Parameter Optimization of the LC filters Based on Multiple Impact Factors for Cascaded H-bridge Dynamic Voltage Restorers

被引:4
作者
Chen, Guodong [1 ,2 ]
Zhu, Miao [1 ]
Cai, Xu [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Elect Informat & Elect Engn, Wind Power Res Ctr, Key Lab Control Power Transmiss & Transformat, Shanghai 200030, Peoples R China
[2] Technol Ctr, Shanghai Elect Power Transmiss & Distribut Grp, Shanghai, Peoples R China
关键词
Dynamic Voltage Restorer; Multiple Impact Factors; Parameter Optimization; Value Range Function; DESIGN; SYSTEM; SAG;
D O I
10.6113/JPE.2014.14.1.165
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The cascaded H-Bridge Dynamic Voltage Restorer (DVR) is used for protecting high voltage and large capacity loads from voltage sags. The LC filter in the DVR is needed to eliminate switching ripples, which also provides an accurate tracking feature in a certain frequency range. Therefore, the parameter optimization of the LC filter is especially important. In this paper, the value range functions for the inductance and capacitance in LC filters are discussed. Then, parameter variations under different conditions of voltage sags and power factors are analyzed. In addition, an optimized design method is also proposed with the consideration of multiple impact factors. A detailed optimization procedure is presented, and its validity is demonstrated by simulation and experimental results. Both results show that the proposed method can improve the LC filter design for a cascaded H-Bridge DVR and enhance the performance of the whole system.
引用
收藏
页码:165 / 174
页数:10
相关论文
共 20 条
[1]  
[Anonymous], P 7 INT C EL EL ENG
[2]  
Fernandes D. A., 2008, 2008 IEEE International Symposium on Industrial Electronics (ISIE 2008), P80, DOI 10.1109/ISIE.2008.4677111
[3]   Voltage sag and recovery time in repetitive events [J].
Gómez, JC ;
Morcos, MM .
IEEE TRANSACTIONS ON POWER DELIVERY, 2002, 17 (04) :1037-1043
[4]  
Guo SX, 2011, APPL POWER ELECT CO, P1599, DOI 10.1109/APEC.2011.5744808
[5]   A design consideration of output filters for dynamic voltage restorers [J].
Kim, H ;
Kim, JH ;
Sul, SK .
PESC 04: 2004 IEEE 35TH ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, CONFERENCE PROCEEDINGS, 2004, :4268-4272
[6]   Cascaded Multicell Trans-Z-Source Inverters [J].
Li, Ding ;
Loh, Poh Chiang ;
Zhu, Miao ;
Gao, Feng ;
Blaabjerg, Frede .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (02) :826-836
[7]  
[刘春喜 Liu Chunxi], 2011, [电工技术学报, Transactions of China Electrotechnical Society], V26, P129
[8]   Optimized Control Strategy for a Medium-Voltage DVR-Theoretical Investigations and Experimental Results [J].
Meyer, Christoph ;
De Doncker, Rik W. ;
Li, Yun Wei ;
Blaabjerg, Frede .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2008, 23 (06) :2746-2754
[9]   A detailed comparison of system topologies for dynamic voltage restorers [J].
Nielsen, JG ;
Blaabjerg, F .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2005, 41 (05) :1272-1280
[10]  
Papic I., 1999, 1999 IEEE Power Engineering Society Summer Meeting. Conference Proceedings (Cat. No. 99CH36364), P1214, DOI 10.1109/PESS.1999.787491