeder, Viktor
    Alexander, Michael J.
    JOURNAL OF NEUROIMAGING, 2007, 17 (04) : 344 - 347
  • [47] No differences in effectiveness and safety between pipeline embolization device and stent-assisted coiling for the treatment of communicating segment internal carotid artery aneurysms
    Enriquez-Marulanda, Alejandro
    Salem, Mohamed M.
    Ascanio, Luis C.
    Maragkos, Georgios A.
    Gupta, Raghav
    Moore, Justin M.
    Thomas, Ajith J.
    Ogilvy, Christopher S.
    Alturki, Abdulrahman Y.
    NEURORADIOLOGY JOURNAL, 2019, 32 (05) : 344 - 352
  • [48] Stent-Assisted Coil Embolization for Ruptured Intracranial Dissecting Aneurysms Involving Essential Vessels
    Hosogai, Masahiro
    Matsushige, Toshinori
    Shimonaga, Koji
    Kawasumi, Omohiro
    Kurisu, Kaoru
    Sakamoto, Shigeyuki
    WORLD NEUROSURGERY, 2018, 119 : E728 - E733
  • [49] Stability of Cerebral Aneurysms After Stent-Assisted Coil Embolization: A Propensity Score-Matched Analysis
    Cho, Won-Sang
    Hong, Hyun Sook
    Kang, Hyun-Seung
    Kim, Jeong Eun
    Cho, Young Dae
    Kwon, O-Ki
    Bang, Jae Seung
    Hwang, Gyojun
    Son, Young Je
    Oh, Chang Wan
    Han, Moon Hee
    NEUROSURGERY, 2015, 77 (02) : 208 - 216
  • [50] Stent-assisted coil embolization followed by a stent-within-a-stent technique for ruptured dissecting aneurysms of the intracranial vertebrobasilar artery Clinical article
    Suh, Sang Hyun
    Kim, Byung Moon
    Park, Sung Il
    Kim, Dong Ik
    Shin, Yong Sam
    Kim, Eui Jong
    Chung, Eun Chul
    Koh, Jun Seok
    Shin, Hyun Cheol
    Choi, Chun Sik
    Won, Yu Sam
    JOURNAL OF NEUROSURGERY, 2009, 111 (01) : 48 - 52