Review of simulation modeling for shading devices in buildings

被引:233
作者
Kirimtat, Ayca [1 ]
Koyunbaba, Basak Kundakci [1 ]
Chatzikonstantinou, Ioannis [1 ]
Sariyildiz, Sevil [1 ]
机构
[1] Yasar Univ, Fac Architecture, Izmir, Turkey
关键词
Solar shading device; Simulation modeling; Simulation tools; Buildings; DOUBLE SKIN FACADE; THERMAL PERFORMANCE; VENETIAN BLIND; ENERGY-CONSUMPTION; NATURAL VENTILATION; CONTROL STRATEGIES; OFFICE BUILDINGS; GLAZED FACADE; DESIGN; WINDOW;
D O I
10.1016/j.rser.2015.08.020
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Many countries around the world are confronted with the challenge of decreasing energy consumption, while the use of electrical appliances is continuously increasing in buildings. The requirement to minimize the energy consumption can be fulfilled by revaluating architectural aspects. One of these aspects is related to overheating problems, caused by facades with large, glazed portions. In such designs, shading elements must carefully be integrated and considered at an early-design stage in the design process. Shading of buildings is crucial especially in climates with hot summer. It is significant to protect the window from solar radiation in summer while allowing maximum solar radiation in winter. For this reason, precise figures of their performance are needed. As such, simulation tools are often used for identifying the most suitable shading element that suits the building. In literature, there are many studies that have been done to designate the energy performance of shading devices in buildings by using simulation tools. This study focuses both on the shading device types used in the building sector and the previous studies done for designating the performance aspects of different shading devices types. Numerous studies for different building types located in different climatic regions have been reviewed in order to underline the importance of simulation modeling for shading devices in buildings. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:23 / 49
页数:27
相关论文
共 109 条
[1]   The approach to daylighting by scale models and sun and sky simulators: A case study for different shading systems [J].
Agherno, C. ;
Pellegrino, A. ;
LoVerso, V. R. M. .
BUILDING AND ENVIRONMENT, 2008, 43 (05) :917-927
[2]   The potential of shading devices for temperature reduction in high-rise residential buildings in the tropics [J].
Al-Tamimi, Nedhal A. ;
Fadzil, Sharifah Fairuz Syed .
2011 INTERNATIONAL CONFERENCE ON GREEN BUILDINGS AND SUSTAINABLE CITIES, 2011, 21 :273-282
[3]   Conventional fixed shading devices in comparison to an electrochromic glazing system in hot, dry climate [J].
Aldawoud, Abdelsalam .
ENERGY AND BUILDINGS, 2013, 59 :104-110
[4]   Using simulation for studying the influence of horizontal shading device protrusion on the thermal performance of spaces in residential buildings [J].
Ali, Ahmed AbdelMonteleb Mohammed .
ALEXANDRIA ENGINEERING JOURNAL, 2013, 52 (04) :787-796
[5]   Using simulation for studying the influence of vertical shading devices on the thermal performance of residential buildings (Case study: New Assiut City) [J].
Ali Ahmed, Ahmed Abd El-Monteleb Mohammed .
AIN SHAMS ENGINEERING JOURNAL, 2012, 3 (02) :163-174
[6]   Assessment of building facade performance in terms of daylighting and the associated energy consumption in architectural spaces: Vertical and horizontal shading devices for southern exposure facades [J].
Alzoubi, Hussain H. ;
Al-Zoubi, Amneh H. .
ENERGY CONVERSION AND MANAGEMENT, 2010, 51 (08) :1592-1599
[7]  
[Anonymous], SOL SHAD
[8]   An hourly based performance comparison of an integrated micro-structural perforated shading screen with standard shading systems [J].
Appelfeld, David ;
McNeil, Andrew ;
Svendsen, Svend .
ENERGY AND BUILDINGS, 2012, 50 :166-176
[9]  
Architecture LE, 2001, OPT OR AUT CONTR EXT, P7
[10]   Comparative energy and economic performance analysis of an electrochromic window and automated external venetian blind [J].
Aste, Niccolo ;
Compostella, Junia ;
Mazzon, Manlio .
1ST INTERNATIONAL CONFERENCE ON SOLAR HEATING AND COOLING FOR BUILDINGS AND INDUSTRY (SHC 2012), 2012, 30 :404-413