Prospective motion correction in functional MRI using simultaneous multislice imaging and multislice-to-volume image registration

被引:16
作者
Hoinkiss, Daniel Christopher [1 ]
Erhard, Peter [1 ,2 ]
Breutigam, Nora-Josefin [1 ]
van Samson-Himmelstjerna, Federico [1 ]
Guenther, Matthias [1 ,2 ]
Porter, David Andrew [3 ]
机构
[1] Fraunhofer Inst Digital Med MEVIS, Bremen, Germany
[2] Univ Bremen, Bremen, Germany
[3] Univ Glasgow, Coll Med Vet & Life Sci, Imaging Ctr Excellence, Glasgow, Lanark, Scotland
关键词
Prospective motion correction; Simultaneous multislice (SMS); Multislice-to-volume; Image registration; EPI; Functional MRI; Real-time MRI sequences; BOLD; Kalman filter; HUMAN BRAIN; ARTIFACT REDUCTION; TIME; EPI; ACQUISITION; TRACKING; PET; CT;
D O I
10.1016/j.neuroimage.2019.06.042
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The sensitivity to subject motion is one of the major challenges in functional MRI (fMRI) studies in which a precise alignment of images from different time points is required to allow reliable quantification of brain activation throughout the scan. Especially the long measurement times and laborious fMRI tasks add to the amount of subject motion found in typical fMRI measurements, even when head restraints are used. In case of moving subjects, prospective motion correction can maintain the relationship between spatial image information and subject anatomy by constantly adapting the image slice positioning to follow the subject in real time. Image-based prospective motion correction is well-established in fMRI studies and typically computes the motion estimates based on a volume-to-volume image registration, resulting in low temporal resolution. This study combines fMRI using simultaneous multislice imaging with multislice-to-volume-based image registration to allow sub-TR motion detection with subsequent real-time adaption of the imaging system. Simultaneous multislice imaging is widely used in fMRI studies and, together with multislice-to-volume-based image registration algorithms, enables computing suitable motion states after only a single readout by registering the simultaneously excited slices to a reference volume acquired at the start of the measurement. The technique is evaluated in three human BOLD fMRI studies (n = 1, 5, and 1) to explore different aspects of the method. It is compared to conventional, volume-tovolume-based prospective motion correction as well as retrospective motion correction methods. Results show a strong reduction in retrospectively computed residual motion parameters of up to 50% when comparing the two prospective motion correction techniques. An analysis of temporal signal-to-noise ratio as well as brain activation results shows high consistency between the results before and after additional retrospective motion correction when using the proposed technique, indicating successful prospective motion correction. The comparison of absolute tSNR values does not show an improvement compared to using retrospective motion correction alone. However, the improved temporal resolution may provide improved tSNR in the presence of more exaggerated intra-volume motion.
引用
收藏
页码:159 / 173
页数:15
相关论文
共 45 条
  • [1] Real-Time Optical Motion Correction for Diffusion Tensor Imaging
    Aksoy, Murat
    Forman, Christoph
    Straka, Matus
    Skare, Stefan
    Holdsworth, Samantha
    Hornegger, Joachim
    Bammer, Roland
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (02) : 366 - 378
  • [2] Susceptibility-induced distortion that varies due to motion: Correction in diffusion MR without acquiring additional data
    Andersson, Jesper L. R.
    Graham, Mark S.
    Drobnjak, Ivana
    Zhang, Hui
    Campbell, Jon
    [J]. NEUROIMAGE, 2018, 171 : 277 - 295
  • [3] [Anonymous], 2007, STAT PARAMETRIC MAPP, DOI DOI 10.1016/B978-0-12-372560-8.X5000-1
  • [4] TIME COURSE EPI OF HUMAN BRAIN-FUNCTION DURING TASK ACTIVATION
    BANDETTINI, PA
    WONG, EC
    HINKS, RS
    TIKOFSKY, RS
    HYDE, JS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1992, 25 (02) : 390 - 397
  • [5] SimPACE: Generating simulated motion corrupted BOLD data with synthetic-navigated acquisition for the development and evaluation of SLOMOCO: A new, highly effective slicewise motion correction
    Beall, Erik B.
    Lowe, Mark J.
    [J]. NEUROIMAGE, 2014, 101 : 21 - 34
  • [6] Real-time RF pulse adjustment for B0 drift correction
    Benner, Thomas
    van der Kouwe, Andre J. W.
    Kirsch, John E.
    Sorensen, A. Gregory
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (01) : 204 - 209
  • [7] HEAD HOLDER FOR PET, CT, AND MR STUDIES
    BETTINARDI, V
    SCARDAONI, R
    GILARDI, MC
    RIZZO, G
    PERANI, D
    PAULESU, E
    STRIANO, G
    TRIULZI, F
    FAZIO, F
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (05) : 886 - 892
  • [8] Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) for multi-slice imaging
    Breuer, FA
    Blaimer, M
    Heidemann, RM
    Mueller, MF
    Griswold, MA
    Jakob, PM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (03) : 684 - 691
  • [9] General Formulation for Quantitative G-factor Calculation in GRAPPA Reconstructions
    Breuer, Felix A.
    Kannengiesser, Stephan A. R.
    Blaimer, Martin
    Seiberlich, Nicole
    Jakob, Peter M.
    Griswold, Mark A.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (03) : 739 - 746
  • [10] Interslice Leakage Artifact Reduction Technique for Simultaneous Multislice Acquisitions
    Cauley, Stephen F.
    Polimeni, Jonathan R.
    Bhat, Himanshu
    Wald, Lawrence L.
    Setsompop, Kawin
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (01) : 93 - 102